14
EB 2183 EN
Design and principle of operation
Table 1:
Technical data · All pressures (gauge)
Type 2403 Safety Temperature Monitor
Port
M32x1.5
Adjustment range of limit value
60 to 75 °C · 75 to 100 °C
Permissible ambient temperature
Max. 50 °C
Perm. temperature at the sensor
25 K above the adjusted limit
Perm. pressure at sensor
25 bar
Capillary tube length
5 m
Conformity
Table 2:
Dimensions in mm
Table 2.1
Type 2432/2403 · Type 2433/2403 · Type 2436/2403 · Type 2437/2403
Valve size
DN
15
20
25
32
40
50
Pipe Ød
d
21.3
26.8
32.7
42
48
60
AF
30
36
46
59
65
82
Length
L
65
70
75
100
110
130
With welding ends
L1
210
234
244
268
294
330
With threaded ends
L2
129
144
159
180
196
228
With flanges
L3
130
150
160
180
200
230
Male thread
A
G ½
G ¾
G 1
G 1¼
G 1½
G 2
Type 2432/2403
H
140
190
H1
30
55
Type 2433/2403
H
135
145
H2
112
122
124
144
157
165
H3
72
77
82
100
108
114
H4
72
80
82
105
110
115
Type 2436/2403
H
–
160
H1
–
95
Type 2437/2403
H
220
270
H1
30
55