background image

DT300, DT300RF

AC 230V

AC 230V

DT300

3V

NC

NO

COM

X

 AA

3V

NC

NO

COM

X

 AA

MAX

5(3)A

BOILER CONNECTION*

DT300

AC 230V

AC 230V

NO

COM

DTRX3

DTRX3

NO

COM

DT300RF

3V

X

 AA

3V

X

 AA

MAX

16(5)A

DT300RF

BOILER CONNECTION*

AC 230V

AC 230V

NO

COM

DTRX3

DTRX3

NO

COM

DT300RF

3V

X

 AA

3V

X

 AA

MAX

16(5)A

DT300RF

BOILER CONNECTION*

AC 230V

AC 230V

DT300

3V

NC

NO

COM

X

 AA

3V

NC

NO

COM

X

 AA

MAX

5(3)A

BOILER CONNECTION*

DT300

Quick Guide

SALUS Controls

Units 8-10, Northfield Business Park

Forge Way, Parkgate,

Rotherham, S60 1SD

Email: [email protected]

SALUS Controls is a member of the Computime Group.

Maintaining a policy of continuous product development SALUS Controls plc reserve the right to change
specification, design and materials of products listed in this brochure without prior notice.

www.salus-controls.com

Issue Date: May 2022

V03

DT300/DT300RF is a digital room thermosat used to control room temperature. Device launching heating system by 
shorting terminal blocks, simultaneously informing the action and showing this information on the LCD display. Before 
use please read this manual carefully. Use only AA 1. 5 V alkaline batteries in the thermostat. Place the batteries into 
the battery holder located on the side of thermostat (see the 

Battery Replacement

 chapter on the back). Do not use 

rechargeable batteries.

This product complies with the essential requirements and other relevant provisions of Directives EMC 2014/30/EU,
LVD 2014/35/EU, RED 2014/53/EU and RoHS 2011/65/EU. The full text of the EU Declaration of Conformity is available 
at the following internet address: www.saluslegal.com

Introduction

Product compliance

Technical specification

Safety Information

Use in accordance to national and EU regulations . Use the device as intended , keeping it in dry condition. Product for 
indoor use only. Installation must be carried out by a qualified person in accordance to national and EU requlations.

Use terminals on

the backplate.

DT300 Thermostat

DT300RF Thermostat

Thermostat supply

2 x AA alkaline batteries

2 x AA alkaline batteries

Receiver supply

-

230 V AC

Thermostat rating max

5 (3) A

-

Receiver rating max

-

16 (5) A

Outputs

Voltage free NC / NO / COM terminals

-

Temperature range

5 - 35°C

5 - 35°C

Dimension [mm]

90 x 90 x 29

90 x 90 x 29

DT300 Thermostat terminals description

DTRX3 Receiver terminals description

Terminal

Description

1 - COM

Common Terminal

2 - NC

Switched Live OFF

3 - NO

Switched Live ON

Terminal

Description

NO

Switch Terminal

COM

Common Switch Terminal

L, N

Power Supply (230 V AC)

LCD Icon description

Legend:

Symbols explanation:

1. 

Heating Mode ON

2. 

Frost Protection Mode ON

3. 

RF signal indicator (only for DT300RF)

4. 

Low battery status

5. 

Temperature unit

6. 

Room / setpoint temperature

2

5

6

1

3

3

1

2

4

4

1. 

Turn on the LCD backlight

2. 

Turn On/Off the Frost Mode

3. 

Increase button

4. 

Decrease button

5. 

When in manual mode, ON will turn the boiler on.

 

When in manual mode, OFF will turn the boiler off.

6. 

Receiver operates in automatic mode according to 

 

the thermostat/Receiver output is controlled by the

 

On/Off slide switch.

Button functions

DT300 Thermostat Wiring Diagram

DT300RF Thermostat Wiring Diagram

DT300 / DT300RF Thermostat

DTRX3 Receiver

OR

OR

6

5

Boiler - Boiler connection*

- Boiler’s contacts for ON / OFF thermostat
(according to the boiler’s instructions )

L, N 

- Power supply 230V

NO, COM, NC 

- Voltage-free output

Pump

Valve actuator

- Fuse

Содержание DT300

Страница 1: ...mail sales salus tech com SALUS Controls is a member of the Computime Group Maintaining a policy of continuous product development SALUS Controls plc reserve the right to change specification design and materials of products listed in this brochure without prior notice www salus controls com Issue Date May 2022 V03 ...

Страница 2: ... 30 EU LVD 2014 35 EU RED 2014 53 EU and RoHS 2011 65 EU The full text of the EU Declaration of Conformity is available at the following internet address www saluslegal com Introduction Product compliance Technical specification Safety Information Use in accordance to national and EU regulations Use the device as intended keeping it in dry condition Product for indoor use only Installation must be...

Страница 3: ...eatingModeON 2 FrostProtectionModeON 3 RFsignalindicator onlyforDT300RF 4 Lowbatterystatus 5 Temperatureunit 6 Room setpointtemperature 2 5 6 1 3 3 1 2 4 4 1 TurnontheLCDbacklight 2 TurnOn OfftheFrostMode 3 Increasebutton 4 Decreasebutton 5 When in manual mode ON will turn the boiler on Wheninmanualmode OFFwillturntheboileroff 6 Receiver operates in automatic mode according to the thermostat Recei...

Страница 4: ... COM DT300RF 3V 2 X AA 3V 2 X AA MAX 16 5 A DT300RF BOILER CONNECTION AC 230V AC 230V DT300 3V NC NO COM 2 X AA 3V NC NO COM 2 X AA MAX 5 3 A BOILER CONNECTION DT300 Legend Symbols explanation DT300ThermostatWiring Diagram DT300RFThermostatWiring Diagram OR OR Boiler Boiler connection Boiler s contacts for ON OFF thermostat according to the boiler s instructions L N Power supply 230V NO COM NC Vol...

Страница 5: ...herthanthemeasuredtemperature When the snowflake icon is displayed then it means that the frost protection mode is active To exit sleep mode press twice any button To enter sleep mode press and hold and for 3 seconds Press or to set the temperature Press button to turn ON OFF frost protection The Frostpoint temperature can be reviewed by pressing the button once but can only be changed in Installe...

Страница 6: ...esource withoutfrequentinterruptionsorvoltage fluctuations outside the standard tolerance The manufacturer is not responsible for identifying or combating theeffectsoflocaldisturbances Move the left switch to the OFF position with a quick motion and back to the ON position Press and hold PAIRING TEST button behind the back cover cover for 3 seconds Press and hold PAIRING TEST button behind the bac...

Страница 7: ...onds Installer Mode Battery replacement Reset of the DT300 DT300RF thermostat 3 sec 3 sec 3 sec Press to edit the parameter To change the parameter value use and buttons dxx Function Parameter value Default value d01 Temperature display increments 0 1 C or 0 5 C 0 5 C d02 Temperature offset 3 0 C 0 0 C d03 Frost protection setpoint temperature 5 0 C 17 0 C 5 0 C d04 TPI or SPAN algorithm selection...

Отзывы: