3 PERIODICAL MAINTENANCE
– 67 –
3.4 Maintenance Procedure
For servicing the engine, see the separate engine manual.
(1) Every 10 hours or daily
⑤
Engine oil level gauge
Shut down the engine and check the engine oil level. If it
is not between MAX and MIN marks, add oil through the
fill hole.
The engine oil level may rise
In engines installed with DPFs, some fuel may become
mixed into the engine oil during cleaning (burning) of the
DPF, diluting (increasing the amount of) the engine oil. If
the level rises above the maximum level on the engine oil
gauge, change the oil immediately as it may cause the
engine to break down.
CAUTION
• When intervals between DPF cleaning become five hours or shorter, it is time to
change the engine oil.
• Be sure to use engine oil recommended by SAKAI (refer to page 84).
⑯
Radiator : Reserve tank
Remove the cap from the radiator to make sure it is filled
to the top with coolant, and top it up if it is not.
Moreover, let the engine idle for 2 to 3 minutes and check
to make sure the coolant in the reserve tank is between
Full and Low. If it is not, remove the reserve tank cap and
top it up with more coolant. Use soft water for the coolant.
WARNING
Do not remove the radiator cap
while the coolant is hot. Before
removing, raise the lever on
the cap to release the internal
pressure.
IMPORTANT
Change the cooling water every two years.
Содержание SV204 Series
Страница 2: ......
Страница 6: ......
Страница 29: ...1 BASIC PRECAUTIONS FOR SAFETY 23 WARNING Negligence of these instructions can lead to accidents ...
Страница 70: ...3 PERIODICAL MAINTENANCE 64 3 3 Periodical Maintenance Points 1 SV204D SV204T SV204TF ...
Страница 71: ...3 PERIODICAL MAINTENANCE 65 2 SV204TB ...
Страница 89: ...3 PERIODICAL MAINTENANCE 83 ...
Страница 98: ......
Страница 100: ......