25
Overlap
Set the overlap amount of fiber pushing, if the [pre-discharging
strength] is low, then smaller [overlap] is recommended and vice
versa.
Clean discharge time
The clean discharge can burn the tiny dust on the surface of the
fiber in a small discharge cycle, and the discharge time can be
changed by this parameter.
Clean discharge strength Set clean discharge ARC strength.
Prefabricated discharge
strength
Set the pre-discharge strength from the start of discharging to fiber
pushing. If [pre-discharging strength] is set too low, then the axial
deviation of the fiber will occur when the fiber cleaving angle is
relatively poor. If too high, excessive melting of optical fiber ends
will lead to greater loss of fusion.
Prefabricated discharge
time
It is possible to set the same discharge time from the start to the
start of the fiber advance, and the long [pre-fusing discharge time]
and the high [pre-fusing discharge intensity] result in the same
result.
Содержание SFS-7000 Series
Страница 20: ...8 Chapter 4 Basic Operation 4 1 Appearance overview...
Страница 23: ...11 4 3 Power on Press the button on and wait for it to enter into working platform...
Страница 32: ...20...
Страница 38: ...26 Strength of ARC Set the ARC strength Splicing ARC time Set the ARC time...
Страница 45: ...33 Choose and edit the parameter after which press Confirm...