WASHING OF THE NEW EQUIPMENT

•  The machine has been tested at the manufacturer’s facilities. 

perform a wash cycle with the paint thinner before suctioning 
any product.

•  place the suction tubes in the solvent containers or else 

pour solvent into the gravity tanks.

•  Make sure that all of the taps are closed.

•  Circulate the solvent within the output pumps and afterwards 

within the entire system.

•  Open the machine’s intake taps, as well as those at the 

flowmeter intake and leave the relative bleeder valves closed.

•  Activate an automatic work cycle and circulate the solvent 

until it comes out of the machine clean.

•  Stop the automatic work cycle and activate a wash cycle. 

This cycle will help the user set all of the wash settings so 
that that machine will be predisposed to perform future wash 
cycles during working phases.

•  During the wash cycle, hold the spray-gun  (

J12

) over a 

container (

J13

) and keep the trigger pulled.

Absolutely avoid to spray solvents indoors.

For disposing of the washing liquid, see the re-
quirements laid down in the Standards in force in 
the country in which the equipment is used and 
act accordingly.  
The Client is solely responsible for any irregular 
action taken before, during, or after disposing of 
washing liquid, or in interpreting and applying the 
current Standards in this regard. 

•  Now the machine is ready.  When water-based paint has 

been used, in addition to washing using the cleaning liquid, 
we recommend washing with soapy water and then clean 
water. 

PREPARING THE PRODUCTS

In order to prepare the products 

(i.e. for dilution)

, refer to the 

supplier’s data sheets.

Make sure the product to be used is compatible 
with the materials employed for manufacturing 
the equipment 

(stainless steel and aluminium)

Because of that, please contact the supplier of 
the product.

WORKING

K

If it is the first time the machine is used, wash. 
The machines are tested and there may be some 
oil residues remaining within.

TURNING THE MACHINE ON

Connect the machine up to the current and then to the air line 
(supply at minimum 6bar). 
Turn the machine on by pressing the switch (

K1

) on th side of the 

control box, setting it to ON.

Содержание LARIUS GHIBLI MIX 2K

Страница 1: ...w w w l a r i u s c o m ED 04 04 2021 Manuale Cod 150183 LARIUS GHIBLI MIX 2K Double components mixing machine EN OPERATING AND MAINTENANCE MANUAL...

Страница 2: ...nical details mentioned in this manual without prior notice This manual is to be considered as an English language translation of the original manual in Italian The manufacturer shall bear no responsi...

Страница 3: ...he results desired quickly and professionally INDEX WARNINGS p 5 WORKING PRINCIPLE p 6 TECNICAL DATA p 7 DESCRIPTION OF THE EQUIPMENT p 8 PNEUMATIC DIAGRAM p 12 PLANT DIAGRAM p 14 TRANSPORT AND UNPACK...

Страница 4: ...I n t e n t i o n a l l y b l a n k p a g e...

Страница 5: ...carry out the decompression procedure explained in this manual and prevent any risk of the equipment starting unexpectedly Report any risk of chemical reaction or explosion if this warning has not be...

Страница 6: ...resistance with respect to mono component paints Sectorsofuse Genericmetalworking WoodworkingandFur nishings Aerospaceindustry Plastics Bicyclesandmotorcycles Automobile components Automobiles Paintin...

Страница 7: ...ly pressure the mixing ratio Temperatures referring to the machine also check the technical data sheets of the products Parts of the pump in contact with the material GHIBLI 40 1 stainless steel A GHI...

Страница 8: ...Pos Description 1 Vega Pump washing solvent 2 GHIBLI product pump A 3 GHIBLI product pump B catalyst 4 Operator Touch panel 5 Electrical panel Pos Description 6 Solvent filter 7 Product delivery 8 Pro...

Страница 9: ...11 12 13 14 www larius com 9 ED 04 04 2021 Cod 150183 LARIUS GHIBLI MIX 2K Pos Description 11 Light indicator 12 Elettrovalve Unit Pos Description 13 Air treating Unit 14 Air supply tap...

Страница 10: ...d 150183 LARIUS GHIBLI MIX 2K Pos Description 15 Air pressure regulator pump B 16 Pump B pressure gauge 17 Product filter B 18 Recirculation drain tap Pos Description 19 Spray gun for washing 20 Spray...

Страница 11: ...2021 Cod 150183 LARIUS GHIBLI MIX 2K Pos Description 22 Atomization air adjustment 23 Fan air adjustment 24 Product filter A 25 Product A suction Pos Description 26 GHIBLI Product pump A 27 Washing pu...

Страница 12: ...arius com 12 ED 04 04 2021 Cod 150183 LARIUS GHIBLI MIX 2K N 1 Product A pump A PAINT GHIBLI 40 1 N 1 Solvent pump DILUENT D GHIBLI 40 1 N 1 Pump used for washing VEGA 5 1 Washing liquid solvent The t...

Страница 13: ...automatic gun A B Solvent delivery W W Flow GHIBLI B Catalyst 30 1 Product GHIBLI 40 1 Product A GHIBLI 40 1 Solvent W VEGA 5 1 Recirculation Non return valve Non return valve Wire encoder Wire encod...

