FAULTS, CAUSES AND REMEDIES
Faults
Causes
Remedies
Pump
overheats
and seizes
- Pump not primed or filled with liquid
Check for complete filling
- Insufficient margin between suction pressure and vapor pressure
Check NPSH
A
> NPSH
R
, proper submergence, losses at strainers and
fittings
- Operation at very low capacity
Measure the value and check minimum permitted.
Remedy or call Salmson
- Misalignment due to pipe strain
Check the flange connections and eliminate strains using elastic
couplings or a method permitted
- Rotating part rubbing on stationary part internally
Check and consult Salmson if necessary
- Bearings worn
Replace bearings
- Shaft running off center because of worn bearings or misalignment
Check misalignment and correct it if necessary. If alignment satisfactory
check bearing for excessive wear
- Impeller out of balance resulting in vibration
Check and consult Salmson
- Excessive thrust caused by a mechanical failure inside the pump
Check wear condition of impeller, its clearances and liquid passages
Bearings
have short
life
- Operating at high capacity
Measure the value and check maximum permitted.
Remedy or call Salmson
- Misalignment due to pipe strain
Check the flange connections and eliminate strains using elastic
couplings or a method permitted
- Shaft bent
Check shaft runouts are within acceptable values
Consult Salmson
- Rotating part rubbing on stationary part internally
Check and consult Salmson if necessary
- Bearings worn
Replace bearings
- Shaft running off center because of worn bearings or misalignment
Check misalignment and correct it if necessary. If alignment satisfactory
check bearing for excessive wear
- Impeller out of balance resulting in vibration
Check and consult Salmson
- Excessive thrust caused by a mechanical failure inside the pump
Check wear condition of impeller, its clearances and liquid passages
- Excessive grease in ball bearings
Check method of regreasing
- Lack of lubrication for bearings
Check hours ruin since last change of lubricant, the schedule and its
basis
- Improper installation of ball bearings (damage during assembly, incorrect
assembly, wrong type of ball bearings etc )
Check method of assembly, possible damage or state of cleanliness
during assembly and type of bearing used. Remedy or consult Salmson if
necessary
- Damaged bearing due to contamination
Check contamination source and replace damaged ball bearings
- Motor running too slow
Check motor terminal box connections and voltage
Pump
vibrates or
is noisy
- Pump or suction pipe not completely filled with liquid
Vent and /or prime
- Suction lift too high or level too low
Check NPSH
A
> NPSH
R
, proper submergence, losses at strainers and
fittings
- Insufficient margin between suction pressure and vapor pressure
Check NPSH
A
> NPSH
R
, proper submergence, losses at strainers and
fittings
- Foot valve too small
Investigate replacing the foot valve
- Foot valve partially clogged
Clean the foot valve
- Inlet of suction pipe insufficiently submerged
Check out system design
- Operation at very low capacity
Measure the value and check minimum permitted.
Remedy or call Salmson
- Operating at high capacity
Measure the value and check maximum permitted.
