SAMES KREMLIN
- 4 -
N° : 578.093.120-UK-1708
INSTALLATION DIAGRAM
A
Explosive area : Area 1 (Z1) or area 2 (Z2) :
spraybooth
3c
Whip hose
B
Non-explosive area
4
Conductive
air hose
1
Airmix
pump
5
Air regulator (
spraying air)
2
Airmix
gun, model Xcite
™
Light
6
Air regulator (
fluid pressure)
3a
Airmix
fluid hose
7
Airmix
fluid filter
3b
In line filter
The 1 m / 39.37" distance indicated in these diagrams is given for information purposes
only and hold harmless to SAMES KREMLIN. The user is responsible for the extraction
and conditioning of the painting area where the equipment is
used, for working
conditions conditions (refer to EN 60079-10 standard). The 1 m / 39.37" distance may be
modified if trials carried out by the user deem this necessary.
NB: Choose the appropriate pump to ensure that the working pressure supplied is suitable for the
selected gun.
Please use a conductive air hose (minimum internal diameter : 6.5mm / 0.24 inch), for connecting the
gun to the air regulator (capable of supplying at least 3 bar / 44 psi.).
Please ensure when fitting the
high pressure
paint hose, between the gun and the pump that the
fittings are firmly tightened.
NB : In some particular cases, if the air hose (4) is a non-conductive hose, the fluid hose
(3) must be conductive.
One of the 2 hoses (air or fluid) for the gun must be conductive.