MAN / AUT
MAN / AU
T
L1
RED
MAN / AUT
MAN / AU
T
L2
L
www.larius.com
20
ED. 04 - 04/2021 - Cod. 150183
LARIUS GHIBLI MIX 2K
Manual controls
Use these fields to switch/open each electro valve individually.
Open the manual controls page by pressing the virtual key on the
touch panel.
START-UP PROCEDURES
The system has two operating modes:
-
MANUAL MODE
-
AUTOMATIC MODE
The operating mode can be selected using the 2-point selector
(
L1
) located on the control panel.
MANUAL MODE
Manual operating mode allows the user to control manually all of
the system’s available functionalities as well as the wash function,
calibration and dispence cycle.
In order to activate the manual operating mode, the user must
turn the selector (
L2
) to the manual position.
The valves are recognisable as follows:
- Ev A: pump A washing valve
- Ev B: pump B washing valve
- Ev solv. 1: Solvent wash valve
The pages are password-protected as only authorized personnel
can access.
The currently set password is
USER = Larius
PASSWORD = Larius
Select the relevant field. The green button will turn red to indicate
the valve opening. Vice-versa to close the valve, simply press the
button, which will turn back to green.
This function is necessary also for performing
a complete wash of the entire system when the
two pumps have to be washed using two different
wash fluids
(i.e. component A requires water to
be used as a wash fluid and the component B
requires the use of a solvent).