background image

IMPORTANT: IN THE INTEREST OF PRODUCT PERFORMANCE AND SAFETY PLEASE READ THESE INSTALLATION AND WARRANTY INSTRUCTIONS BEFORE INSTALLING THE PRODUCT. 

Operating ambient min/max (°C)

Storage ambient limit (°C)

Operating humidity

Storage humidity

Product application
Product installation orientation
PIXIE connectivity
Termination of the product must be made in accordance with the IP rating. Product IP rating – IP20

MUST BE INSTALLED

BY A LICENSED

ELECTRICIAN

DIY

0 to 40

 0 to 60

10% to 85% RH, NC
Interior residential
As per wiring diagram
Yes

+10% to 85% RH

SAL National Pty Ltd. 40 Biloela Street Villawood NSW 2163 ABN 21 633 189 474

Copyright SAL V12 FEB 2020   |  

www.sal.net.au

  |  Page 1 of 2

PIXIE Blind & Signal Control - PC206BS/R/BTAM electrical and installation specification effective 28/9/2020.

SAL products are designed in accordance with all mandatory International and AS/NZS Standards, which require installation in 
accordance with AS/NZS3000 by a qualified installer and regular cleaning and maintenance of the equipment. Products are 
sold in accordance with the following instructions and SAL standard terms and conditions of sale, available via www.sal.net.au. 

Due to continued product and information updates, product data sourced from sal.net.au shall not form part of any contract and or technical performance 
guarantee unless expressly confirmed in writing by SAL at the time of order.

LED indicator: LED indicator colour is white when the product is new or has been reset; LED indicator colour is blue when product is added to a network; LED indicator 
is low brightness when in standby, and maximum brightness when the relay is closed.

General product application requirements (if applicable):

1. CCT and POWER selections (where supplied) – IMPORTANT, where CCT colour temperature or POWER  selection switching is provided, it is important to switch OFF the 
power before the selection is made, otherwise equipment damage may occur.

2. Recycling – SAL encourages recycling, please consider the environment when disposing of packaging, batteries & components.

3. Switching or test intervals – For optimum product performance, good design practice does not encourage 24/7 operation of lighting products without the provision 
of a routine switching or regulatory test cycle. As a guide for continual operation installations, a twelve (12) hour duration for Industrial and Commercial applications 
and a six (6) hour duration for Residential applications should be considered. 

4. Product maintenance – In line with the relevant design standards and to protect your investment, it is important to have in place a routine cleaning program that 
reflects the installation environment and maintains the product in a clean and functional condition. 

IMPORTANT - The supply must be isolated before any product maintenance or cleaning is conducted. In addition, damage to ANY cable or cord supplied with the 
product must be addressed as follows; For attachment type X having a specially prepared cable, if the external flexible cable is damaged, it must be replaced by an 
equivalent cable exclusively available from the manufacturer or authorised installer. For attachment type Y, if the external flexible cable is damaged, it must be 
exclusively replaced by an equivalent cable by the manufacturer or authorised installer. For attachment type Z, if the external flexible cable is damaged, the cable 
cannot be replaced and the luminaire must be destroyed.

5. Adverse, corrosive and coastal installation environments – Unless the product is specifically designated for such applications in these installation instructions, which is 
supported by a professional maintenance program; installation of equipment in such environments is not recommended.

6. Dimming products – Dimming circuits and product compatibility must be validated by the installer before installation; SAL cannot be responsible for third party 
changes in dimmer compatibility.

7. Suspended products – For installation safety, any suspended products must NOT be installed in high air movement spaces or locations subject to impact.

8. Light source replacements – (Non-replaceable light sources) - The light source of the product is deemed not replaceable, when the product reaches its end of life 
the complete product, it must be replaced by a qualified installer. (Non-user replaceable light sources) - The light source of the product must only be replaced by the 
manufacturer or qualified installer. Caution, risk of electric shock.

9. Interior downlights and sensors with remote drivers and electrical accessories  The mounting facilities provided for the transformer/driver (if any), need only be utilized 
if in the application of the product is required by AS3000. Drivers are not designed for installation environments that restrict conventional airflow.

10. Floodlight products – Unless nominated aiming restrictions or installation parameters apply, products are designed for installation environments between ground and 
15 metres in height, subject to the desired optical performance being achieved.?

11. Emergency enabled products – In the interest of transport and safety, emergency products are supplied with the battery disconnected. In addition to specific 
emergency commissioning instructions, this battery MUST be connected at the time of installation.

12. Specific installation procedures (if any) - this device must be installed by a licensed electrician:

Introduction: This product is designed with two relays to generate two channel dry contact signal outputs, which as an example is ideal for controlling blinds and 

garage door functions.

Model No.

Input (V)/(Hz)

 

Dimensions L x W x H (mm)

PC206BS/R/BTAM

240/50

6A per channel (2 channels)

75 

110 x 40 x 26

Mass (g)

Output Relay Rating

Отзывы: