24
EB 2559 EN
Start-up and operation
6.2
Installing the regulator
Î
1. Close the shut-off valves (6.1 and 6.2) in
the pipeline while the valve is being in
-
stalled.
2. Take the regulator out of the packaging.
3. Lift the regulator to the site of installation.
Observe the flow direction through the
regulator. Markings on the regulator in
-
dicate the direction of installation.
4. Bolt the regulator to the pipeline free of
stress.
5. Slowly open the shut-off valves in the
pipeline after the regulator has been in
-
stalled.
6
Start-up and operation
6.1
Start-up
Re
Risk of personal injury due to process me-
dium escaping under pressure.
−
First start up the regulator after mounting
all parts.
Explosion hazard due to the use of oil and
grease in oxygen atmospheres!
Make sure that the regulator is absolutely
clean and free of oil and grease on installing
it.
Risk of burn injuries due to hot or very cold
components and pipelines.
Depending on the process medium, regula-
tor components and pipelines may get very
hot or cold and cause burn injuries.
Wear protective clothing and safety gloves.
Once installed in the pipeline, the regulator
can be put into operation.
DANGER
!
WARNING
!
WARNING
!