background image

DS-4

SDI switcher 4x1

Copyright © 1999 - 2014 Sams elektronik d.o.o.

Published: 15. january 2006.

Updated: 29. october 2014.

Z10-3 edition 1

Code: 002.100

ENGLISH

Sams elektronik d.o.o.

48 Zivka Davidovica st.

11050 Belgrade

Serbia

Tel/Fax: +381 11 3806 253 

+381 11 2402 212

[email protected]

www.sams.rs

USER MANUAL FOR USE AND MAINTENANCE

Read the instructions before using the device.

Keep this manual for periodic usage.

Содержание 002.100

Страница 1: ...9 october 2014 Z10 3 edition 1 Code 002 100 ENGLISH Sams elektronik d o o 48 Zivka Davidovica st 11050 Belgrade Serbia Tel Fax 381 11 3806 253 381 11 2402 212 sams sams rs www sams rs USER MANUAL FOR USE AND MAINTENANCE Read the instructions before using the device Keep this manual for periodic usage ...

Страница 2: ...er servicer has not completed repair or replacement within a reasonable time or if the manufacturer servicer did not perform repair or replacement without significant inconvenience to the consumer 5 The consumer may not terminate the contract if the lack of conformity of the product is negligible 6 The product will function properly when used in accordance with the user manual 7 Period of servicin...

Страница 3: ... voltage In poor conditions the user may be exposed to shock The symbol exclamation mark in a triangle is to alert the user to comply by the terms of use in user s manual which is supplied with the device SAFETY WARNINGS ELECTRICAL SHOCK HAZARD DO N OT O PEN CAUTION RIZIK OD S TRUJNOG UDARA NE O TVARATI DOK JE P OD N APONOM UPOZORENJE CLASS I DEVICE Grounding is connected to the chassis of the dev...

Страница 4: ... is equipped with a protective fuse in the power outlet Do not bypass fuse 12 Do not replace the fuse Replacement can be made by a person authorized by the manufacturer 13 Do not bend the power cord so that it can be damaged 14 Connect connectors as in the enclosed instructions Deviations from the allowed values predicted for the inputs and outputs of the device can cause severe damage and warrant...

Страница 5: ... sams rs www sams rs elektronik 5 UNPACKING AND INSTALLATION 6 MAINTENANCE 6 REMOVAL AND STORAGE 6 DESCRIPTION 7 INSTALLATION 8 CABLE CONNECTION BETWEEN SWITCHER AND REMOTE 8 REMOTE CONTROL SCU 4 9 NOTES 10 Page Description TABLE OF CONTENTS ...

Страница 6: ...ckage it in a box 5 The device must be stored in a room without moisture The system maintains only person authorized by Sams elektronik doo Any voluntarily opening device upgrading or servicing is strictly prohibited and is subject to warranty void and the possibility of injury Places for fastening PROCEDURES FOR SAFE USE OF THE DEVICE 1 Remove the protective wrap from the chassis For devices that...

Страница 7: ...nal type SDI per SMPTE 259 EQ Automatic to 100m with Belden 1694A cable Impedance 75Ω Connectors BNC OUTPUT Number 1 dual Connectors BNC Impedance 75Ω Output level 800mV 10 Jitter 0 2UI at 10Hz Delay 15μs typical BLOCK DIAGRAM ORDERING INFORMATION Code Name Description 002 100 DS 4 SDI switcher 4x1 002 501 SCU 4L Remote control 4x1 Specifications and designs are subject to change without notice DS...

Страница 8: ...ct the power cord The device works only on AC 230 V 50 Hz Connect all necessary connectors before the unit is turned on Turn on the device by pressing power switch video inputs video output connection with remote control DS 4 rear side Buttons to select an input Remote control SCU 4 front side DS 4 front side 1 2 3 4 5 6 7 8 9 P1A P1A P1A P2B P2B P2B GND GND V V 1 3 3 1 579 2468x muski SUB D9P 1 5...

Страница 9: ...DS Switchers Sams elektronik d o o sams sams rs www sams rs elektronik 9 REMOTE CONTROL SCU 4 The connection to the switcher ...

Страница 10: ...DS Switchers elektronik Sams elektronik d o o sams sams rs www sams rs 10 NOTES ...

Отзывы: