Sirius 800 Series User Manual
Control/Fan Interface Module Compatibility
Control/Fan Interface Module 15.1
Iss 5 Rev 7
Page 293
© 2017 SAM
Red
Remote
Error
(not 2453/
2455/2457)
Error with messages from remote
Nucleus control module
Sirius 830
- not fitted
Sirius 840/850
- (no
expansion):
Off
- Expansion not used.
Sirius 850
(expanded to
second frame):
Off
- normal state,
Flashing
- the command
message from the remote
router controller is corrupt
or hasn’t been received.
This communications error
could be caused by a
hardware failure although
this is unlikely. Check that
the module is inserted
correctly and the four RJ45
connections between the
frames are fitted correctly
(see section 12.2).
If the “Remote Error” LED
is flashing at the same time
as the “Remote Command
OK” LED is flashing it
suggests a mismatch in the
configuration of the
Nucleus controller.
Green
Active
Card is active
On Solid
- working
correctly
Figure 188 Control/Fan Interface Module LEDs
LED Color Function
Detail
Normal Working Status
Table 83
Control/Fan Interface Module LED Indication
Power OK
Local COM OK
Local Com Error
Rem
o
te COM OK (n
ot 245
3/24
55/24
57
)
Rem
o
te COM Err
o
r
(n
o
t 2
453
/2
455
/245
7)
Activ
e
OK