Model NO.
Operation Ambience
Temperature (
˚
C)
Output
IP Rating
Storage Ambience
Temperature (
˚
C)
Storage Humidity
Role in PIXIE System
Attachments
PC100CS/R/BTAM
240V~ 50Hz
0 ~ 40
Wireless signal
IP20
0 ~ 60
10% - 85% RH, NC
10% - 85% RH, NC
Contact sensor (sold separately)
Master
Operation Humidity
Input
SAL products are designed in accordance with all mandatory International and Australian Standards, which require installation in accordance with
AS/NZS3000 by a qualified installer and regular cleaning and maintenance of the equipment. Products are sold in accordance with the following
instructions and SAL standard terms and conditions of sale, available via www.sal.net.au.
Due to continued product and information updates, product data sourced from sal.net.au shall not form part of any contract and or technical performance
guarantee unless expressly confirmed in writing by SAL at the time of order. The product wireframe drawings in this document are intended for illustration purposes
only and may differ from the final physical product. The installation instruction is subject to change without prior notice.
MASTER
1. Foreword
IMPORTANT: IN THE INTEREST OF PRODUCT PERFORMANCE AND SAFETY PLEASE READ THESE GUIDE AND WARRANTY INSTRUCTIONS BEFORE INSTALLING THE PRODUCT.
2. Product Introduction
PIXIE Contact Sensor Transceiver is a smart device that monitors open & closed
status of gates/doors/windows, via a set of contact sensors (sold separately). Push
notification to users are delivered (PIXIE PLUS App only) when status change occurs.
Any status change can be used as a trigger for logic control within the system to
deliver more advanced home automation functions, e.g, if the door is open, then
turn on a PIXIE smart switch.
2.1 Product Features
• Works with wired contact sensors (magnetic reed switches) for gates, doors and
windows, to monitor open & closed status
• Connect with 1 set of contact sensor equals monitoring of 1 gate or door or
window status
• In-built button for easy setup and control
• One RGB LED indicator to reflect different working modes and gate/door/win-
dow status
2.2 The package includes
• PIXIE Contact Sensor Transceiver * 1
• Quick Start Guide *1
4. Installation and Wiring
4.1 Preparation
-Select suitable contact sensor (NC type), which comes as a pair, consisting
of a reed switch and a magnet. The reed switch contact is closed when the
magnet is present, and the contact opens when the magnet moves away.
-The reed switch comes with cable attached and is supposed to be mounted
on a fixed surface, e.g. the ground, the wall, or a pole etc. The magnet is
supposed to be mounted on a moving part
-Make sure the reed switch contact is closed when the gate/door is closed,
and the contact is open when the gate/door is open.
4.2 Installation**
1. Mount the contact sensor onto the desired position
2. Wire the PIXIE Contact Sensor Transceiver as per the wiring diagram on the
right
3. Supply power to the PIXIE Contact Sensor Transceiver, make sure the LED
indicator is lit and in white colour
2.3 Product illustration*
3. Specifications
DIY
PC100CS/R/BTAM
PIXIE Contact Sensor
Transceiver
Quick Start Guide
Version
Date
15/12/2023
1.1
1/2
*All drawings shown are for illustration purpose
only, actual product may vary due to product
enhancement.
MASTER
110 mm
26 mm
40 mm
Wiring diagram
Set
Power Input
Contact Sensor
Input
(240V~50Hz)
LED Indicator
Set Button
A
N
A
N
Contact
Sensor
No termination this end
Set
240V~
50Hz
Contact
sensor
CONTACT SENSOR TRANSCEIVER
PC100CS/R/BTAM