Introduction
Button functions
LCD Icon description
Technical specification
Product compliance
Safety Information
Directives: EMC 2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU and RoHS 2011/65/EU.
Full information is available on the website www.saluslegal.com
RT510 / RT510RF is a programmable room thermostat used to control room temperature. Device
launching heating system by shorting terminal blocks, simultaneously informing the action and
showing this information on the LCD display. Extended features allows us to use various operating modes
- automatic (time schedules), manual, frost protection or holiday. Before use please read this manual
carefully. Use only AA 1.5 V alkaline batteries in the thermostat. Place the batteries into the battery slot
located under the cover. Do not use rechargeable batteries.
Use in accordance to national and EU regulations. Use the device as intended, keeping it in dry condition.
Product for indoor use only. Installation must be carried out by a qualified person in accordance to national
and EU regulations.
RT510/RT510TX Thermostat
RXRT510 Receiver
1
6
7
8
9
4
3
2
5
1.
Boost function
2.
Manual Mode
3.
Frost protection / Holiday Mode
4.
Increase button
5.
Decrease button
6.
When in Manual Mode,
ON will turn the boiler on.
7.
When in Manual Mode,
OFF will turn the boiler off.
8.
Receiver operates in automatic mode
according to the thermostat
9.
Receiver output is controlled
by the On/Off slide switch.
1.
Day of the week
2.
Program number
3.
Program indicator
4.
Settings
5.
Temperature measured / set
6.
Boost function
7.
Low battery status
8.
Wireless connection with the receiver
9.
Heating Mode On
10.
Manual Mode On
11.
Holiday Mode On
12.
Frost Protection Mode On
13.
Temperature unit
14.
AM / PM
15.
Clock
2
3
5
6
4
1
15
14
12
13
8
9
11
7
10
RT510 Thermostat
RT510TX Thermostat
Thermostat supply
2 x AA alkaline batteries 2 x AA alkaline batteries
Thermostat rating max
3 (1) A
-
Outputs
Voltage free
NO / COM / NC
terminals
-
Temperature range
5 - 35°C
5 - 35°C
Temperature accuracy
0.1°C or 0.5°C
0.1°C or 0.5°C
Hysteresis
±0.25°C or ±0.5°C
±0.25°C or ±0.5°C
Radio frequency
-
868 MHz
Dimension [mm]
120x96x27
120x96x27
RXRT510 Receiver
Receiver supply
230 V AC
Receiver rating max
16 (5) A
Outputs
Voltage free NO / COM terminals
Radio frequency
868 MHz
Dimension [mm]
96x96x27
Importer:
SALUS Controls plc
Salus House, Dodworth Business Park
Whinby Road, Barnsley S75 3SP,
United Kingdom
DISTRIBUTOR OF SALUS CONTROLS:
QL CONTROLS Sp. z o.o., Sp. k.
Rolna 4,
43-262 Kobielice,
Poland
www.salus-controls.eu
SALUS Controls is a member of the Computime Group.
Maintaining a policy of continuous product development SALUS Controls plc reserve the right to
change specification, design and materials of products listed in this brochure without prior notice.
Installation Manual
Model: RT510
(Wired, electronic thermostat - programmable)
RT510RF
(Wireless, electronic thermostat - programmable)
DIP Switch Settings
The DIP switches are found on the rear of your thermostat.
The DIP switch number 1 is used to change the schedule mode: 5-2
mode (business days + weekend) or for each day separately mode.
DIP switch number 2 is used to change the span (temperature
accuracy) of your thermostat from the default ±0.5°C to ±0.25°C.
This may cause your boiler to operate more frequently.
RT510 Wiring diagram
L
L
L
COM
Thermosta
t
RT510T
X
NO
N
N
N
L
L
M
N
N
M
COM
NO
CO
M
NO
NC
CO
M
NO
NC
or
MAX
3 (1) A
or
Rec
eiv
er
RXR
T510
AC 230 V
AC 230 V
AC 230 V
Rec
eiv
er
RXR
T510
MAX
16 (5) A
Thermosta
t
RT510
Thermosta
t
RT510T
X
Thermosta
t
RT510
OR
L
L
L
COM
Thermosta
t
RT510T
X
NO
N
N
N
L
L
M
N
N
M
COM
NO
CO
M
NO
NC
CO
M
NO
NC
or
MAX
3 (1) A
or
Rec
eiv
er
RXR
T510
AC 230 V
AC 230 V
AC 230 V
Rec
eiv
er
RXR
T510
MAX
16 (5) A
Thermosta
t
RT510
Thermosta
t
RT510T
X
Thermosta
t
RT510
RT510
Thermosta
t
RT510
Thermosta
t
RT510RF Wiring diagram
Setting the time
Note:
If you are using the RT510RF pack, the pairing between the thermostat and the receiver is already done.
L
L
L
COM
Thermosta
t
RT510T
X
NO
N
N
N
L
L
M
N
N
M
COM
NO
CO
M
NO
NC
CO
M
NO
NC
or
MAX
3 (1) A
or
Rec
eiv
er
RXR
T510
AC 230 V
AC 230 V
AC 230 V
Rec
eiv
er
RXR
T510
MAX
16 (5) A
Thermosta
t
RT510
Thermosta
t
RT510T
X
Thermosta
t
RT510
L
L
L
COM
Thermosta
t
RT510T
X
NO
N
N
N
L
L
M
N
N
M
COM
NO
CO
M
NO
NC
CO
M
NO
NC
or
MAX
3 (1) A
or
Rec
eiv
er
RXR
T510
AC 230 V
AC 230 V
AC 230 V
Rec
eiv
er
RXR
T510
MAX
16 (5) A
Thermosta
t
RT510
Thermosta
t
RT510T
X
Thermosta
t
RT510
OR
RT510T
X
Thermosta
t
RT510T
X
Thermosta
t
RXR
T510
Receiv
er
RXR
T510
Receiv
er
RT510 Terminals description
RXRT510 Receiver terminals description
Terminal
Description
1 - COM
Common Terminal
2 - NC
Switched Live OFF
3 - NO
Switched Live ON
Terminal
Description
NO
Switch Terminal
COM
Common Switch Terminal
L, N
Supply (230 V AC)
NO COM L N
24H
5-2
+/-0.25°C
+/-0.5°C
ON
1
2
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
1
3
5
7
9
Press or to select the hour format.
Press the buttons SELECT and SET
together for 3 sec.
Press SELECT to confirm.
Press SELECT to confirm.
Press SELECT to confirm.
Press SET to confirm.
Press or to set the hour.
Press or to set the minutes.
Press or to set day of the week.
Thermostat will return to the main screen.
3 sec 3 sec
I 2018
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
Programming - automatic mode
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
2
4
6
8
10
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
1
3
5
7
9
Use the or button to select day / days
from which you want to start programming.
Use the or button to set the hour
to start the program #1.
Use the or button to set the minutes
to start the program #1.
Use the or button
to set the temperature for program #1.
Follow steps 4-9,
to define programs 2-6.
Press SET button to end programming.
Press the SET button to start programming.
Press SELECT to confirm.
Press SELECT to confirm.
Press SELECT to confirm.
Press SELECT to confirm.
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
In this mode, user can set the schedules for thermostat (temperature setpoints for specific periods of
time). To do this, firstly choose programming mode: “5-2” (business days + weekend) or “24h” (each
day separately) using DIP switch no. 1. Programmed schedules should use all time periods.