Electrical connection
Attention!
The electrical connection of the equipment may only be carried out by
qualified and skilled personnel!
Attention!
It is absolutely necessary to ground the RoughCam
®
series’ housing
via the PA connection.
The delivered RoughCam
®
IPM2036 is equipped with an electrical connection cable of
the type SKD01-T/ASKD02-T (models without cooling) or type SKD05-HT (models with
cool.Jacket). The maximum transmission range from the camera to the next active
network interface is 100 meters (without cool.Jacket) or 60 meters (models L.HH) and
can be individually specified by the client. The user is NOT authorised to do electrical
connection procedures inside the enclosure.
5.1
Potential equalization
Figure 5-1 RoughCam IPM2036 Potential equalization
Potential equalization/grounding of the camera housing is absolutely necessary, in order
to avoid static charges and thus the formation of sparks. For this purpose, a screw termi-
nal is provided at the rear side, at the bottom (right) (see Figure 5-1). The cross-section
of the potential equalization should comply with the National Ground Rules (at least
4mm
2
).
Wiring table:
Potential
Colour (IEC 60757)
Cross-
section
Comment
PA
GN/YE
4 mm
2
(rigid)
Terminal: Slotted screw M4x0.7 (DIN 84) with
washer Ø9mm (DIN 125A),
Keep 3 Nm tightening torque!
Table 5-1 Potential equalization