background image

Shortcut menu

Date &Time

Flashlight

Battery

TF card

Enter  the  main  menu  after  power  on,  there  are  12 

function modules. Press the direction key to select the 

module, and then press the "OK" key or directly press 

the  function  icon  to  enter  the  corresponding  function 

interface.

Press  the  "Shortcut  menu"  icon  to  enter  the  quick 

operation  menu,  and  press  different  function  icons  to 

enter the corresponding function interface or realize the 

corresponding operation function.

Print Screen: 

Capture the current interface, the picture 

is  automatically  saved  in  the  instrument,  and  the  file 

name is the time when the screenshot is generated.

OTDR is an optoelectronic integrated instrument made 

of  Rayleigh  scattering  and  Fresnel  reflection  when 

optical signal is transmitted in optical fiber. It is widely 

used in the maintenance, construction and monitoring 

of  optical  cable  lines.  It  can  measure  the  length  of 

optical fiber, transmission attenuation of optical fiber, 

attenuation of connector and fault location.

Auto  OTDR: 

it  only  needs  to  set  the  wavelength  and 

measurement time, and other parameters are automat-

ically selected by the instrument to complete the test. 

For  the  specific  meaning  and  explanation  of  each 

parameter, please refer to "expert OTDR".

Expert  OTDR: 

parameters  such  as  wavelength,  test 

range and pulse width shall be set.

The  test  results  are  more  accurate  by  selecting  the 

appropriate  measurement  parameters  in  the  expert 

mode. You can zoom in on the curve to see the details of 

each event.

Wave:

 the emit wavelength, which can be measured at 

1310nm or 1550nm.

Test range:

range setting is based on the actual length 

of  the  optical  fiber  to  select  the  corresponding 

predefined range, must be greater than the length of the 

measured  optical  fiber,  usually  required  to  be  set  to 

about twice the length of the measured optical fiber.

Auto  test:

  OTDR  automatically  matches  the  most 

suitable parameters for the current test, and the select-

ed  values  of  test  range  and  pulse  width  cannot  be 

modified.

Manual mode:

 set the value of measurement range and 

pulse width manually.

Pulse  width: 

refers  to  the  time  width  of  the  optical 

pulse  signal  emitted  during  test.  The  larger  the  pulse 

width, the stronger the optical power injected into the 

optical  fiber,  the  stronger  the  backscattering  signal  of 

the optical fiber is, and the farther the effective detec-

tion  distance  of  the  OTDR  can  be.  However,  the  large 

pulse width will cause saturation of the initial reflection 

signal and  a large blind area. The choice of pulse width 

is related to the length of the optical fiber. The longer 

the length, the larger the pulse width, which can only be 

modified in real-time/average measurement mode.

Threshold settings

Event loss threshold:

 set the loss threshold of connec-

tion point, fusion point or macro bend in the link that 

can be tested, between 0.2~30dB, and the default value 

is  0.2dB.  Events  larger  than  the  set  threshold  will  be 

listed in the event table, or those will be ignored.

Reflection threshold: 

set the return loss threshold of 

the  link  reflection  events  that  can  be  tested,  ranging 

from 10dB to 60dB, and 40dB by default.

End threshold: 

set end loss at the end of the link that 

can be tested, ranging from 1~30dB, 10dB by default.

Eligibility criteria

Set the judgment value for the average loss of connec-

tion/fusion/bending/link. If it is less than the  value, it is 

judged as "PASS", otherwise it is "FAIL".

Connection loss: 

reflection event, refers to flange, SC, 

LC and other joints;

Welding loss: 

non reflective event, refers to fusion;

Bending  loss:

  non  reflective  events  caused  by  fiber 

bending, need to be tested at two wavelengths at once;

Average  loss: 

the  loss  value  per  kilometer  of  the  link 

under test.

Select correct parameter, the test results such as curve 

and event list will be displayed after test completed.

IOR: 

provided by optical cable or  fiber manufacturer.It is 

the  key  parameter  for  calculating  the  distance,  and  can 

not be set arbitrarily.

Test time:

  it is used in the average test mode. The longer 

the test time is, the better the signal-to-noise ratio of the 

signal is improved, and the more accurate the test result is. 

The  user  should  choose  the  test  time  reasonably.  It  is 

proportional to the dynamic.

Unit: select the required unit, there are three options for 

km/kfeet/miles.

Charging indicator
Power on status indicator

press less than 2s to turn on the machine, pr.ess more than 

2s to pop up the shutdown confirmation pop-up window;

When power on, short press to turn on or off the flashlight.

  

Direction key   

up, down, left and right

      

SET key    

enter the OTDR parameter 

setting interface

  

ESC key    

exit current function

  

Zoom control / AB cursor switch key    

  

Test / Stop key

  

OTDR: press to start or stop test

Flashlight
RJ45 Cable Tracker port

OTDR/LS port

Dust cover
4.3 inch color LCD
Function keys

Top

Bottom

Main view

OPM port

VFL port

PREFACE

This series of OTDR is a multi-functional optical measuring instrument, which integrates auto OTDR, 

expert  OTDR,  event  map,  optical  power  meter,  visual  fault  location,  power  adjustable  stable  light 

source,  end  face  detection,  optical  loss  test,  cable  line  length  /  sequence  test,  cable  tracking  and 

other functions. It has touch screen and heys. It is the right assistant for optical cable construction, 

installa-tion and maintenance, project acceptance and on-site repair.

When using the instrument, do not look directly at the laser output port or the end of the optical fiber 

with your eyes, avoid eye damage! Except for 1625nm/1650nm, all the others are off-line test wave-

lengths,  which  will  cause  damage  to  internal  components  of  the  instrument  if  forced  to  use!  Any 

change or modification not explicitly permitted in this manual will deprive you of the right to operate 

the equipment. To reduce the risk of fire or electric shock, do not expose the equipment to thunder-

storm or humid environment. In order to prevent electric shock, please do not open the shell. It must 

be repaired by qualified personnel designated by the manufacturer

Battery: 

the  battery  is  a  special  polymer  lithium  battery,  the  charging  voltage  is  5V/2A,  and  the 

charging temperature range is 0 ℃~ 50 ℃. When the ambient temperature is too high, the charging 

will automatically terminate. The battery should be charged every one month to avoid long storage 

time and failure of battery due to self discharge. The temperature range of battery during long-term 

storage is: - 40 ℃ ~ 50 ℃.

Please use the special adapter attached with the instrument box and use the external power supply 

in strict accordance with the specifications, otherwise the equipment may be damaged.

End Face Cleaning: 

Before testing, clean the end face of the tested fiber joint with alcohol cotton.

LCD screen: 

the display of this series of instruments is 4.3 inch color LCD. In order to maintain good 

viewing effect, please keep the LCD screen clean. When cleaning, wipe the LCD screen with soft fabric.

Summary

Thank you very much for purchasing and using this series of optical time domain reflectometers. 
This manual mainly contains the common operation and maintenance information of the instru-
ment, as well as the common troubleshooting guide and other information. In order to facilitate 
your use, please read the contents of this manual carefully before operating the instrument, and 
follow the instructions of this manual correctly.
This manual is only used with this instrument. Any company or person is allowed to tamper, copy 
and disseminate the contents of this manual for commercial purposes without the authorization 
of the company.
The contents of this manual are subject to change without notice. If you have any questions, 
please call the supplier, we will provide you with the best service!

SET

ESC

ON

CHARGE

1.

Auto OTDR

System

Expert OTDR

Event Map

End Face

Inspector

          File

Management

  Optical

Loss Test

OPM

dB/dBm/mW

VFL

650nm

Home

2020-10-20  09:25

Laser Source

RJ45 Sequence

   RJ45 Length 

         RJ45 

Digital Tracker

2020-10-20  09:25

AUTO

Auto test

Menu

Home

Flashlight

VFL

File

Print Screen

Power Off

Exit

0.0

10

20

30

40

50

60

70

80

90

4.0

8.0

12.0

16.0

20.0

24.0

28.0

32.0

/dB

/km

1310nm

5s

Auto test  1550nm  100km  10000ns    

AutoTest

Settings

Exit

Zoom

Files

Save

Test

5.

Expert OTDR

6.

Parameter setting

4.

Auto OTDR

3.

Main interface

2.

Function keys

1.

Host

Cursor A

0.0

4.0

8.0

12.0

16.0

20.0

24.0

28.0

32.0

/dB

/km

37.56813m  19.256dB

71.25212m  10.251dB

A

B

Auto test  1550nm  100km  10000ns    

1550nm

10000ns

Real Test

Avg. Test

AutoTest

100km

5s

1:1

1310nm

Wave

1550nm

Wave

1310nm

10000ns

5s

64km

Range

Pluse Width

Avg. Time

Refractive Index

0km

0km

Transmitting cable

End cable

km

Unit

2020-10-20 09:25

Test settings

Exit

Test

Settings

     Pass

Criterion

  Analysis

Threshold

Default

8.

OTDR-Curve

7.

Threshold/Criterion

9.

OTDR-File save

10.

File Operation

Settings

Exit

CursorA

Zoom

Files

Save

Curve zoom

Press the [zoom] menu to enter the zoom in and zoom 

out mode.

      /       Zoom in or out in X direction

      /       Zoom in or out in Y direction

Press [1:1] to return to the original scale display

Event list

List: 

the tested results are displayed in the form of a list.

Total length:

 the total length of the link under test.

Total loss: 

the total loss of the link under test.

Slope: 

the  loss per kilometer of the link under test.

Total events: 

the total number of events, the number of 

passed events and the number of failed events of the 

link under test.

In the event list:

NO.: 

 the order of the current event.

Type: 

the type of the current event.

Distance:

 the location of the current event.

After  the  measurement,  press  [save]  to  save  the  file, 
enter the file name, and press [enter] to save the file. 
You can also press [Fastsave] to save the file. The file is 
saved in a folder named the same day’s date.
Auto save: open the auto save function, the file name 
will be automatically generated according to the rules;

File  naming  method 

(only  valid  for  "auto  save"  and 

"one click save"):
①+④: file name + fiber number naming, fiber number 
increasing in order;
①+②+④:  file  name  +  wavelength  +  fiber  number 
naming, fiber number increasing in order;
①+②+③+④:  file  name  +  wavelength  +  pulse  width  + 
fiber number, and the fiber number increases in order.
File name: enter the file name manually;

Optical  fiber  code  ID: 

the  optical  fiber  number  and 

code set when the line is initially laid;

Location A:

Link start point location

Location B:

Link termination point location

Direction:

Optical fiber test direction,from A to B,

from B to A;

Operator: 

enter the name of the tester.

File operation

All the test curves are saved in the standard SD 

card of the instrument. Press [File] to enter the 

file operation interface. You can open, delete and 

rename files.

Segment: 

the distance between the previous event and 

the current event.

Loss: 

the loss of the current event.

Total loss: 

the loss from the starting point to the current 

event.

Slope: 

the loss per kilometer from the starting point to 

the current event.

Reflection: 

the return loss of the current event.

Back

File naming

Naming Type

File name

Autosave

Yes

Fiber ID

Location A

Location B

Direction

Operator

otdr

2020-10-20 09:25

Save

① + ④

① + ② + ④

① + ② + ③ + ④

① File name
② Wavelength
③ Pulse Width
④ Fiber ID

Back

Select all

Rename

Delete

Storage Card

20200702

20200521

20200929

2020-10-20 09:25

File Operation

Device Catalog

File List

20200421

File name

76 Files

Date

Page 1 / of  8

No.

20200421-1318OTDR.bmp

2020-04-21 13:18

2020-04-21 13:25

2020-04-21 13:27

OTDR-1550-500ns-001.sor

OTDR-1550-500ns-002.sor

1

2

3

2020-04-21 13:32

OTDR-1550-500ns-003.sor

4

2020-04-21 14:42

OTDR-1550-2000ns-001.sor

5

2020-04-21 14:58

OTDR-1550-2000ns-002.sor

6

2020-04-21 15:26

OTDR-1550-2000ns-003.sor

7

2020-04-23 16:32

OTDR-1550-5000ns-001.sor

8

2020-04-23 16:45

OTDR-1550-5000ns-002.sor

9

2020-04-23 16:56

OTDR-1550-5000ns-003.sor

10

Please do not make online test except online wavelengths!

OTDR&LS

VFL

OPM

RJ45 Sequence/Length port

RJ45 Sequence test remote 

TF card
Type C USB

2020-10-20 09:25

Test Settings

Auto

Event Loss Thre.

Customize

Loss Threshold

Auto

Auto

Auto

Reflectance Threshold

End of Fiber Threshold

Backscatter Coefficient

0.20dB

Test

Exit

Settings

  Analysis

Threshold

Default

Pass Criterion

Pass Criterion

2020-10-20 09:25

Test Settings

Connection Loss

0.20    

dB

Splicing Loss

0.20dB

Average Loss

1310nm

1550nm

0.25dB

0.40dB

Bending Loss

dB

Link Loss

dB

3.00

32.00

1

37.56813

0.00000

8.176

0.195

40.22

0.85

2

71.25212

33.68399

15.418

0.215

43.26

--

NO. Type Distance  km

Section(km)

Loss  dB Total-L  dB Avg.L  dB/km Return dB

10

20

30

40

50

60

70

80

90

0.0

4.0

8.0

12.0

16.0

20.0

24.0

28.0

32.0

/dB

/km

37.56813m  19.256dB

71.25212m  10.251dB

A

B

平均  1550nm  100km  10000ns    

1:1

10

20

30

40

50

60

70

80

90

0.0

4.0

8.0

12.0

16.0

20.0

24.0

28.0

32.0

/dB

/km

37.56813m  19.256dB

71.25212m  10.251dB

A

B

Auto test  1550nm  100km  10000ns    

1:1

10

20

30

40

50

60

70

80

90

Due to the need of design improvement, the contents are subject to change without notice.

SET

ESC

ON

CHARGE

ON

CHARGE

The curve and event list are displayed 

at once.

Link results are summarized to a list.

Switch to event icon display mode.

Save current curve file quickly.

Enter parameter setting interface.

Warning

Attentions

According to the OTDR waveform, combine 

with  the  direction  key  operation;  In  the 

switch curve scaling, A/B cursor movement 

function.

Power ON/OFF key

Attention

Please do not make online test except online wavelengths!

Attention

Curve

List

Event Map

FastSave

FastSet

Section   km

Test

Settings

  Analysis

Threshold

Default

Exit

Settings

Exit

Zoom

Files

Save

FastSet

FastSet

Curve

Curve

List

List

Event Map

Event Map

FastSave

FastSave

Settings

Curve

List

Event Map

FastSave

     Pass

Criterion

     Pass

Criterion

S2106S

S2106S

Отзывы: