EMF829 ElectroSmog Instruction Manual

 

I.

 

Safety Instructions 

   

 

  Notes

 

1. Before measurement, Please check if the low power symbol (

) is displayed. If it 

is displayed please replace the batteries. 

2. Turn OFF the instrument and remove the battery when not in use for a long time. 

3.  When  the  electric  field  device  is  connected  to  the  meter,  please  don’t  vibrate  the  meter 

especially in measuring. 

4.  The  outside  environment  and  unsuitable  operation  will  influence  the  accuracy  and 

function. 

Dangers Matters 

1. In some cases, working near intense radiation sources may come about life risk. 

2. Note that, when there is an electronic introducer (for example, pace maker) in human body, 

it may be extremely dangerous in some cases. 

3. The equipment operation shall comply with the local safety regulations. 

4.  The  application  of  equipment  that  can  produce  conduction  or  consume  electromagnetic 

energy shall comply with its operation instructions. 

5. Note that, the secondary radiant matters (for example, reflectors of metal walls) may cause 

amplification effect of the electric field. 

6. Note that, the electric-field strength near the periphery of radiation sources increases to be 

inversely proportional to the third power of the distance. So, when approaching to small 

radiant  sources,  you  will  immediately  feel  large  electric-field  strength  (for  example, 

leakage of wave guide, induction furnace). 

7.  The  tester  for  electric-field  strength  may  underestimate  the  pulse  signal,  especially  the 

radar signal. As a result, it may have obvious measurement errors. 

8.  Testers  for  electric-field  strength  all  have  a  specified  limit  on  frequency  response  range. 

When the spectrum component of the electric field exceeds such frequency range, it may 

generally lead to incorrect estimate and tend to underestimate. Therefore, before using the 

tester for electric-field strength, it shall firstly confirm that all the measured components 

are within the frequency range specified by such tester. 

II. Introduction 

2-1 Key

 

words

 

1.

 

Electromagnetic pollution

 

                    It  is  the  electromagnetic  pollution  generated  by  artificial  electro  field 

E

and 

magnetic  field

H

.  Any  where  with  a  voltage  or  current  there  be  must  such 

Содержание EMF829

Страница 1: ...eflectors of metal walls may cause amplification effect of the electric field 6 Note that the electric field strength near the periphery of radiation sources increases to be inversely proportional to the third power of the distance So when approaching to small radiant sources you will immediately feel large electric field strength for example leakage of wave guide induction furnace 7 The tester fo...

Страница 2: ...iation source the magnetic field intensity mode is suitable to be used 4 Power density S It is the power per unit area on the surface perpendicular to transmitting direction of electromagnetic field The unit of power density is always watt per square meter W m2 Milliwatt per square centimeter mW cm2 is also be used as unit for convenient application 5 Characteristic of electromagnetic field S 1 Th...

Страница 3: ...sed to measure electromagnetic field intense of the transverse electromagnetic wave cell and Absorber rooms The unit and mode are selectable for purpose of using in limits defined in most of regulations The measured value can be displayed in units of electric field intense magnetic field intense and power density The frequency density is very important in high frequency It provides the power absor...

Страница 4: ...ff 15 minutes Operation temperature range 0 C 50 C Operation humidity range 25 75 RH Storage temperature range 10 C 60 C Storage humidity range 0 80 RH Dimension 261cm Length 73cm Width 38cm Height Weight include batteries About 220g Accessory 9V battery carrying case manual 3 2 Electrical specification 1 Unless otherwise stated all specifications hold under the following assumptions device in far...

Страница 5: ...o 35GHz Isotropy deviation about 1 0dB f 50 MHz Overload limit 4 2W m2 40 V m Temperature response 0 to 50 1 5dB VI Operation Description 4 1 Front panel and back panel description 1 Electric sensor 2 Switch key 3 LCD ...

Страница 6: ...And press this key to quit this mode 5 key 1 Press this key to circle among instantaneous maximum instantaneous value average value maximum average value 2 Press this key and hold for 2 seconds to turn into alarm limit setting mode 3 In the CAL setting mode press this key to quit and turn into measurement mode 4 In manual reading mode press this key to quit this mode 5 In the alarm limit setting m...

Страница 7: ...number 1 99 CL Memory clear mode 2 Displayed Automatically turning off is enabled Don t displayed Automatically turning off is disabled 3 MAX Maximum value is displayed AVG Average value is displayed MAX AVG Maximum average value is displayed 4 When the alarm is enabled this symbol means the currently measured value exceed the limitary value 5 ALM Displayed Alarm enabled or in the alarm limitary v...

Страница 8: ...t the operator himself should not stand between inference source and measuring region because human body will insulate the electric field This meter is isotropic and you do not need to do special control on it Just point the sensor part to the target object to measure the electric field It depends on the three axises instead of moving the sensor antenna in the three planes 4 4 Terms to explain 4 4...

Страница 9: ...tense value by the inputted CAL value then display or save the result The range of CAL is from 0 20 to 5 00 CAL is always used to the sensitivity value of the input electric field sensor in order to improve the measurement accuracy of frequency response The CAL provider by electric field sensor is used for this case In most cases the measurement accuracy is enough even if you ignore the frequency ...

Страница 10: ...05V m Alarm limitary value is only suitable to compare with the total value of three axis 4 5 Settings 4 5 1 Set unit Set the unit with key as the figure show 1 Electric field intensity V m 2 Magnetic field intensity mA m 3 Power density mW m2 4 Power density uW cm2 4 5 2 Set display mode After powered on the meter is in instantaneous value mode As the figure show press key to set display mode ...

Страница 11: ...ue 4 5 3 Set alarm limitary value ALM 1 Long press key to get in limitary value setting mode the units and digits on the screen will flash to change the setting values 2 Press or key to increase or decrease the value to what you want 3 Press key to save the value and quit this mode ...

Страница 12: ...e symbol CA appeared to get in CAL setting mode the 4 digits is flashing and can be changed 2 Press or key to increase or decrease to the needed value 3 Press key to save the set value and quit the setting mode 4 5 5 Enable or disable alarm ...

Страница 13: ...attery case cover and take out batteries Turn the right switch to the downside place to switch off the background light Turn the right switch to the upside place to switch on the background light 4 6 Measurement Important illustrate The following influence should be noticed for all the electric field intense meters If you quickly move the sensor the measured value will be bigger than the real elec...

Страница 14: ...adiant source at a distance 4 6 2 Long time exposed measurement Place Place the meter between your work position and the possible radiant source Do the measurement at the part of your body most close to the radiant source Note Only when the instantaneous value changes greatly the average value and maximum average value modes will be used You can fix the meter on a board 4 7 Storage a single value ...

Страница 15: ...t the record number 3 Press key to select the unit 4 Press key to select the axis 5 Press key to quit this mode 4 7 3 Clear memory You can clear the memory as the figure show 1 Long press key the symbol CL and no will appear and the meter is turned into clear mode 2 Press key to select YES ...

Страница 16: ...emory V Operation Preparation 5 1 Mount batteries Open the battery case cover and put in the new batteries 5 2 Change batteries When the voltage is lower than necessary voltage the symbol will appear and it is time to change batteries ...

Отзывы: