25.  WARRANTY

1. All equipment manufactured in our factory is checked in operating conditions and tested befor delivery. Test protocol is supplied together with 

the unit. The equipment is shipped in good working order and condition to the direct client. The unit is warrantied for the period of two years from 

the invoice date.

2. If equipment is found to have been damaged during transportation, a claim should be made against carrier, as we assume no responsibility for 

such damage.

3. This warranty does not apply:

3.1. when transportation, storage, installation and maintenance instructions of the unit are violated;

3.2. when the equipment is improperly maintained, mounted - inadequate maintenance; 

3.3. when the equipment without our knowledge and permission has been upgraded or unskilled repairs were made;

3.4. when the unit was used not for its original purpose.

3.5. Company SALDA UAB is not responsible for potential loss of property or personal injury in cases where AHU is manufactured without a 

control system and the control system will be installed by the client or third parties. The manufacturer’s warranty does not cover devices that 

will be damaged by installing the control system.

4. This warranty does not apply at these malfunction cases:

4.1. mechanical damage; 

4.2. damage caused by entering outside objects, materials, liquids; 

4.3. damage caused by natural disaster, accident (voltage change in the electricity network, lightning, etc..).

5. The company assumes no liability for its products either directly or indirectly damage, if the damage is caused by failure to comply with instal-

lation and mounting regulations, deliberate or careless users or third-party behavior.

These conditions are readily discernable when the equipment is returned to our factory for inspection.

If the direct client determines that equipment is found to be faulty, or a breakdown occurred, he should inform the manufacturer within five working 

days and deliver the equipment to manufacturer. Delivery costs should be covered by customer.

Manufacturer reserves the right to change this technical passport any time without prior notice, if some typographic 

errors or inaccurate information is found, as well as after improving the apps and/or the devices. Such changes will be 

included in the new issues of the technical passport. All illustrations are just for information and thus may differ from the 

original device.

25.1.   LIMITED WARRANTY COUPON

Warranty term

24 months*

I received complete package and technical manual of the product ready for usage. I have read warranty terms and conditions and agree with them: 

 

..........................................................................................................................................................................

Customer’s signature

*refer to WARRANTY CONDITIONS

Dear User, we appreciate your choice and do hereby guarantee that all ventilation equipment manufactured by our Company is inspected and 

thoroughly tested. An operational and high-quality product is sold to the direct buyer and shipped from the territory of the factory. It is provided with 

a 24-month warranty since invoice issue date.

Your opinion is important to us, thus we always look forward to hearing your comments, feedback, or suggestions regarding technical and opera-

tional characteristics of the Products.

In order to avoid any misunderstandings, please read the instructions for installation and operation of the product as well as other technical docu-

ments of the product carefully. The number of the Limited Warranty Coupon and serial number of the product specified on the silver identification 

sticker attached to the housing must match. 

The Limited Warranty Coupon shall be valid provided that the seller’s stamps and records are clear. It is prohibited to change, delete, or rewrite 

the data specified on it in any manner – such a coupon shall be invalid.

With this Limited Warranty Coupon the manufacturer confirms one’s obligations to implement the imperative requirements established by effective 

laws on protection of consumer rights in the event of identification of any defects of the products.

The manufacturer reserves the right to refuse provision of free warranty servicing in cases when the warranty conditions listed below are disre-

garded.

Содержание RIRS EKO 3.0 1900 HE

Страница 1: ...RIRS 1200 5500 H EKO 3 0 EN MOUNTING AND INSTALLATION INSTRUCTION...

Страница 2: ...RS 11 18 2 FAN 11 18 3 HEAT EXCHANGER 12 18 4 ELECTRICAL HEATER 13 19 AUTOMATIC CONTROL 13 19 1 SYSTEM PROTECTION 14 19 2 USING THE UNIT IN BMS NETWORK 14 19 3 MODBUS ADRESSES 15 19 4 ELECTRICAL CONNE...

Страница 3: ...quency Max current Max power consumption Protection class Weight xxx xx VAC Hz x xx A x xx kW IP xx xx kg Made in iauliai Lithuania AHU000000 BN xxxxxx 2019 01 01 SERIAL 2514523357 XXX GAMINIO PAVADIN...

Страница 4: ...da Antifrost system uses dis balancing of the air flow and it may cause negative pressure in premises Great care should be taken when using at the same time in premises as another heating appliance wh...

Страница 5: ...715 3 1 0 715 3 1 1 3 6 4 1 3 6 4 speed min 1 2800 2800 2390 2390 supply power current kW A 0 715 3 1 0 715 3 1 1 31 6 4 1 3 6 4 speed min 1 2800 2800 2390 2390 control input VDC 0 10 0 10 0 10 0 10...

Страница 6: ...r 6 Control board 7 Extract air filters panel pocket 8 Supply air filter panel pocket 9 Rotor engine 7 OPERATING CONDITIONS 5 C o 40 C o 40 C o 40 C o 15 C o 40 C o 3 C o 40 C o 5 C o 40 C o 23 C o 40...

Страница 7: ...he unit first unpack the accessories Remove the film from the unit Remove the bracing packaging tape which keeps the protective profiles Remove the protective profiles After unpacking the unit examine...

Страница 8: ...CE REQUIREMENTS L 1 5xL L 1 5xL H Min distance to open the door 1 5xL Min distance to open control box door H 400 mm 13 MOUNTING The protective film is intended to protect the unit during transportati...

Страница 9: ...CTION OF THE AIR DUCT Figure 14 1 Circular air duct conection Figure 14 2 Rectangular air duct conection 15 CONNECTION DIAGRAM PS PS PS PS PS 2 2 2 2 2 Figure 15 1 RIRS 1200 1900 HE EKO 3 0 Placement...

Страница 10: ...ostat KV2 Water pre heater TV2 Water preheater temperature sensor KV3 Water cooler TV3 Water cooler temperature sensor DX DX cooler U3 PV pressure transmitter M1 By pass damper U4 IV pressure transmit...

Страница 11: ...power connection diagrams all electrical equipment protection elements are properly connected if they are additionally used cables and wires correspond to all applicable safety and functional requirem...

Страница 12: ...cause disbalance of impeller or damage it Hold the fan by the casing Figure 18 1 RIRS 1200 1900 H EKO 3 0 Figure 18 2 RIRS 2500 5500 H EKO 3 0 18 3 HEAT EXCHANGER Be sure the unit is disconnected from...

Страница 13: ...by the ESKM controller using the PWM signal If the water supply air heater is used then the actuator is controlled using RG1 controller with analogous 0 10V DC signal BOOST feature Fans are started a...

Страница 14: ...pes of the capillary thermal protections are used for the overheat protection of the electrical heater manual and automatic Automatic thermal protection is activated when air temperature exceeds 50 C...

Страница 15: ...Supply air temperature sensor alarm 1 a c t i v e o passive 9 RH 01h_Read_Coils 9 1 TJ 100 humidity sensor alarm controller works in deter mining the moisture content of 70 1 a c t i v e o passive 10...

Страница 16: ...should be used Connect the plug RJ10 type to the RS485 1 socket of the unit Connect the other end to the control panel RS458_1 RS458_2 NOTE The remote control panel can be connected and or disconnecte...

Страница 17: ...24VAC G System potential 24VAC 24VAC 3 position M5 G Y2 Y1 Water cooler valve actuator Jumper STOP NO START NC BOOST CE7 7 X16 7 PE N L1 L1 N PE L1 N PE L1 N PE 1f 230V AC Power supply cable X16 36 36...

Страница 18: ...a LED2 Air damper close LED9 Medium fans speed LED2 LED3 Air damper open LED10 Minimal fans speed LED4 Water valve open LED11 Supply air fan speed reducing LED5 Water valve close LED12 Preheater LED6...

Страница 19: ...19 06 20 1 LABELING CHARACTERISTICS OF THE CONTROLLER AND THE SYSTEM COMPONENTS Contact No Labeling Description I O type Max load Min load A mA X10 L 230V 50Hz power supply I X8 N 230V 50Hz power supp...

Страница 20: ...AO X33 5 VAL Cooling valve common Pulse 24v 50hz AO M1 By pass actuator X33 6 DMP Bypass damper opening PWM 24v 50hz AO 100mA X33 7 DMP By Pass damper closing PWM 24v 50hz AO 100mA X33 8 DMP By Pass d...

Страница 21: ...1 2 COM PV Supply air fan X37 1 V1 Supply air fan 0 10V AO X37 2 COM COM IV Extract room s air fan X37 3 V2 Extract air fan 0 10V AO X37 4 COM COM 20 2 REGULAR SYSTEM CHECK UP The operation of the swi...

Страница 22: ...3 2 CHIL X33 9 COM X33 10 BOOST STOP NO START NC A2 A1 R1 8 7 X16 3 ALARM X33 11 COM ANTI F Fan fall 1 2W max 4 5 6 10 9 X16 4 24 1 2W max Fan run 11 12 COM FAN 25 24 23 24V DC 24 intput 0 10V DC 25 G...

Страница 23: ...A1 R1 8 7 X16 3 ALARM X33 11 COM ANTI F Fan fall 1 2W max 4 5 6 10 9 X16 4 24 1 2W max Fan run 11 12 COM FAN 25 24 23 24V DC 24 intput 0 10V DC 25 GND Transmitter 1 24 VDC U P 23 X29 X25 N L 3 1 P DX...

Страница 24: ...230V AC 230V AC ON OFF ON OFF L X37 TL LOW X32 1 COM X32 4 HIGH X32 2 TIMER X32 3 COM X33 1 MIDL X33 2 CHIL X33 9 COM X33 10 BOOST STOP NO START NC A2 A1 R1 8 7 X16 3 ALARM X33 11 COM ANTI F Fan fall...

Страница 25: ...1 FA 13 14 16 15 X16 6 TL LOW X32 1 COM X32 4 HIGH X32 2 TIMER X32 3 COM X33 1 MIDL X33 2 CHIL X33 9 COM X33 10 BOOST STOP NO START NC A2 A1 R1 8 7 X16 3 ALARM X33 11 COM ANTI F Fan fall 1 2W max 4 5...

Страница 26: ...JK 10K TJ tiekiamo oro temperat ros jutiklis TJK 10K TE i metamo oro jutiklis TJK 10K DTJ100 i traukiamo oro temperat ros santykin s oro dr gm s jutiklis keitiklis PV tiekiamo oro ventiliatorius EC IV...

Страница 27: ...S 0K Automatic connection s principal scheme 1 01 2019 06 04 2019 06 04 5 5 110 N L KE2 PE PE1 15 15 1 10 2 9 X21 87 127 Q3 B 16 7 W5 White 14 W5 Red 14 W5 Red AT3 12 R2 A1 A2 11 14 R2 17 17 16 16 87...

Страница 28: ...28 EN RIRS 1200 5500 H EKO 3 0 v2019 06 21 7 RIRS 3500 HW EKO 3 0...

Страница 29: ...s Green alias White balta Yellow Orange geltonas oran inis Blue Black Grey m lynas juodas pilkas Gray pilkas Red raudonas ym jimas Feston PKC Pin MTA2 Jungties lizdas Jungties ki tukas Kabelis su dvie...

Страница 30: ...500HW V2 4 RHX 0k principin schema UAB SALDA Lap M stelis Svoris Lapas Raid Data Para as Dok Nr Lapas Pak Pareng Tikrino Tikrino X42 1 2 3 4 5 7 6 8 9 10 11 12 14 13 15 Spalvinis ym jimas Yellow Green...

Страница 31: ...1 0 White White White White K Grik as TJ Supply air temperature sensor TV 1 4 T1 Water heater antifreeze thermostat Water heater antifreeze return heat carrier temperature sensor Lap M stelis Svoris L...

Страница 32: ...WH BK RD GN BU RG3 TK TK PWM 0 A1 A2 X04 YE WH BK RD 1 2 X22 1 2 1 3x400V B25 X16 10 1 2 F1 6 3A A1 A2 A1 A2 A2 A1 5 6 7 L1 N 9 10 X21 3 C 0 AT3 KE2 50w M3 N 1 L 2 L 3 230V AC N L control X46 N 1 L 2...

Страница 33: ...ition Y2 Y1 VAL VAL VAL X33 3 X33 4 X33 5 3 1 2 X16 1 Y1 Control OPEN AC 24 V Y2 Control CLOSE AC 24 V G System potential AC 24 V X35 2 X35 1 X33 13 X33 14 X33 18 X33 12 X33 17 X33 25 X33 26 X34 1 X34...

Страница 34: ...www salda lt RIRS EKO 3 0 2500 HE 2500 HW 3500 HE 3500 HW 5500 HE 5500 HW Declared typology bidirectional bidirectional bidirectional bidirectional bidirectional bidirectional Type of drive Variable...

Страница 35: ...sk reduction LST EN 60204 1 2006 Safety of machinery Electrical equipment of machines Part 1 General requirements LST EN 60335 1 2012 Household and similar electrical appliances Safety Part 1 General...

Страница 36: ...iver the equipment to manufacturer Delivery costs should be covered by customer Manufacturer reserves the right to change this technical passport any time without prior notice if some typographic erro...

Страница 37: ...37 RIRS 1200 5500 H EKO 3 0 v2019 06...

Страница 38: ...38 RIRS 1200 5500 H EKO 3 0 v2019 06...

Страница 39: ...39 RIRS 1200 5500 H EKO 3 0 v2019 06...

Страница 40: ...NANCE TABLE Product name LOT number Instalation Interval Datum Fan cleaning Once a year Heat exchanger cleaning Once a year Filter replacement Every 3 4 months Look at the product label At least NOTE...

Отзывы: