The DT600 product is an intelligent temperature controller with built-in OpenTherm (OT) circuit, which can be used for indoor 
ambient temperature regulation in home and office. The user can connect the receiver through the thermostat to control the 
temperature of the specific environment of the home  or office, so as to meet the user’s intelligent needs for the product.

This product complies with the essential requirements and other relevant provisions of Directives EMC 2014/30/EU, 
LVD 2014/35/EU, RED 2014/53/EU and RoHS 2011/65/EU. The full text of the EU Declaration of Conformity is available at the 
following internet address: www.saluslegal.com

Introduction

Product compliance

Safety Information

Use in accordance to national and EU regulations . Use the device as intended , keeping it in dry condition.Product for indoor 
use only. Installation must be carried out by a qualified person in accordance to national and EU requlations.

Technical specification

DT600 Thermostat

DT600RF Thermostat

Thermostat supply

2 x AA alkaline batteries

2 x AA alkaline batteries

Thermostat rating max

5 (3) A

-

OpenTherm terminals

A / B

-

Outputs

Voltage free NC / NO / COM terminals

-

Temperature range

5 °C – 35 °C

5 °C – 35 °C

Temperature accuracy

0.1 °C or 0.5 °C

0.1 °C or 0.5 °C

Control algorithm

ITLC
SPAN ± 0.25 °C  or  ± 0.5 °C
OpenTherm

ITLC
SPAN ± 0.25 °C  or  ± 0.5 °C
OpenTherm

Radio frequency

-

868 MHz

Dimension [mm]

120 x 90 x 29

120 x 90 x 29

DTRX6 Receiver

Receiver supply

230 V AC

Receiver rating max

3 (1) A

OpenTherm terminals

A / B

Outputs

Voltage free NO / COM terminals

Radio frequency

868 MHz

Dimension [mm]

98 x 98 x 25.2

1

2

3

4

5

6

Button functions

DT600 / DT600RF Thermostat

DTRX6 Receiver

8

7

1. 

MENU - enter the menu options, press and hold for 3sec 

 

to return to main screen or to deactivate Boost Mode.

2. 

BOOST - activate Boost Mode.

3. 

MANUAL - activate / deactivate Manual Mode.

4. 

UP - increase the temperature and move through menus.

5. 

OK - confirm changes and enter menus.

6.

   DOWN - decrease the temperature and move through the  

 menus.

7. 

When in manual mode, ON will turn the boiler on

        When in manual mode, OFF will turn the boiler off

8. 

Receiver operates in automatic mode according to 

        the thermostat/Receiver output is controlled by the  
 

On/Off slide switch.

LCD Icon Description

1

6

3

8

2

7

4

9

5

10

12

15

17

11

14

13

16

18

Day of the week

Invalid icon

Program indicator

Manual Mode On

Program number

Invalid icon

Temperature measured/set

Landlord Mode On

Boost function

Holiday Mode On

Frost Protection Mode On

Temperature unit

Clock

Low battery status

Heating Mode On

Wireless connection with the 

receiver (Only for RF thermostat)

AM / PM

Text bar

1

18

17

16

15

14

13

2

3

4

5

6

9

7

10

8

11

12

DT600 Thermostat Terminals Description

DTRX6 Receiver Terminals Description

Terminal

Description

COM

Common Terminal

NO

Switched Live ON

NC

Switched Live OF

A / B

OpenTherm Communication Wire

Terminal

Description

B / A

OpenTherm Communication Wire

NO

Switch Terminal

COM

Common Switch Terminal

L, N

Power Supply (230 V AC)

Use terminals on

the backplate.

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

A

B

AC 230V

3V

X

 AA

DT600RF

BOILER CONNECTION* 

DTRX6

MAX

16(5)A

COM

NO

AC 230V

DT600RF

3V

2 X AA

DTRX6

DT600RF

3V

2 X AA

COM

NO

AC 230V

BOILER CONNECTION* 

DTRX6

MAX

16(5)A

COM

NO

AC 230V

DT600RF

3V

2 X AA

DTRX6

DT600RF

3V

2 X AA

COM

NO

AC 230V

BOILER CONNECTION* 

DTRX6

AC 230V

3V

A

X

 AA

B

DT600 Thermostat

BOILER CONNECTION* 

MAX

3(1)A

AC 230V

AC 230V

3V

NC

NO

COM

X

 AA

3V

NC

NO

COM

X

 AA

DT600 Thermostat

BOILER CONNECTION* 

DT600 Thermostat

MAX

3(1)A

AC 230V

AC 230V

3V

NC

NO

COM

X

 AA

3V

NC

NO

COM

X

 AA

DT600 Thermostat

BOILER CONNECTION* 

DT600 Thermostat

DT600RF Thermostat Wiring Diagram

Note:

 If you are using the DT600RF pack , the pairing between the thermostat and the receiver is already done.

OpenTherm

OR

DT600 Thermostat Wiring Diagram

OpenTherm - Hot Water

Programming - Automatic Mode

OR

Power Up and Configuration

OpenTherm Modulating Control is a method of control used by modern 

heating systems. Instead of switching a boiler on and off at intervals, 

modulating control allows the amount of heat provided by the boiler to 

be controlled to match the varying demand from the thermostat. This 

means the customer has greater system efficiency, energy saving and 

room comfort from our heating controls.

Max boiler temperature settings

To set the max temperature for the connected boiler, follow the below steps :

Please make the receiver connections and power the receiver before inserting the batteries into the thermostat.

1

10

1

4

1

1

4

13

4

7

11

2

5

2

2

5

14

5

8

3

12

3

3

3

6

15

6

9

After inserting the batteries, 

the thermostat will power up.

Press OK to confirm.

Press MENU.

The thermostat will return to 

the main screen. Press any button.

Press MENU.

Press MENU.

Press OK to confirm.

Using UP or DOWN, 

set the hour and then press OK.

Using UP or DOWN, 

set the month and then press OK.

Using UP or DOWN, 

choose the time format.

Using UP or DOWN, enable or

disable DST (Daylight Saving Time).

Using UP or DOWN, navigate to 

Hot Water submenu and press OK.

The text bar indicates that 

hot water is in operation.

Using UP or DOWN, navigate to CH MAX submenu 

and press OK.

Using UP or DOWN adjust the 
PROGRAM and then press OK.

Using UP or DOWN, select the

program type between: 

Using UP or DOWN, set MAX temperature 

for boiler and then press OK to confirm.

Using UP or DOWN, 

select your temperature accuracy.

Using UP or DOWN,

set the minutes and then press OK.

Using UP or DOWN, 

set the day and then press OK.

Press OK to confirm.

Press OK to confirm.

Using UP or DOWN, adjust the 

temperature and then press OK.

The thermostat will return to 

the main screen. Press any button.

Press OK to confirm.

Using UP or DOWN,

set the year and then press OK.

Using UP or DOWN, 

select the week format.

The schedule has 6 time intervals for which different temperatures can be adjusted. You can set 2, 3 or up to 6 temperatures 

per day. You must define all time periods. Here is an example of setting a certain time with a certain temperature.

TPI & SPAN

OpenTherm

TPI & SPAN

2

If you have chosen the OpenTherm electrical connection (A / B),

the device software will automatically adjust to the OpenTherm settings.

To define the chosen TPI or SPAN algorithm, follow the steps in the chapter 

Setting the CONTROL

,

starting with step 2.

OK

OK

OK

16a

16b

16b

If you have chosen the TPI or SPAN 

electrical connection (NO/COM contacts),

using UP or DOWN, choose one of the 

two heating control algorithms, 

TPI or SPAN.

Содержание DT600

Страница 1: ...me Group Maintaining a policy of continuous product development SALUS Controls plc reserve the right to change specification design and materials of products listed in this brochure without prior notice SALUS Controls Units 8 10 Northfield Business Park ForgeWay Parkgate Rotherham S60 1SD Email sales salus tech com ...

Страница 2: ...ormation UseinaccordancetonationalandEUregulations Usethedeviceasintended keepingitindrycondition Productforindoor use only Installation must be carried out by a qualified person in accordance to national and EU requlations Technical specification DT600Thermostat DT600RFThermostat Thermostat supply 2xAAalkalinebatteries 2xAAalkalinebatteries Thermostat rating max 5 3 A OpenTherm terminals A B Outp...

Страница 3: ...or Manual Mode On Program number Invalid icon Temperature measured set Landlord Mode On Boost function Holiday Mode On Frost Protection Mode On Temperature unit Clock Low battery status Heating Mode On Wireless connection with the receiver Only for RF thermostat AM PM Text bar 1 18 17 16 15 14 13 2 3 4 5 6 9 7 10 8 11 12 DT600ThermostatTerminals Description DTRX6 ReceiverTerminals Description Term...

Страница 4: ...rmostat OR DT600ThermostatWiring Diagram OR Power Up and Configuration Please make the receiver connections and power the receiver before inserting the batteries into the thermostat 1 10 4 7 11 5 8 3 12 6 9 After inserting the batteries the thermostat will power up Press OK to confirm Using UP or DOWN set the hour and then press OK Using UP or DOWN set the month and then press OK Using UP or DOWN ...

Страница 5: ... is in operation Using UP or DOWN navigate to CH MAX submenu and press OK Using UP or DOWN adjust the PROGRAM and then press OK Using UP or DOWN select the program type between 5 Using UP or DOWN set MAX temperature for boiler and then press OK to confirm Using UP or DOWN select your temperature accuracy Using UP or DOWN adjust the temperature and then press OK The thermostat will return to the ma...

Страница 6: ...e ON times and low temperature for the OFF times Individual set a daily schedule Press OK to confirm Using UP or DOWN set the month and then press OK Using UP or DOWN set the minutes and then press OK UsingUPorDOWN setthetemperature whichshouldbemaintanedduring holidaymodeandthenpressOK AccordingtosetperiodoftimetheHoliday iconwillappearonthemainscreenand thermostatisworkinginholidaymode Using UP ...

Страница 7: ...ing UP or DOWN select ON or OFF Using UP or DOWN select Optimum START or Optimum STOP Press OK to confirm Optimize function 4a 4b OK OK OK OK OK OK OK OK 3 2a 3a 2b 1 3b 2c 2 Press OK Span is the temperature difference between which thermostat operates and keeps setpoint temperature For example if yousetsetpointtemperatureto20 Candifthehysteresisis 0 5 C heatingwillbeturnedonwhentheroomtemperature...

Страница 8: ...illmaintainselectedtemperature Using UP or DOWN select the due date and then press OK UsingUPorDOWN select ONandpressOK UsingUPorDOWN selectthe duedateandthenpressOK Press OK Now you can check your settings If you want to make a change press UP or DOWN on the relevant screen Hourly temperature Override Mode Hr Manual Mode and setting setpoint temperature OK OK OK OK OK OK Press Hr button to set nu...

Страница 9: ... for the boiler must be powered from a stable voltage source without frequent interruptions or voltage fluctuations outside the standard tolerance The manufacturer is not responsible for identifying or combating the effects of local disturbances ON OFF MANUAL AUTO ON OFF MANUAL AUTO ON OFF MANUAL AUTO Move the left switch to the OFF position with a quick motion and back to the ON position The gree...