20
- 20 -
ES
EN
FILTER CLEANING
Caution!
Make sure the
splash shield is installed
correctly before use of
the microwave oven!
The front filter serves as the air inlet; the filter
should be cleaned on time to keep the chamber
clean.
1. Turn counterclockwise to unscrew and take
down the filter; and wash it with warm soap
water;
2. Install the filter screen Tighten clockwise the
screws to fix the filter;
3. Make sure the filter is installed before use of the
microwave oven;
4. The factory setting has the function to remind
the user of washing the filter every 30 days.
(6) Splash shield cleaning
1. Detaching: Hold the two buckle positions in front
of the splash shield with your hands (as shown
by the arrows). Exert your strength following the
direction of the arrows and pull downwards after
you have pulled out the buckles:
2. Wash the splash shield:
3. Installation: Pick up the splash shield and obli-
quely put it into the chamber in the way that
insert the first pin at the rear into the positioning
hole on the rear plate of chamber, then push the
other side to insert all positioning pins into their
positioning holes.
INSTALLATION (SUPPLEMENT)
1. The switching operation of this microwave oven
can cause voltage fluctuations on the supply
line. The operation of this oven under unfavora-
ble voltage supply conditions can have adverse
effects. This device is intended for the connection
to a power supply system with a maximum per-
missible system impedance Zmax of
0.3 Ohms
at the interface point of the user’s supply. The
user has to ensure that this device is connected
only to a power supply system which fulfills the
requirement above. If necessary, the user can ask
the public power supply company for the system
impedance at the interface point.
2. If there is no equipotential bonding conductor in
the electric supply, an external equipotential bon-
ding conductor must be installed at the rear of the
appliance (see symbol).
This terminal shall be in effective electrical con-
tact with all fixed exposed metal parts and shall
allow the connection of a conductor having a
nominal cross-sectional area up to 10 mm².
Symbol for the external connection of
equipotential bonding conductors
Filter
Filter screws
Содержание MO-1817
Страница 62: ......
Страница 63: ......
Страница 64: ...UNE EN ISO 9001 SAMMIC S L Basarte 1 20720 AZKOITIA www sammic com 01 20 0 ER 0437 1 96 ...