SAMES KREMLIN
- 1 -
N° 578.209.110-UK-1907
CAUTION :
Before any action on the pump, the T lubricant should be removed, shut off the
compressed air supply and depressurize the system.
The pump is manufactured under the ATEX agreement and can not be modified.
SAMES KREMLIN will not be held responsible for any failure to comply with that instruction.
FLUID MOTOR OR AIR MOTOR REPLACEMENT (REFER TO DOC. 573.462.050 & 573.463.050)
Guards (air motor cover, coupling shields, housings …) have been designed for
safe use of the equipment.
The manufacturer will not be held responsible for bodily injury or failure and / or
damage to property due to removal or partial removal of the guards
To work on the pump, it requires to :
- Disassemble all the accessories of the pump (rod, filter), if necessary.
- The T lubricant should be removed from the upper part (A).
- Put aside the pump, if necessary (the pump is fitted with an hoisting ring).
The pump fluid section is made up of 2 sub-
assemblies :
- the upper part (bellows suction
sub-assembly : A)
- the lower part
(fluid sub-assembly: B)
The most frequently maintenance
concerns this part.