Страница 14: ...S ABOUT THE USE OF SAFETY DEVICES FOR THEIR OWN SAFETY AND ABOUTTHEGENERALRULESFORACCIDENTPREVENTION INCOMPLIANCEWITHINTERNATIONALREGULATIONSAND WITH THE LAWS OF THE COUNTRY WHERE THE PLANT IS USED TH...

Страница 15: ...t be earthed Avoid approaching too much to the pump piston rodwhenthepumpisworkingorunderpressure A sudden movement of the piston rod can cause wounds or finger squashing Neversprayoverflammableproduc...

Страница 16: ...g of the system The machine requires a 220V alternating current power supply Should anyone use an extension cable between the tooling and the socket it must have the same characteristics as the cable...

Страница 17: ...G THE EQUIPMENT TO THE PNEUMATIC LINE Make sure that the air line to be connected to the machine is capable of constantly providing pressure at 7 bar Before opening the air line turn the ball valve J8...

Страница 18: ...solvents indoors For disposing of the washing liquid see the re quirements laid down in the Standards in force in the country in which the equipment is used and act accordingly The Client is solely re...

Страница 19: ...recirculation make sure that the com ponents are flowing in their relative lines up to the mixing block If the equipment is being used for the first time wash it to make surethattherearenooilresidues...

Страница 20: ...on and dispence cycle In order to activate the manual operating mode the user must turn the selector L2 to the manual position The valves are recognisable as follows Ev A Pump A washing valve Ev B Pum...

Страница 21: ...tomatic cycle is used for regular working functionality In order to activate automatic mode functionality the operator must turn the selector L3 to the automatic position To disable the automatic oper...

Страница 22: ...the program which has been loaded onto the PLC The machine is controlled by a touch screen panel Push buttons are represented graphically and the machine can be adjusted or its functions activated by...

Страница 23: ...US The power status is indicated by a green light located on the system s ON OFF selector LOCKING SELECTOR In order to prevent unauthorised personnel from modifying the machine s settings a locking sa...

Страница 24: ...edure shown in the ALARMS screen in the PANEL FUNCTION DESCRIPTION Set the MAN AUT selector to Manual Switch off the electrical panel MAIN SWITCH M15 EMERGENCYBUTTON M16 Ifpressed immediatelydisables...

Страница 25: ...ing expressed in minutes The machine generates a PotLifealarmwhenthistimeexpires Theoperator must renew the product or wash the mixed part If the product is refilled the value shown on the control pag...

Страница 26: ...lueof1 ONE litre in the field Desired amount of product A Click twice on the Enable component A key the message ON will appear Make sure that the component A circuit has been loaded and is pressurised...

Страница 27: ...ed amount of product Note If three way tapping valves are present on the machine for tapping before starting the tapping cycle Makesurethatthecounter pressurenozzlesonthe outletofthesevalvesarecleanan...

Страница 28: ...AUT selector set to MAN The robot places the gun with the nozzle down Withthegunopen thewashingcyclestartsandends with the washing stop signal Allthesetwashingtimesdecreaseaslongastheflow meter signal...

Страница 29: ...hecks of the amount of paint and catalyser used CONSUMPTION Consumption A Display of litres relative to circuit A counted with cycle in Automatic or in Tapping Consumption B Display of litres relative...

Страница 30: ...Dosing valve B closed impulse counting is detected leakage index Check dosing valve B the recirculation tap pump leakage 4 Litre counter A alarm Breakage of encoder wire on pump A1 or A2 5 Litre coun...

Страница 31: ...control on SOLV 1 circuit Flux Washing Solv 2 ON ENABLED OFF DISABLED Enabling of flow meter control on SOLV 2 circuit PressureswitchA Enablingtheminimumproduct pressure control on circuit A EV Air W...

Страница 32: ...t on the next page Check enable Control enabled the control is enabled by moving the cursor to the right and the message ON appears Procedure for storing values set the control pause control i e 5 sec...

Страница 33: ...than the previously stored speed The alarm is activated when the mixing machine is configured with an external counting system linear encoder PressureA Bspeedalarmdelay Delaytimeafter whichthemachine...

Страница 34: ...1 Page relative to the machine with washing with Solvent 1 only Air and Solvent 2 have been disabled from the ADVANCED CONTROL SETUP page Thispageispasswordprotectedasonlyauthorised personnel can acc...

Страница 35: ...ane The drive valve has locked Press the reset buttons located at the sides of the valve The pump operates at accelerated speed and does not aspirate the product There is no product Add the product Th...

Страница 36: ...I n t e n t i o n a l l y b l a n k p a g e...

Страница 37: ...ocation Date complies with the directives EC Directive 2006 42 Machinery Directive EU Directive 2014 30 Electromagnetic Compatibility EMC EU Directive 2014 35 Low Voltage LVD furthermore to the harmon...

Страница 38: ...LARIUS srl Via Antonio Stoppani 21 23801 Calolziocorte LC ITALY TEL 39 0341 621152 Fax 39 0341 621243 larius larius com www larius com...