4.
Putting the cabinet into service
Installation
•
Place the cabinet on a firm surface and ensure that it is level.
•
The cabinet cannot tip over and fall due to its heavy weight.
•
Place the cabinet where the door can open 180°.
•
Ensure that the cabinet is in a well-ventilated room. Depending on its duration, a fire may
produce poisonous gasses.
Switching on the cabinet
•
On the outside of the cabinet is an electricity cable approx. 1.5 metres long that is fitted with a
three-pole CEE-form 230V 16A plug as standard. Push the plug directly into a compatible wall
socket. Do not use an extension cable.
•
Ensure that the cabinet cable is connected to an exclusive circuit in accordance with NEN
regulations.
•
Make sure that the fuse switch in the cabinet is up (position 1). The fuse switch is inside the
cabinet on the outside of the lowest technical compartment.
•
Ensure that the maximum power of the cabinet (3600W) is never exceeded.
•
Ensure that the maximum load-bearing capacity of the shelves of approx. 60 kg is never
exceeded.
•
Always keep the cabinet door closed so that any fire is limited to inside the cabinet.
•
Never impede the smoke duct and the ventilation grill by placing anything on top of the
cabinet.
Opening and closing the cabinet door
Opening the cabinet door
•
Turn the handle to the open position.
•
Open the door as far as possible without forcing until it stays open.
Closing the cabinet door
•
Turn the handle to the closed position.
•
If the door remains open, an alarm will sound after two minutes to indicate that the door must
be closed.
•
Closing the door is entirely mechanical and requires very little force from the locking
mechanism. There is therefore very little risk involved and there is little danger of injury.
Содержание L1-8