Quick Guide Installation
Model: RT510 / RT510RF / RT510TX / RT510BC / RXRT510
Always isolate the AC Mains supply before installing or working
on any components that require 230 VAC 50Hz supply.
Introduction
The RT510 thermostat will switch your heating system on or off, as needed, in accordance with the temperature set
by you. The RT510 series includes the following products:
• RT510 for wired applications
• RT510RF (R RXRT510) for wireless applications
• RT510TX for wireless application, using 5 x 5 receiver
• RXRT510 for wireless application using 5 x 5 transmitter
• RT510BC for wireless application
Go to www.salus-manuals.com for the full PDF version of the manual.
Product Compliance
EU Directives: 2014/53/EU and 2011/65/EU. Please check www.saluslegal.com for the full information.
Safety Information
Use in accordance with the EU and national regulations. For indoor use only.
Keep your device completely dry. This product must be installed by a competent person and in accordance with all
the EU and national regulations.
Button Functions RT510 and RT510TX
Pairing the RT510TX with the Receiver/Boiler Controller
Installer Mode
Dip Switch Settings
RT510 & RT510RF Quick Guide
RESET
+Hr
SELECT
SET
RESET
+Hr
SELECT
SET
TEST / PAIRING
SELECT
+Hr
SET
TEST / PAIRING
SELECT
+Hr
SET
RT510
RT510TX
COM
NO
L N
Terminal
Description
Receiver Terminals
NO
COM
L
N
Switch Terminal
Common Switch Terminal
Mains Live (230VAC)
Mains Neutral
RT510BC (Boiler Controller)
Wire up the boiler controller and switch it ON. After that please insert the
batteries into the thermostat.
Leave the link wire in the boiler
Remove the link wire in the boiler
N
L
1
2
3
4
N
L
1
2
3
4
5
6
N
L
1
2
3
4
N
L
1
2
3
4
5
6
N
L
1
2
3
4
N
L
1
2
3
4
5
6
N
L
1
2
3
4
N
L
1
2
3
4
5
6
N
L
1
2
3
4
N
L
1
2
3
4
5
6
N
L
1
2
3
4
N
L
1
2
3
4
5
6
N
L
1
2
3
4
N
L
1
2
3
4
5
6
N
L
1
2
3
4
N
L
1
2
3
4
5
6
NL
12
34
NL
12
34
56
NL
12
34
NL
12
34
56
NL
12
34
NL
12
34
56
NL
12
34
NL
12
34
56
NL
12
34
NL
12
34
56
NL
12
34
NL
12
34
56
NL
12
34
NL
12
34
56
NL
12
34
NL
12
34
56
NL
12
34
NL
12
34
56
NL
12
34
NL
12
34
56
NL
12
34
NL
12
34
56
NL
12
34
NL
12
34
56
NL
12
34
NL
12
34
56
NL
12
34
NL
12
34
56
N
L
1
2
3
4
N
L
1
2
3
4
5
6
NL
12
34
NL
12
34
56
NL
12
34
NL
12
34
56
NL
12
34
NL
12
34
56
NL
12
34
NL
12
34
56
NL
12
34
NL
12
34
56
N
L
1
2
3
4
N
L
1
2
3
4
5
6
N
L
1
2
3
4
N
L
1
2
3
4
5
6
1
2
3
4
Terminal
Description Plug in BC terminals
4 (NO)
3 (COM)
2 (L)
1 (N)
Switch Terminal
Common Switch Terminal
Mains Live
Mains Neutral
The DIP switches are found on the rear of
your thermostat and can be used to change
the span (temperature accuracy) of your
thermostat from the default
+/-
0.5°C to
+/-
0.25°C and the programmes 5-2 or 24h.
Changing DIP Switch 2 may cause your boiler
to operate more frequently. The DIP switches
are located on the back of the thermostat.
24H
5-2
+/-0.25
+/-0.5
ON
1
2
Key Function
+Hr
SELECT
SELECT
SET
SET
+
+
+
1. Press once to activate Frost Mode
2. Press for 3 seconds in order to activate Holiday Mode.
Press once to activate/deactivate Boost function
Press once to enter/exit Permanent Override function.
Increase button
Decrease button
Select the clock or programme settings
Press to confirm your settings
Press the buttons for 3 seconds to enter Installer Mode
Press the buttons for 3 seconds to enter Clock Settings
1. Press once to enter in Test Mode for RT510RF
2. Press for 3 seconds to enter/exit Pairing Mode for RT510RF
3. Press once to return to Factory Settings for the RT510
RESET
+Hr
SELECT
SET
3 Sec
3 Sec
3 Sec
Press the three buttons
together for 3 seconds.
dxx
Function
Parameter Description
Default
value
d01
Temperature display
increments
0.1 or 0.5
°
C
Select temperature display
increments
0.5
°
C
d02
Temperature /-3.0
°
C
Calibrate your thermostat
temperature
0.0
°
C
d03
Frost setpoint
5.0
-17.0°C
Set the Frost Point temperature 5.0
°
C
If you are using the RT510RF or RT510BC pack, the pairing between
the thermostat and the receiver/boiler controller is already done.
If you bought an RT510TX and RXRT510 separately then pair as follows.
Please make sure that the Receiver/Boiler Controller is set on Auto.
Begin the pairing process
TEST / PAIRING
SELECT
+Hr
SET
TEST / PAIRING
SELECT
+Hr
SET
TEST / PAIRING
SELECT
+Hr
SET
3 Sec
ON
AUTO
OFF
MANUAL
TEST / PAIRING
SELECT
+Hr
SET
Wait 9 minutes for the timeout
process to be complete.
End the pairing process
3 Sec
ON
AUTO
OFF
MANUAL
TEST / PAIRING
+Hr
SELECT
SET
TEST / PAIRING
+Hr
SELECT
SET
Test the pairing process
If you bought an RXRT510 or RT510TX and intend pairing with other
devices in the 5x5 range, please refer to the Receiver Units manual, or the
relevant manuals available at www.salus-manuals.com
Button Description for RXRT510 Receiver
Button Function
ON
The receiver is enabled, ready for use.
OFF
The receiver is disabled, will not function.
AUTO
The receiver will switch on and off automatically,
as operated by the thermostat.
MANUAL
Providing ON is selected,the receiver will switch
on continuously, overriding the thermostat.
Button Description for RXBC605 Boiler Controller
Button Function
SYNC
The boiler controller will be syncronised with the
thermostat.
AUTO
The receiver will switch on and off automatically,
as operated by the thermostat.
MANUAL
Select in the event of thermostat failure to switch
boiler on continuously, overriding the thermostat.
ON
AUTO
OFF
MANUAL
Installation
RT510 Thermostat
Insert the batteries and
wire up the device.
Terminal
Description
Backplate
Common Terminal
1 (COM)
2 (NC)
Switched Live OFF
3 (NO)
Switched Live ON
Technical Support
T: 44 (0) 1226 323961
Installation
RT510RF (RXRT510)Thermostat and Receiver
1. Wire up the receiver and switch the power on
2. Once the receiver is switched on then insert the batteries into the
thermostat. If using RT510RF pack the devices are already paired.
Now follow Test pairing process to confirm connection between both the
thermostat and receiver. If purchased the devices separately please follow
pairing process.
TEST / PAIRING
SELECT
+Hr
SET
AUTO
ON
OFF
MANUAL
868.0-868.6MHz; <13dBm
06/2017
+Hr
RESET
SELECT
SET
1
1
1
1
1
1
1
1
1
After power up, the
receiver will be in
pairing mode and
the LED will flash red.