5.3.4 During off-network operation time, null line at the BACK-UP end
will remain to be connected with the null line at the power grid end
inside the machine. (Only applicable to market in Australia)
5.4 PV Connection
Cable Cross-sectional area
(
mm²
)
External diameter
(
mm
)
Range
Recommend
Range
Recommend
4.0~6.0
4.0
4.2~5.3
5.3
Table5.3 Recommended Specifications of DC Cables
DC connector is made up of the positive connector and the negative
connector
1. Insulated Enclosure 2. Lock Screw 3. Positive Connector
Figure 5.5 Positive Connector
1. Insulated Enclosure 2. Lock Screw 3. Negative Connector
Figure 5.6 Negative Connector
NOTICE
· Please place the connector separately after unpacking in order to avoid confusion for
connection of cables.
· Please connect the positive connector to the positive side of the solar panels, and