Remedy or call Salmson
- Misalignment due to pipe strain
Check the flange connections and eliminate strains using elastic
couplings or a method permitted
- Improperly designed foundations
Check setting of baseplate : tighten, adjust, grout base as required
- Shaft bent
Check shaft runouts are within acceptable values
Consult Salmson
- Rotating part rubbing on stationary part internally
Check and consult Salmson if necessary
- Bearings worn
Replace bearings
- Impeller damaged or eroded
Replace or consult Salmson for improved material selection
- Shaft running off center because of worn bearings or misalignment
Check misalignment and correct it if necessary. If alignment satisfactory
check bearing for excessive wear
- Impeller out of balance resulting in vibration
Check and consult Salmson
- Excessive thrust caused by a mechanical failure inside the pump
Check wear condition of impeller, its clearances and liquid passages
- Excessive grease in ball bearings
Check method of regreasing
- Lack of lubrication for bearings
Check hours ruin since last change of lubricant, the schedule and its
basis
- Improper installation of ball bearings (damage during assembly, incorrect
assembly, wrong type of ball bearings etc )
Check method of assembly, possible damage or state of cleanliness
during assembly and type of bearing used. Remedy or consult Salmson if
necessary
- Damaged bearing due to contamination
Check contamination source and replace damaged ball bearings
- Wrong direction of rotation
Reverse two phases at motor terminal box
- Motor running too slow
Check motor terminal box connections and voltage
Mechanical
seal
has
short life
- Misalignment due to pipe strain
Check the flange connections and eliminate strains using elastic
couplings or a method permitted
- Shaft bent
Check shaft runouts are within acceptable values
Consult Salmson
- Bearings worn
Replace bearings
- Shaft sleeve worn or scored or running off center
Check and renew defective parts
- Mechanical seal improperly installed
Check alignment of faces or damages parts and assembly method used
- Incorrect type of mechanical seal for operating conditions
Consult Salmson
- Shaft running off center because of worn bearings or misalignment
Check misalignment and correct it if necessary. If alignment satisfactory
check bearing for excessive wear
- Impeller out of balance resulting in vibration
Check and consult Salmson
- Abrasive solids in liquid pumped
Check and consult Salmson
- Internal misalignment of parts preventing seal ring and seat from mating
properly
Check and consult Salmson
- Mechanical seal was run dry
Check mechanical seal condition and source o f dry running and repair
- Internal misalignment due to improper repairs causing impeller to rub
Check method of assembly, possible damage or state of cleanliness
during assembly.
Remedy or consult Salmson if necessary
Mechanical
- Misalignment due to pipe strain
Check the flange connections and eliminate strains using elastic
couplings or a method permitted
Содержание NEX
Страница 2: ......
Страница 27: ...FRAN AIS 27 12 1 1 PLAN EN COUPE Roue ouverte Roue aubes invers es...
Страница 29: ...FRAN AIS 29 13 DECLARATION CE...
Страница 30: ...FRAN AIS 30...
Страница 53: ...ENGLISH 25 12 1 1 SECTIONAL DRAWING Open impeller Reverse vane impeller...
Страница 55: ...ENGLISH 27 13 EC DECLARATION OF CONFORMITY...
Страница 56: ...ENGLISH 28...
Страница 59: ...5 1 1 1 2 2 1 2 2 SALMSON 2 3 2 4 2 4 1 25 68 5 C 2 4 2...
Страница 60: ...6 2 5 2 6 Salmson 2 7 2 8 2 9 ATEX...
Страница 62: ...8 2 9 7 2 9 8 2 9 9 3 3 1 3 2 3 3...
Страница 63: ...9 6 Salmson 3 4 25 3 4 1 4 NEX 5 5 1 NEX...
Страница 69: ...15 0 4 7 1 2 1 2 3 1 2 3 4 5 6 7 8 7 1 3 7 1 4 0 2 1...
Страница 70: ...16 Parallel Angular 7 2 7 2 1 7 2 2 L 2 3 7 2 3...
Страница 71: ...17 8 10 2 NPSHR NPSHA 7 2 4 3 3 10 0 35 2 0 7 7 3 230 400 400 400 690 690 60079 14...
Страница 72: ...18 7 3 1 Y 230 400 400 690 7 3 2 U 7 3 3 U 3 7 3 4 7 4 850 dU dt 2500 ATEX NPSHR NPSHA...
Страница 73: ...19 40 55 8 8 1 2 1 8 2 8 3 1 2 3 4 20 30 5 8 4 HMT P 100 SG 9 806 SG 7 1 4...
Страница 74: ...20 125 P 0 5 P P 0 5 0 1 0 2 3 4 4 140 20 40 8 5 Salmson 9 9 1 9 2...
Страница 86: ...32 11 12 12 1 12 1 1...
Страница 89: ...35 13...