background image

 

-1-

-2-

-3-

1. Overview

The SWITCH 4008GT Lite-Managed Industrial Ethernet Switch 

is designed for harsh environments to withstand vibration, 

shock, free fall, power surges. The switch is easy to set-up and 

supports the critical software features required in factory automa-

tion systems such as multi-axis robots and their peripherals 

(PLC's,  HMI's and legacy devices).  The switch includes 8-port 

10/100/1000Mbps RJ45 downlink ports.

2. Package Checklist

Panel view

4. Grounding the switch

5.1  Wiring Power Input

Grounding and wire routing help limit the effects of noise due to 

electromagnetic interference (EMI). Run the ground connection 

from the ground screw to the grounding surface prior to connect-

ing devices.

!

ATTENTION:  

A corrosion-free mounting rail is advisable. When 

installing, make sure to allow for enough space 

between devices to properly install the cabling. And 

provide ample space for air flow.

3. Mounting and Dismounting to DIN-Rail

!

ATTENTION:  

The Switch is an open type device and shall be DIN-Rail 

mounted or wall mounted (optional) in the cabinet and 

the ambient temperature should not exceed the operat-

ing temperature.

!

ATTENTION:  

This product is intended to be mounted to a well-ground-

ed mounting surface such as a metal panel.

To insert power wire and connect the specified voltage range at 

a maximum of 0.35A DC power to the power terminal block, 

follow the steps below:
1. Use a flat-head screwdriver to loosen the wire-clamp screws

2. Insert the negative/positive DC wires into the PWR-/PWR+  

terminals, respectively

3.  Tighten the wire-clamp screws to prevent the wires from loosen-

!

WARNING:
Safety measures should be taken before connecting 

the power cable. Turn off the power before connecting 

modules or wires. The correct power supply voltage is 

listed on the product label. Check the voltage of your 

power source to make sure that you are using the 

correct voltage. DO NOT use a voltage greater than 

Please read and follow these guidelines: 

•  Use separate paths to route wiring for power and devices. If 

power wiring and device wiring paths must cross make sure 

the wires are perpendicular at the intersection point.

 NOTE: 

Do not run signal or communications wiring and power 

wiring through the same wire conduit. To avoid interference, 

wires  with  different  signal  characteristics  should  be  routed 

separately.

•  You can use the type of signal transmitted through a wire to 

determine which wires should be kept separate. The rule of 

thumb is that wiring that shares similar electrical characteris-

tics can be bundled together

•  You should separate input wiring from output wiring

•  We advise that you label the wiring to all devices in the system

Removing the Switch

Mounting the Switch

Clic k

Mounting the switch

Place the switch on the DIN-Rail from above using the slot, push 

the front of the switch toward the mounting surface until it snaps 

into place with a click sound.

5. Wiring requirements

Dismounting the switch

Press the switch from top and pull out the lower edge of the 

switch and then remove the switch from the DIN-Rail.

what  is  specified  on  the  product  label.  Calculate  the 

maximum possible current in each power wire and 

common wire. Observe all electrical codes dictating 

the maximum current allowable for each wire size. If 

current exceeds the maximum rating, the wiring can 

overheat causing serious damage to your equipment.

Top View

Grounding

Screw

Power Input

Terminal  Block

DIP Switches 

Reset

24~48V

D

C

PWR

+

+

RPS

ALM

OFF

1

2

ON

1 PWR

ALM

RPS

2

PWR

RPS

ALM

PWR RPS ALM

LNK/

ACT

1000

1

3

5

7

2

4

6

8

1000Mbps

(Green)

LNK/ACT

(Green)

Grounding Screw

SWITCH 4008GT 

Quick Installation Guide

• SWITCH 4008GT Switch x 1

!

Caution:  

•  Use copper conductors only

•  Wiring cable temperature should support at 

least 105˚C 

•  Tighten the wire to a torque value 20N

•  The wire gauge for the terminal block should 

range between 0.2 to 2.5 mm

2

You can use “PWR” for Primary Power input and “RPS” for 

Redundant Power Input.  

Top view of Terminal Block is shown in the figure below: 

Terminal Block

Отзывы: