EB 3135-2 EN
37
Annex
9 Annex
9.1 After-sales service
Contact SAMSON's After-sales Service for
support concerning service or repair work or
when malfunctions or defects arise.
E-mail address
You can reach our after-sales service at
[email protected].
Addresses of SAMSON AG and its subsid
-
iaries
The addresses of SAMSON, its subsidiaries,
representatives and service facilities
worldwide can be found on our website
(
u
www.samsongroup.com) or in all
SAMSON product catalogs.
To assist diagnosis and in case of an unclear
mounting situation, specify the following de-
tails (so far as possible). See section 2:
− Device type and valve size
− Model number and configuration ID
−
Upstream and downstream pressure
−
Temperature
− Min. and max. flow rate
−
Is a strainer installed?
−
Installation drawing showing the exact
location of the regulator and all the ad-
ditionally installed components (shut-off
valves, pressure gauge etc.)
9.2 Tightening torques
Part
Valve size
Tightening
torque in Nm
Coupling nut
(1.2)
DN 15
200
DN 20
250
DN 25
300
DN 32
400
DN 40
600
DN 50
800
Coupling nut (7)
All
20
Screw joint with
restriction (11.1)
All
22
Screw fitting
(11.2)
All
22
Содержание 2489/58 Series
Страница 39: ...EB 3135 2 EN 39 Certificates 1...
Страница 43: ...EB 3135 2 EN 43 Certificates 3...