Salus SS912ZB Скачать руководство пользователя страница 1

Version 3 

 

Installation/Quick Start Guide: Slim Door/Window Sensor (SS912ZB) 

Visit 

www.salusinc.com

 for the User Manual

 

In the Box 

 

 

 

 

Tools Needed 

  Note: 

 

 

 

 

 

 

 

  Additional  equipment  may  be  required 

due to building construction or materials, 
or  other  radio  interference  that  may 
reduce the radio range. 

Sensor with battery 

(1x CR2, 3V Lithium)  

Magnet 

Mounting Kit 

Installation/ 

Quick-start Guide 

 

#1 Phillips Screwdriver 

 

 

 

 

 

 

 

 

 

P

AIRING 

I

NSTRUCTIONS

 

 

Follow your system’s instructions to prepare to add devices to the system. 

 

Remove the face plate from the Sensor and pull the battery tab to start 

the pairing process. 

 

When the Sensor is detected and added to the system, proceed to the 

Sensor installation. 

I

NSTALLATION 

I

NSTRUCTION

 

 

Identify the location for the Sensor and Magnet, orienting the 

flat end

 of 

the Sensor and Magnet 

parallel

 to each other as shown, and the 

Magnet on the right side (side with indicator). 

The preferred location 

for the Sensor is on the door or window casing on the handle side of 

the door or window, with the Magnet on the door or window as close as 

possible to the Sensor. Proper installation may require mounting the 

Sensor and Magnet inverted or rotated from the orientation shown. 

 

Position the Sensor at the desired location and screw into position 

using the screws provided.

 

If screws are not appropriate, use the included 

adhesive pad by first removing the brown backing of the adhesive pad 

and attaching it to the Sensor bottom. Make sure to properly align the 

tamper switch opening. Then remove the white/red paper tape and press 

the Sensor to the desired location. 

(For UL installations, the unit must 

be mounted with screws.)

 

 

Open the Magnet case, position the Magnet at the desired location and 

attach to the door or window with the screws, replacing the Magnet cover 

when done. If screws are not appropriate, use the adhesive pad by first 

removing the brown backing and attaching it to the Magnet bottom. Then 

remove the white/red paper tape and press the Magnet to the desired 

location. 

(For UL installations, the unit must be mounted with screws.) 

Depending on the depth of the door or window in the frame, the included 

spacer may be required to raise the Magnet above the surface of the door or 

window. Use the longer screws to attach the Magnet with the spacer. 

 

Open and close the door to verify that the Sensor is working properly, and 

the Sensor or Magnet does not interfere with the opening and closing of the 

door. 

R

EPLACING THE 

B

ATTERY

 

(Use only Duracell DL-CR2, Rayovac RL-CR2, Energizer EL1CR2, or GP Batteries GPCR2 batteries)

 

 

Slide the Sensor face plate up and lift it from the Sensor body.  

 

Press a finger on the positive end of the battery and lift to remove the battery 

from the Sensor. 

 

Insert a new battery into the Sensor, observing the proper polarity.  

 

Position the Sensor face plate over the Sensor body and slide the face plate onto 

the Body. 

F

ACTORY 

R

ESETTING THE 

S

ENSOR

 

 

Remove the face plate from the Sensor. 

 

Remove the battery. 

 

Press and hold the tamper switch while re-inserting the battery. 

 

Release the tamper switch when the LED lights on the front of the Sensor. The 

Sensor is reset to factory defaults and will respond to pairing requests. 

 

After pairing, replace the face plate on the Sensor. 

LED

 

I

NDICATIONS

 

Solid at power up: 

Initializing, checking for Factory Reset 

3 flashes then pause: 

Searching for network to join 

 

Отзывы: