Salto KPB22 Series Скачать руководство пользователя страница 1

All contents current at time of publication.

SALTO Systems S.L. reserves the right to change availability of any

item in this catalog, its design, construction, and/or materials.

P-210137 -      -ED.08/06/2010

ADAPTER KIT FOR

ADAPTER KIT FOR

2                    Exterior Plate 3                 Battery Holder

11                      Battery Cover

12 To Fix, Counter Clockwise

P

L

C

Eixxx...

4                                    M5 DIN 7985 PZ

9             Selfdrilling Screw DIN 7504 PH

6                               M5 DIN7991 ALLEN

01015

BOLT ENLANGER

ONLY FOR  P > 69

30÷1

20

COMPATIBLE

MODELS

CISA   59800

01465-01

Panic Bar

MODELOS COMPATIBLES

E

I

Eng

1

5          Bottom Washer

KPB22xx..

Rim Exit Device

follow user manual

AT THIS POINT DO NOT

CLOSE THE DOOR

TEST THE LOCK FIRST

INSIDE

OUTSIDE

67

40

EXTERNAL ELECTRONIC ESCUTCHEONS

1

2

3

12

Installation Secuence             .......

®

* MONTAJE BARRA

 ANTIPÁNICO CISA    59800 SEGUN

 INSTRUCCIONES DEL FABRICANTE

* MONTAGIO MANIGLIONI

ANTIPANICO CISA    59800 SECONDO

LE ISTRUZIONI DEL FABRICANTE

* SEE CISA   59800

PANIC BAR INSTALLATION

INSTRUCTIONS

E

I

Eng

®

®

®

MODELLO COMPATIBILE

01406-01-ff

SP00159-10

SP00095-3020

SP00095-4020

SP00095-5020

SP00095-5520

(x30)

(x20)

(x20)

SP01126-20

(x20)

Cut the Spindle

see instructions

1/2

Ei650m00ffH7

Ei6E0m00ffH7

Ei660m00ffH7

Ei6P0m00ffH7

8

7

10                               LR 03

4                                    M5 DIN 7985 PZ

P

 (Puerta)

 

Door mm

 / Door (inch)

Length 

 mm

(Inch)

 BOLT 

EXTENSION   

SUPLEMENTO

35<43mm (1-3/8"<1-11/16")

30mm (1-3/16")

44<52mm (1-3/4"<2-1/16")

40mm (1-9/16" )

53<62mm (2-1/16"<2-7/16")

50 (2")

63<68mm (2-1/2"<2-11/16")

55 (2-3/16")

69<74mm (2-3/4"<2-15/16")

30mm (1-3/16")

1

75<84mm (2-15/16"<3-5/16)

40mm (1-9/16" )

1

85<94mm (3-3/8"<3-11/16)

50 (2")

1

95<99mm (3-3/4"<3-7/8")

55 (2-3/16")

1

100<105mm (3-15/16"<4-1/8")

30mm (1-3/16")

2

106<115mm (4-3/16"<4-1/2")

40mm (1-9/16" )

2

116<120mm (4-9/16"<4-3/4")

50 (2")

2

_

00993-C7-1

1401

*

210118.05

FOR ELECTRONIC ESCUTCHEON

Length

(1) M5 x Length DIN 7985

(3) M5 x Length DIN 7991

(1) Ø

3,9x19 DIN 7504

(?) BOLT EXTENSION

1436-30/40/50/55

(x20)

(x20)

*

2                  Exterior Plate

    P

L

C

Eixxx...

4                                        M5 DIN 7991 ALLEN

BOLT ENLANGER

ONLY FOR  P > 66

30÷1

20

CISA   59810-59815

01465-01

Panic Bar

1

KPB23xx..

Multi Point Rim Exit Device

INSIDE

OUTSIDE

67

1

2

3

15

Installation Secuence             .......

®

SP00159-10

(x30)

Cut the Spindle

see instructions

8

01402

01015

01400

01406-02-ff

6            Wire Cover

5            Top Washer 10                 Battery Holder

11             Selfdrilling Screw DIN 7504 PH

13                     Battery Cover

14 To Fix, Counter Clockwise

12                               LR03

 

15        Cut out to specified size

Corte del protector de la falleba

Eng

7

E

I

Taglio della copriasta

00993-C7-1

3          Bottom Washer

1401

  ** For door thickness (P)

 over 65mm, Use special

wire SP01045-350

Eng

** Para puertas de espesor

(P) mayores de 65mm,

Utilice el cable especial

SP01045-350

E

** Per porte di spessore (P)

maggiore di 65mm, Utilizzare il

cavo  speciale SP01045-350

I

P

 (Puerta)

 

Door mm

 / Door (inch)

Length 

 mm

(Inch)

 BOLT 

EXTENSION   

SUPLEMENTO

35<42mm (1-3/8"<1-11/16")

30mm (1-3/16")

43<52mm (1-11/16"<2-1/16")

40mm (1-9/16" )

53<61mm (2-1/16"<2-3/8")

50 (2")

62<66mm (2-7/16"<2-5/8")

55 (2-3/16")

67<72mm (2-5/8"<2-13/16")

30mm (1-3/16")

1

73<76mm (2-7/8"<3")

35mm (1-3/8" )

1

77<82mm (3"<3-1/4")

40mm (1-9/16" )

1

83<87mm (3-1/4"<3-7/16")

45 (1-3/4")

1

88<92mm (3-1/2"<3-5/8")

50 (2")

1

93<97mm (3-11/16"<3-13/16")

55 (2-3/16")

1

98<103mm (3-7/8"<4-1/16")

30mm (1-3/16")

2

104<108mm (4-1/8"<4-1/4")

35mm (1-3/8" )

2

109<113mm (4-5/16"<4-7/16")

40mm (1-9/16" )

2

114<118mm (4-1/2"<4-5/8")

45 (1-3/4")

2

119<120mm (4-11/16"<4-3/4")

50 (2")

2

_

SP01126-20

(x20)

* MONTAJE BARRA

 ANTIPÁNICO CISA    59810 SEGUN

 INSTRUCCIONES DEL FABRICANTE

* MONTAGIO MANIGLIONI

ANTIPANICO CISA    59810 SECONDO

LE ISTRUZIONI DEL FABRICANTE

* SEE CISA   59810 PANIC BAR

INSTALLATION INSTRUCTIONS

E

I

Eng

®

®

®

**

COMPATIBLE

MODELS

MODELOS COMPATIBLES

E

I

Eng

EXTERNAL ELECTRONIC ESCUTCHEONS

MODELLO COMPATIBILE

Ei650m00ffH7

Ei6E0m00ffH7

Ei660m00ffH7

Ei6P0m00ffH7

Length

FOR ELECTRONIC ESCUTCHEON

(4) M5 x Length DIN 7991

(2) Ø

3,9x19 DIN 7504

(?) BOLT EXTENSION

210118.05

9

1436-30/35/40/45/50/55

Only Wireless Models:

-Exit detection depending of the panic bar model.

-Panic bars with no exit detection, will cause an  intrusion alarm

each time the door is opened from inside.

Sólo Modelos Wireless:

-La detección de salida depende del modelo de barra antipanico.

-Barras antipanico sin detector de salida, pueden causar una

alarma de intrusion cuando la puerta sea abierta desde el interior.

Eng

E

Only Wireless Models:

-Exit detection depending of the panic bar model.

-Panic bars with no exit detection, will cause an  intrusion alarm

each time the door is opened from inside.

Sólo Modelos Wireless:

-La detección de salida depende del modelo de barra antipanico.

-Barras antipanico sin detector de salida, pueden causar una

alarma de intrusion cuando la puerta sea abierta desde el interior.

Eng

E

follow user manual

AT THIS POINT DO NOT

CLOSE THE DOOR

TEST THE LOCK FIRST

Отзывы: