background image

IMPORTANT: IN THE INTEREST OF PRODUCT PERFORMANCE AND SAFETY PLEASE READ THESE INSTALLATION AND WARRANTY INSTRUCTIONS BEFORE INSTALLING THE PRODUCT.

Nominal frequency (Hz)

Product installation orientation

Operating ambient min/max (°C)

Product application

Operating humidity

Pixie connectivity

Storage ambient limit (°C)

*IP rating

Storage humidity

Attachment type

Horizontal wall mount

50

*IP rating for interior products: The designated IP rating is “from below the ceiling” unless otherwise specified.
IP rating ALL products: Termination of the product must be made in accordance with the IP rating.

Model No.

Input (V)/(Hz)

 

Dimension L x W x H (mm)

MUST BE INSTALLED

BY A LICENSED

ELECTRICIAN

DIY

0 to 40

Interior residential or commercial

10% to 85% RH, NC
0 to 60

20
N/A

10% to 85% RH, NC

Yes

Wireless

Bluetooth Mesh Technology

SMF/BTAS/BP

240/50

N/A

Blue

42 x 24 x 24

SAL National Pty Ltd. 40 Biloela Street Villawood NSW 2163 ABN 21 633 189 474

Copyright SAL V12 FEB 2020   |  

www.sal.net.au

  |  Page 1 of 2

PIXIE SMF/BTAS/BP MULTIFUNCTION CONTROL G3 electrical and installation specification effective 29/7/2020.

SAL products are designed in accordance with all mandatory International and Australian Standards, which require installation 
in accordance with AS/NZS3000 by a qualified installer and regular cleaning and maintenance of the equipment. Products are 
sold in accordance with the following instructions and SAL standard terms and conditions of sale, available via www.sal.net.au.

Due to continued product and information updates, product data sourced from sal.net.au shall not form part of any contract and or technical performance 
guarantee unless expressly confirmed in writing by SAL at the time of order.

General product application requirements (if applicable):

1. CCT and POWER selections (where supplied) – IMPORTANT, where CCT colour temperature or POWER  selection switching is provided, it is important to switch OFF the 

power before the selection is made, otherwise equipment damage may occur.

2. Recycling – SAL encourages recycling, please consider the environment when disposing of packaging, batteries & components.

3. Switching or test intervals – For optimum product performance, good design practice does not encourage 24/7 operation of lighting products without the provision 

of a routine switching or regulatory test cycle. As a guide for continual operation installations, a twelve (12) hour duration for Industrial and Commercial applications 

and a six (6) hour duration for Residential applications should be considered. 

4. Product maintenance – In line with the relevant design standards and to protect your investment, it is important to have in place a routine cleaning program that 

reflects the installation environment and maintains the product in a clean and functional condition. 

IMPORTANT - The supply must be isolated before any product maintenance or cleaning is conducted. In addition, damage to ANY cable or cord supplied with the 

product must be addressed as follows; For attachment type X having a specially prepared cable, if the external flexible cable is damaged, it must be replaced by an 

equivalent cable exclusively available from the manufacturer or authorised installer. For attachment type Y, if the external flexible cable is damaged, it must be 

exclusively replaced by an equivalent cable by the manufacturer or authorised installer. 

For attachment type Z, if the external flexible cable is damaged, the cable cannot be replaced and the luminaire must be destroyed.

5. Adverse, corrosive and coastal installation environments – Unless the product is specifically designated for such applications in these installation instructions, which is 

supported by a professional maintenance program; installation of equipment in such environments is not recommended.

6. Dimming products – Dimming circuits and product compatibility must be validated by the installer before installation; SAL cannot be responsible for third party 

changes in dimmer compatibility.

7. Suspended products – For installation safety, any suspended products must NOT be installed in high air movement spaces or locations subject to impact.

8. Light source replacements – (Non-replaceable light sources) - The light source of the product is deemed not replaceable, when the product reaches its end of life 

the complete product, it must be replaced by a qualified installer. (Non-user replaceable light sources) - The light source of the product must only be replaced by the 

manufacturer or qualified installer. Caution, risk of electric shock.

9. Interior downlights and sensors with remote drivers and electrical accessories  The mounting facilities provided for the device (if any), need only be utilized if in the

application of the product is required by AS/NZS3000. Drivers are not designed for installation environments that restrict conventional airflow.

10. Floodlight products – Unless nominated aiming restrictions or installation parameters apply, products are designed for installation environments between ground and 

15 metres in height, subject to the desired optical performance being achieved.?

11. Emergency enabled products – In the interest of transport and safety, emergency products are supplied with the battery disconnected. In addition to specific 

emergency commissioning instructions, this battery MUST be connected at the time of installation.

12. Specific installation procedures (if any) - this device must be installed by a licensed electrician and is only compatible with SAL PIXIE Smart (master) devices:

Colour

Min / Max loads

Operation instruction:

  

1. Switch off the mains power
2. Terminate conductors, as per the wiring diagram
3. Switch on the mains power
4. Program the product. One can either simply pair it with a PIXIE master 
device to achieve multiway control, or program in PIXIE or PIXIE PLUS app 
control a group or a scene.