background image

 

 Indice de révision : G

9

6102

To have access to the calibrating menu, press keys 4 

 and 5 

 at the same time until the following

screen appears:

The calibration menu permits access for adjustment
of the 

 

GNM

 

 parameters. Access to the menu is done

by means of a 4-number code. The "FATORY" code
is «1111». Enter code by pressing 2 

 and 3 

 and

validating key 4. 

3.2.2.1.  Code entry
Scroll the first figure upwards or downwards with keys 2 

 and 3 

.

Select with key 4 

, then go to the next figure etc. In case of an error, press key 5 

). Validate code

with key 4 

.

After having correctly entered and validated the code, one will read for example:

3.2.2.2.  

 

Di/Dt

 

 Soft Parameters 

 

MP3

 

 

P3

 

 

SP3

 

 

RP3

 

The 

 

Di/Dt

 

 detects sharp changes in current and the sensitivity can be adjusted. The 

 

GNM 100

 

 is built

with two 

 

Di/Dt 

 

control systems. The first 

 

Di/Dt

 

 control is detected by the analog portion of the circuit

board and can not be disabled or adjusted. Its reference is called “Hard 

 

Di/Dt

 

” and is set at a value of

50mA/s. The second 

 

Di/Dt

 

 control is referred to as the Di/Dt soft and can be adjusted to the user’s spe-

cific application.

 

MP3

 

 

Di/Dt

 

 Soft Function

This is a switch that activates the 

 

Di/Dt

 

 soft programming circuitry.

 

P3

 

 

Di/Dt

 

 Soft Threshold Value

This value is the maximum change in current per time value the 

 

Di/Dt

 

 soft programming will allow before

giving an error. This value is expressed in milli amperes per second (mA/s) and can be adjusted in the
following range.

 

SP3

 

 

Di/Dt

 

 Soft Minimum Return Voltage Threshold

This value is minimum voltage return value that must be obtained before the 

 

Di/Dt

 

 soft programmed cir-

cuitry is enabled. This value is expressed in kilovolts (

 

kV

 

) and can be adjusted in the following range.

7

means that the module is in the calibration 
menu

8

T = trigger typeint = internal - ext. = external

9

V = voltage set pointint = local - ext. = dis-
tance

 

MP3

 

 = 1

 

Di/Dt

 

 soft programming is enabled

 

MP3

 

 = 0

 

Di/Dt

 

 soft programming is disabled

 

P3

 

Minimum adjustment

2 mA/s

 

P3

 

 

Maximum adjustment

24 mA/s

 

SP3

 

Minimum adjustment

0 kV

 

SP3

 

 

Maximum adjustment

10 kV

Содержание GNM 100-A

Страница 1: ...8 Merriman Road Livonia Michigan 48 150 Tel 734 261 5970 Fax 734 261 5971 www sames com GNM 100 A Automatic mode of operation This product is protected by French patents N 2724787 et 2724786 which hav...

Страница 2: ...logies is registered as a Training Center approved by the Ministry of Employment Trainings with the aim of getting the necessary know how to use and for the main tenance of your equipment can be organ...

Страница 3: ...lt screens 13 3 3 2 V limit trip I limit trip 14 3 3 3 Coherence trip 14 3 3 4 Fault tempeture 14 3 3 5 Fault CC 14 3 3 6 Fault reg freq 14 3 3 7 Fault supply 14 3 3 8 Starting up of the HV after a mi...

Страница 4: ...iding of cable with a gauge up or equal to 6 mm2 WARNING Customer is responsible the checking which local fire safety standards apply for his operation For a use in cabinet the room temperature must b...

Страница 5: ...e Number E4PTFS343 B PLC Cable 22 Gauge Minimum 0 34mm2 shielded 19 Pin Connector 30 Meters Maximum Length 100 feet Female Plug Reference Number E4PTFS406 C Atomizer Cable Cable no specifications 7 Pi...

Страница 6: ...ecognizes the high voltage unit the unit remains in the automatic operating mode If the high voltage unit is disconnected or the controller is unable to recognize the high voltage unit the controller...

Страница 7: ...Key 4 permits one to go to the next screen 3 2 1 2 Adjusting Current Set Point Current adjustment set point is adjusted by keys 2 and 3 Key 4 permits one to go to the next screen 3 2 1 3 Parameter P5...

Страница 8: ...e list again press key 5 WARNING An interruption in the power supply to the controller erase the list of faults 3 2 1 5 Display of Effective Voltage and Current when Trigger is Activated When the gene...

Страница 9: ...reference is called Hard Di Dt and is set at a value of 50mA s The second Di Dt control is referred to as the Di Dt soft and can be adjusted to the user s spe cific application MP3 Di Dt Soft Function...

Страница 10: ...t voltage P4 s adjustment is linear and in increments of 0 7 milliseconds from 0 to 6 3 milliseconds The response is linear 3 2 2 4 Parameter P6 Voltage Set Point Internal External This parameter is a...

Страница 11: ...in use by Il for limitation and Io for fault management Il and Io are high voltage unit dependent and can be adjusted below their maximum values in the user menu SP19 Minimum Current Return Threshold...

Страница 12: ...ment 1 to 24 mA s SP3 Di Dt inhibition limit 0 10 kV RP3 Di Dt ramp 0 1 1 P4 Set point ramp 0 to 9 P6 Internal external set point 0 1 0 P8 HV enabled upon start up 0 1 0 P9 Fault accepted by external...

Страница 13: ...tion for internal trigger see 3 2 2 4 page 10 3 3 1 Fault screens Major faults Minor faults Fault tempeture Excessive case temperature see 3 3 4 page 14 Fault UP high voltage unit not recognized Fault...

Страница 14: ...sensor which creates a fault if the internal temperature exceeds roughly 70 C 158 F 3 3 5 Fault CC A low voltage short circuit causes a fault 3 3 6 Fault reg freq The GNM is equipped with an automati...

Страница 15: ...rs WARNING see RT Nr 6169 for use with a high voltage unit UHT 153 4 2 1 GNM 100 A module 4 3 Connecting plug 12 pins A Connection to the high voltage unit A Connecting plug 12 pins B Connecting plug...

Страница 16: ...e used for low currents Example of a PLC cabling Cabling for HV ON signalling light N of pins Signal 1 earth 2 phase 1 output protected 3 phase 2 output protected 4 common to trigger image relay 5 tri...

Страница 17: ...ustment point of 16 mA and read the HV value on the GNM screen A simple calculation permits one to fine the corresponding point N of pins Signal 1 Earth 2 Not connected 3 Not connected 4 Input 4 20 mA...

Страница 18: ...ntrol of the Vm output The Vm scale is 0 5 V for 0 100 kV The minimum impedance of the measure equipment has to be 50 k 4 5 2 2 Control of the Im output The Im scale is 0 5 V for 0 500 A The minimum i...

Страница 19: ...follows 4 5 4 Using information relative to the faults The closed contact of the OK board relay signals that the board is under voltage and that there is no fault WARNING This relay is for passing lo...

Страница 20: ...Indice de r vision G 20 6102 Liaison wiring with an PLC Wiring of a HV fault signalling lamp 1 Inside GNM 2 PLC input 14 to 16 GNM case 1 Inside GNM 2 220 VAC oR 110 VAC 3 Fault 14 to 16 GNM case...

Страница 21: ...h key 4 the param eters of this new high voltage unit are automatically selected and all old adjust ments are lost User must confirm new type of high voltage unit 5 Initial menu high voltage unit mode...

Страница 22: ...i Dt soft programming disabled 14 Adjustment of parameter P3 15 Adjustment of parameter SP3 16 Adjustment of parameter RP3 17 Adjustment of parameter P4 18 Adjustment of parameter P6 19 Adjustment of...

Страница 23: ...P19 1 Current management by Fault MP19 0 Current management by Limitation 23 Adjustment of parameter SP19 24 Adjustment of parameter TP19 25 Adjustment of parameter RP19 26 Modify the calibrating menu...

Страница 24: ...2 GNM powered display and green LED on 3 No 4 Power on GNM 5 Yes 6 Turn the GNM off for a minute then on again 7 GNM power on display and green LED on 8 Replace the GNM 9 If an over voltage occurs the...

Страница 25: ...Problem with low voltage cable 3 Yes 4 Replace the low voltage cable 5 No 6 Check the connector s low voltage termi nals 7 Problem with the connector terminals 8 Repair the low voltage terminals 9 Rep...

Страница 26: ...ow voltage cable 3 Yes 4 Defective low voltage cable 5 No 6 Check the connector low voltage termi nals 7 Defective connector terminal 8 Repair replace the low voltage termi nals 9 Replace GNM 10 Has t...

Страница 27: ...orked correctly but current consumption has increased 4 Yes 5 Adjust Il at maximum value 6 Maintenance necessary for the HV sys tem the paint hose becomes conductive air arrival circuit 7 Remove the H...

Страница 28: ...y 7 Check HV cable connections if this is the case length HV contact sufficient quantity of dielectric grease black part of cable earthed 8 Problem solved 9 Adjust parameter P3 10 Apply dielectric gre...

Страница 29: ...e 4 No 5 Carry out same controls for excess of I or Di Dt 6 Yes 7 Check low voltage cable 8 Problem with low voltage cable 9 Replace repair the low voltage cable 10 Check the low voltage connections 1...

Страница 30: ...Description Qty Sold in units of 858224 GNM 100 A metal case 110 220V 1 1 Ref Part number Description Qty Sold in units of 1 E4PTFS316 Male plug 7 contacts 1 1 2 E4PTFS343 Male plug 12 contacts 1 1 3...

Отзывы: