background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Ex

Cam

®

 

XF P1367

 

 
 
 
 
 

User Manual 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Содержание ExCam XF P1367

Страница 1: ...ExCam XF P1367 User Manual ...

Страница 2: ...3 1 Example direct routing from the ExTB 3 to the safe area 14 5 3 2 Example Routing via ExConnection Rail optional accessories 15 5 3 3 Appropriate cables cable entries 16 5 3 4 Cable kits plug and play connection packages 17 5 3 5 Fusing 18 5 3 6 Tests prior to switching on the voltage 19 6 Working in the camera housing 19 6 1 Work preparation 19 6 2 Opening the pressure resistant housing 20 6 3...

Страница 3: ...ug play connection package 17 Tab 5 4 Available cable kits 18 Tab 5 5 Recommendation for fusing 18 Fig 6 1 Removing the weather protection roof 1 2 this illustration is an example 20 Fig 6 2 Removing the weather protection roof 2 2 similar illustration 21 Fig 6 3 Opening the ExCam XF P1367 similar illustration 21 Fig 6 4 Mounting adapter with built in components 23 Fig 7 1 User Interface for setti...

Страница 4: ...onary device installation but also mobile applications hand held use etc To see other approvals please visit our website at www samcon eu When designing the ExCam XF P1367 we focused very much on safety mechanical precision and a high quality stainless steel 2 Technical data 2 1 Explosion protection Identification marks acc to Directive 2014 34 EU Model key T08 VA2 3 K3 BOR2 LL H 005 N P II 2G zon...

Страница 5: ... consumption 5 0 W 2 3 Connection cable Ex d Ex e SKDP03 T Description Data transfer and power supply of the camera module compliant with DIN EN 60079 14 Jacket colour green GN similar to RAL3001 Outside diameter 12 4 0 3 mm Bending radius 8 x Da when installed and 4 x Da after installation Data line 4 x 2 x AWG23 1 CAT 6a Performance elements 3G1 5 BK BU GN YE Properties PUR halogen free flame re...

Страница 6: ...ted in the Ex installation instructions of the T08 ExCam series Quick link https www samcon eu fileadmin documents en 22 Ex Network Cameras ExCam Series T08 EX Installation Manual 2018 pdf It is absolutely mandatory to observe the national safety regulations and regula tions for prevention of accidents as well as the safety instructions given below in this User Manual Attention Cameras of the type...

Страница 7: ...ant national regulations as well as the generally accepted rules of technology shall prevail Before mounting the camera thor oughly check it for any transport damage especially on the housing and cable Installa tion electrical connection and the first start must only be carried out by qualified special ists Work preparation Attention Prepare your work carefully and in accordance with the relevant ...

Страница 8: ...l and local regulations for mounting heavy loads If in doubt take appropriate security measures Drawings for drill hole patterns and further information can be viewed on our product page Quick link https www samcon eu en products network excam xf p1367 Option mounting accessories Wall bracket WMB WALL MOUNT EXCAM XF 01569 001 Wall bracket for devices of T08 VA3 series Suitable for hanging the came...

Страница 9: ... P1367 is equipped with an electrical connection cable of the type SKDP03 T The maximum transmission range from the camera to the next active network interface is 100 meters and can be individually specified by the client The user is NOT authorised to do electrical connection procedures inside the pressure resistant enclosure 5 1 Potential equalization The potential equalization grounding of the c...

Страница 10: ...To ensure the power supply of ExCam XF P1367 Powered Device PD it is necessary to make sure that the power over Ethernet provider Power Sourcing Equipment PSE on the connection side for example PoE Midspan PoE injector switch etc fulfils the speci fication IEEE 802 3af and 802 3at type 1 Class 3 classification current 26 30 mA 48VDC max feed in power power source equipment 15 4 W maximum offtake p...

Страница 11: ...5mm2 stranded wire 24 V DC 40 W of continuous power Fine wire fuse L 4000 mA T slow blow high inrush load L 2 BU 1 5mm2 stranded wire 0 V DC GND Tab 5 2 Wire assignment in power cables 5 2 3 Connection to a terminal box alternatively If you have to connect the camera to a terminal box please remove the plug properly according to good professional practice In this case it is imperative to ensure a ...

Страница 12: ...25 mm2 Solid conductor Rx WH GN 3 0 25 mm2 Solid conductor Rx GN 4 0 25 mm2 Solid conductor PoE 48 VDC WH BU 5 0 25 mm2 Solid conductor PoE 48 VDC BU 6 0 25 mm2 Solid conductor PoE GND WH BN 7 0 25 mm2 Solid conductor PoE GND BN 8 0 25 mm2 Solid conductor GND SHD YE GN PE 2 5 mm2 Flex L BK 9 1 5 mm2 L 24VDC L BU 10 1 5 mm2 L 24VDC PE YE GN PE 1 5 mm2 PE Tab 5 3 Wire assignment of terminal box ExTB...

Страница 13: ...Doc ID 190314 PT08BA ES ExCam XF P1367_EN_rev 00 docx Page 13 of 32 Fig 5 5 Sample circuit of terminal box ExTB 3 Fig 5 6 Photo of the occupied terminal box ExTB 3 ...

Страница 14: ...pproximately 10mm close to the termi nals in order to ensure the interference immunity Attention Use only terminals approved by SAMCON Attention Finally check your network installation by per Class D Link Test 5 3 Example external connection and fusing via the terminal box There are several options of routing the ExTB 3 terminal box in a safe area 5 3 1 Example direct routing from the ExTB 3 to th...

Страница 15: ...C 60079 0 1 7 14 Attention The supply line must have a sufficient cross section The cable pro tection must comply with national and international regulations 5 3 2 Example Routing via ExConnection Rail optional accessories Fig 5 8 ExTB 3 ExConnection Rail In the case of routing the ExTB 3 into an ExConnection Rail larger installation distances can be covered Please note In hazardous areas the ExCo...

Страница 16: ... cable pro tection must comply with national and international regulations To see non binding configuration and planning guidelines please visit our website Particularly for installations requiring a suitable barrier gland make sure that you handle them correctly and observe the rules and notes given in the respective mounting and as sembly instructions We show the basic procedures in the followin...

Страница 17: ...001 This cable set includes 10 meters SKDP03 T system cable digital 1 barrier gland Ex d 5 ml Loctite 243 screw locking 1 x CAT6 RJ45 industrial plug 1 set of documents ASKDP03 T CABLE EXCAM 10M 01543 001 This cable set includes 10 meters ASKDP03 T system cable digital 1 bolted connection Ex d 1 bolted connection Ex e 5 ml Loctite 243 screw locking 1 x CAT6 RJ45 industrial plug 1 set of documents ...

Страница 18: ...5M 01542 001 This cable set includes 95 meters ASKDP03 T system cable digital 1 bolted connection Ex d 1 bolted connection Ex e 5 ml Loctite 243 screw locking 1 x CAT6 RJ45 industrial plug 1 set of documents Tab 5 4 Available cable kits 5 3 5 Fusing PoE power supply requires no fuses The power supply fusing depends on the cable cross section and length Attention Recommendation for fusing relates t...

Страница 19: ...r may open the housing only if it is absolutely necessary Only exchanging the SD memory card or a hardware reset are reasons for this Open the pressure resistant housing extremely carefully After having finished the work securely re close it and ensure that the explosion protection is restored To do this you need to proceed step by step as described in the instructions below 6 1 Work preparation A...

Страница 20: ... camera housing Opening the housing requires disassembly and working in a safe i e non explosive area Attention Pay attention not to damage the thread surface of the flame proof gap Attention Pay attention not to damage the housing seals Keep them clean If the ExCam XF P1367 is equipped with a weather protection roof optional accessory remove the roof before you start working To do so untighten th...

Страница 21: ...re is LOCTITE 243 chemical basis is dimethacrylate ester applied to prevent the bolt ed connection from unintentional loosening because of impacts and vibrations and to seal them tightly It is not permitted for the customer to open the front side sight glass flange There is no need of such an action Carefully pull out the cable and supply flange to the rear as straight as possible Be cause of nega...

Страница 22: ...n built components Caution Do not touch the cylindrical fit surface with your skin or clothes On the surface there is oil lubricating paste to protect the surface against fretting corrosion and mechani cal stresses When you open the housing heed that you do not damage the GYLON flat seal blue RAL5012 and do not make it dirty The flat gasket is loosely attached to the cable and power supply flange ...

Страница 23: ...twork If the memory card has to be replaced by the user it should be as far as possible empty and pre formatted with an ext4 or vFAT file system When touching electrical components observe potential equalization grounding of the body carry electrostatic discharge clothes a PE wristband etc The illustration is only an example the lens is changed 1 MicroSD card slot 2 Status LED 3 Built in microphon...

Страница 24: ... be reset to the factory settings axis If there is a DHCP server in the network the IP address will be the following 192 168 0 90 subnet masking 255 255 255 0 5 IP address and password can be redefined If the hardware reset is not satisfacto ry or the network camera shows serious conflicts or does not work as usually er rors in the browser visualisation frozen images control commands no longer pro...

Страница 25: ...t with lubricant suitable for this specific application e g Mo lykote P 40 gel for standard applications or special grease OKS 403 in the event of heavy seawater influence The screwed connections of flange and body components must always be tightened crosswise at a torque of 3 Nm Do not tighten the screws too strongly It can cause rup ture of the cylinder head or over stretching the threads and th...

Страница 26: ...ettings focus sharpness digital zoom etc to be done via the web interface do not al low the user to achieve the desired results P 1367 Lens type Varifocal IR corrected CS mount mega pixel Iris control ICS iris F1 2 2 9 mm aspherical technology No Focal length 2 8 8 5 mm Image angle horizontal 98 wide 36 tele Control characteristic iris automatic the camera module contains an analogue circuit MOD m...

Страница 27: ...it counter clockwise By moving the two regulators adjust the zoom strength and image sharpness Check the image quality in the window below 5 Re tighten the zoom and sharpness regulators 6 The click on the button Fine tune focus automatically in the configuration menu and wait until the automatic optimization is finished 7 To re enable the iris click Enable iris If the button is disabled this means...

Страница 28: ...st of today s networks a DHCP server is integrated This server automatically assigns an IP address If there is no DHCP server available in the network the IP default address of ExCam XF P1367 is 192 168 0 90 subnet masking 255 255 255 0 With the AXIS IP Utility it is possible to determine the IP address under Windows the included USB stick contains this application If it is not possible to assign ...

Страница 29: ...l devices in po tentially explosive atmospheres must be adhered to The required maintenance intervals are specific to the individual devices The operating company has to determine these intervals depending on the application parameters The maintenance tasks especially include examination of parts on which the ignition protec tion depends e g proper condition of the casing seals and cable entry poi...

Страница 30: ...rdance with nationally applied regulations by SAMCON Prozessleittechnik GmbH or by an electrical technician authorized by SAMCON Prozessleittechnik GmbH Rebuilding of or alterations to the devices are not permitted 11 Disposal Recycling When disposing of the device nationally applicable regulations must be observed This Document is subject to alterations and additions 12 Drawings 3D models All dra...

Страница 31: ...sh additional technical information please contact us at support samcon eu 13 Certificates and further documentation Certificates and further documentation are available in the download area at the product website Quick link https www samcon eu en products network excam xf p1367 ...

Страница 32: ...Schillerstrasse 17 35102 Lohra Altenvers Germany www samcon eu info samcon eu Phone 49 6426 9231 0 fax 31 ...