PROBLEMS AND SOLUTION
O
Problem
Cause
Solution
The pump does not start
Feed air not sufficient;
Check the air supply line. Increase the
feed hose diameter;
Outlet product line clogged;
Clean. Detach the product outfeed hose
power the pump at minimum pressure
and check if the pump starts without
the outfeed hose;
Clogged product intake line;
Check the hose and the intake filter.
Clean;
The membrane has ruptured;
Replace the membrane;
The drive valve has locked;
press the reset buttons located at the
sides of the valve;
The pump operates at accelerated
speed and does not aspirate the
product
There is no product;
Add the product;
The pump sucks air;
Check the suction pipe;
The “balls” do not close perfectly;
Remove and clean and/or replace the
balls and ball seats;
The pump keeps on stalling
The feed air is insufficient.
Check the air supply line. Increase the
feed hose diameter;
Check that the parts of the air feed cir-
cuit guarantee a sufficient flow rate (the
quick-couplings cause pressure drops).
Always close the compressed air supply and release the pressure in the system before checking or replacing