582156110-EN-indC-Pump-20F50 pH.docx
20/11/2020
11
Security devices
Attention
Guards (motor cover, coupling guard, housings, …)
are set up for safe use of the equipment.
The manufacturer cannot be held responsible for any
bodily injury as well as failures and / or damage to the
equipment resulting from the destruction, hiding or
total or partial removal of the guards.
Never exceed the maximum working pressures of the
equipment components.
Pressure hazards
Safety requires that a
pressure relief air
shut-off valve must be installed
in the pump motor supply system to allow trapped air to escape
when the supply is shut off.
Without this precaution, residual air from the motor may cause the
motor pump to operate and cause a serious accident.
Also, a
fluid drain valve
must be installed in the fluid system so that the
fluid can be drained (after shutting off motor air and decompressing
it) before any intervention on the equipment. These valves must
remain closed for air and open for the product during the
intervention.
Содержание 20F50
Страница 27: ...582156110 EN indC Pump 20F50 pH docx 20 11 2020 27 Air supply assembly...
Страница 28: ...20 11 2020 582156110 EN indC Pump 20F50 pH docx 28 Fluid filter 3 8 model 250 bar 3625 75 psi...
Страница 32: ...20 11 2020 582156110 EN indC Pump 20F50 pH docx 32...
Страница 58: ...20 11 2020 582156110 EN indC Pump 20F50 pH docx 58 Remove the fluid tube 47 and the nut...
Страница 59: ...582156110 EN indC Pump 20F50 pH docx 20 11 2020 59 Remove and replace the seals 36 44 and 45 36 44 45...
Страница 76: ...20 11 2020 582156110 EN indC Pump 20F50 pH docx 76 Remove the fluid tube 47 and the nut...
Страница 77: ...582156110 EN indC Pump 20F50 pH docx 20 11 2020 77 Remove and replace the seals 36 44 and 45 36 44 45...
Страница 97: ...582156110 EN indC Pump 20F50 pH docx 20 11 2020 97 Remove the fluid tube 47 and the nut...
Страница 98: ...20 11 2020 582156110 EN indC Pump 20F50 pH docx 98 Remove and replace the seals 36 44 and 45 36 44 45...
Страница 105: ...582156110 EN indC Pump 20F50 pH docx 20 11 2020 105 Remove the fluid tube 47 and the nut...
Страница 106: ...20 11 2020 582156110 EN indC Pump 20F50 pH docx 106 Remove and replace the seals 36 44 and 45 36 44 45...
Страница 107: ...582156110 EN indC Pump 20F50 pH docx 20 11 2020 107 Unscrew the cylinder 27 with a 50 mm wrench Tools needed 50 27...
Страница 115: ...582156110 EN indC Pump 20F50 pH docx 20 11 2020 115 Remove the fluid tube 47 and the nut...
Страница 116: ...20 11 2020 582156110 EN indC Pump 20F50 pH docx 116 Remove and replace the seals 36 44 and 45 36 44 45...
Страница 117: ...582156110 EN indC Pump 20F50 pH docx 20 11 2020 117 Unscrew the cylinder 27 with a 50 mm wrench Tools needed 50 27...
Страница 134: ...20 11 2020 582156110 EN indC Pump 20F50 pH docx 134 Remove the cylinder seal 41 with a flat screwdriver Tools needed 41...
Страница 147: ...582156110 EN indC Pump 20F50 pH docx 20 11 2020 147 Place the muffler 27 Place the cover 32 27 32...
Страница 148: ...20 11 2020 582156110 EN indC Pump 20F50 pH docx 148 Tighten the 2 screws 33 with a 5 mm Allen wrench Tools needed 33 5...
Страница 156: ...20 11 2020 582156110 EN indC Pump 20F50 pH docx 156 14 2 Motor model 500 4 stroke 100 Motor part number 146 260 000...
Страница 162: ...20 11 2020 582156110 EN indC Pump 20F50 pH docx 162 14 4 Fluid section model F50 pH Fluid section part number NS...
Страница 168: ...20 11 2020 582156110 EN indC Pump 20F50 pH docx 168 Package of seals 144 951 090...
Страница 170: ...20 11 2020 582156110 EN indC Pump 20F50 pH docx 170 14 5 Air supply assembly Air supply assembly part number 151 796 130...
Страница 173: ...582156110 EN indC Pump 20F50 pH docx 20 11 2020 173...