7 .3
Function
Parameters
Description
Default
Value
d00
Select Units
0
0
SI Metric Units - °C
1
US Customary Units - °F
d01
Heating Control
0
0
Time Proportional & Integral (TPI)
1
ON/OFF – 0 .5°C (1 .0°F) Increments
2
ON/OFF – 1 .0°C (2 .0°F) increments
d02
Temp . Offset
0
-6ºF to +6ºF
(-3 .0ºC to +3 .0ºC )
Room Temperature Offset (1 .0°F/0 .5°C increments)
d03
Outdoor Sensor
0
0
Outdoor Sensor not connected to S1/S2
1
Outdoor Sensor or Ext . (d04) connected (10 kΩ)
3
Not Used
d04
External Sensor
0
0
d03 = 1, Ext . air sensor active, Int . sensor inactive
1
d03 = 1, Ext . floor sensor active, Int . sensor active
d05
Cooling Control
2
1
ON/OFF – 1 .0°F (0 .5°C) increments
2
ON/OFF – 2 .0°F (1 .0°C ) increments
d06
Actuator Type
1
0
NO Normally Open
1
NC Normally Closed
d07
Valve Protection
1
0
ARV10RFM Valve Exercise Disable
1
ARV10RFM Valve Exercise Enable
d08
Frost Setpoint
41ºF (5 .0ºC)
41ºF to 63ºF
(5 .0ºC -to 17ºC )
Minimum room temperature for frost protection and holiday mode
d09
Hour Format
1
0
12 Hour Time Format (eg . 5:00 pm)
1
24 Hour Time Format (eg . 17:00)
d10
Not Applicable
N/A
N/A
This function is not applicable
d11
Daylight Savings
1
0
Daylight Savings Time (DST) Off
1
Daylight Savings Time (DST) On
d12
Max . Heat
Setpoint
95ºF (35ºC)
42ºF to 95ºF
(17 .5ºC to 35 .0ºC)
Maximum setpoint for heating mode
d13
Max . Cool Setpoint
41ºF (5ºC)
41ºF to 104ºF
(5 .0ºC to 40 .0ºC)
Maximum setpoint for cooling mode
d14
Floor Sensor High
Limit (heating)
81°F (27°C)
59ºF to 113ºF
(15 .0ºC to 45 .0ºC)
Disable heat demand when floor temperature is above high limit .
Increment: 1°F (0 .5°C)
d15
Floor Sensor Low
Limit (heating)
50°F (10°C)
43ºF to 104ºF
(6 .0ºC to 40 .0ºC)
Provide heat demand when floor temperature is below low limit .
Increment: 1°F (0 .5°C)
d16
Floor Sensor Low
Limit (cooling)
43°F (6°C)
43ºF to 113ºF
(6 .0ºC to 45 .0ºC)
Disable cooling demand when floor temperature is below low limit .
Increment: 1°F (0 .5°C)
d17
Preset Programs
1
0-1
Select program . Once selected, the selected program will overwrite
the present program .
d18
Heat/Cool Mode
Selection
0
0
Disable Heat/Cool selection
1
Enable Heat/Cool selection
Section 7
Setting Device Parameters
AS20WRF/BRF Thermostat – Functions & Parameters
Содержание SG888ZB
Страница 1: ...Wireless Controls System Guide As of September 6 2018...
Страница 4: ......
Страница 21: ...3 13...