PFD2/PFS2 – OPERATING INSTRUCTIONS
INDEX
DATE
N°
03
26/06/01
DC02020US
11/11
VI.3.4 – Replacing the PTFE sleeves
Follow the same procedure as for VI.3.3 and VI.3.4 until 14); after replacing the composite rings,
remove the PTFE sleeves (P/N 7220) from the groove with a blunt pointed instrument. Clean and re-
assemble the new part.
NB
: PTFE sleeves are only compatible with pumps of series 3. A pump that was not originally fitted
with PTFE sleeves can be equipped with sleeves. In this case, you need to change the plates
(P/N 2741 and 2746).
VI.3.5 – Replacing the bellow and body O.rings
After removing the bellows (see V1.3.2, step 8), remove the bellow Viton O.rings (P/N 2724) and the
body O.rings (P/N 2738 or 2588). