background image

Model NO.

Operation Ambience

Temperature (

˚

C)

Output

IP Rating

Storage Ambience 

Temperature (

˚

C)

Storage Humidity

Role in PIXIE System

Attachments

PC100CS/R/BTAM

240V~ 50Hz

0 ~ 40

Wireless signal

IP20

0 ~ 60

10% - 85% RH, NC

10% - 85% RH, NC

Contact sensor (sold separately)

Master

Operation Humidity

Input

SAL products are designed in accordance with all mandatory International and Australian Standards, which require installation in accordance with 

AS/NZS3000 by a qualified installer and regular cleaning and maintenance of the equipment. Products are sold in accordance with the following 

instructions and SAL standard terms and conditions of sale, available via www.sal.net.au.

Due to continued product and information updates, product data sourced from sal.net.au shall not form part of any contract and or technical performance 

guarantee unless expressly confirmed in writing by SAL at the time of order. The product wireframe drawings in this document are intended for illustration purposes 

only and may differ from the final physical product. The installation instruction is subject to change without prior notice.

MASTER

1. Foreword

IMPORTANT: IN THE INTEREST OF PRODUCT PERFORMANCE AND SAFETY PLEASE READ THESE GUIDE AND WARRANTY INSTRUCTIONS BEFORE INSTALLING THE PRODUCT.

2. Product Introduction

PIXIE Contact Sensor Transceiver is a smart device that monitors open & closed 

status of gates/doors/windows, via a set of contact sensors (sold separately). Push 

notification to users are delivered (PIXIE PLUS App only) when status change occurs. 

Any status change can be used as a trigger for logic control within the system to 

deliver more advanced home automation functions, e.g, if the door is open, then 

turn on a PIXIE smart switch.

2.1 Product Features

• Works with wired contact sensors (magnetic reed switches) for gates, doors and 

windows, to monitor open & closed status

• Connect with 1 set of contact sensor equals monitoring of 1 gate or door or 

window status

• In-built button for easy setup and control

• One RGB LED indicator to reflect different working modes and gate/door/win-

dow status

2.2 The package includes

• PIXIE Contact Sensor Transceiver * 1

• Quick Start Guide *1

4. Installation and Wiring

4.1 Preparation

-Select suitable contact sensor (NC type), which comes as a pair, consisting 

of a reed switch and a magnet. The reed switch contact is closed when the 

magnet is present, and the contact opens when the magnet moves away. 
-The reed switch comes with cable attached and is supposed to be mounted 

on a fixed surface, e.g. the ground, the wall, or a pole etc. The magnet is 

supposed to be mounted on a moving part
-Make sure the reed switch contact is closed when the gate/door is closed, 

and the contact is open when the gate/door is open.

4.2 Installation**

1. Mount the contact sensor onto the desired position
2. Wire the PIXIE Contact Sensor Transceiver as per the wiring diagram on the 

right
3. Supply power to the PIXIE Contact Sensor Transceiver, make sure the LED 

indicator is lit and in white colour

2.3 Product illustration*

3. Specifications

DIY

PC100CS/R/BTAM

PIXIE Contact Sensor 

Transceiver 

Quick Start Guide

Version
Date

15/12/2023

1.1

1/2

*All drawings shown are for illustration purpose 

only, actual product may vary due to product 

enhancement.

MASTER

110 mm

26 mm

40 mm

Wiring diagram

Set

Power Input

Contact Sensor

Input

(240V~50Hz)

LED Indicator

Set Button

A

N

A

N

Contact

Sensor

No termination this end

Set

240V~

50Hz

Contact 

sensor

CONTACT SENSOR TRANSCEIVER

PC100CS/R/BTAM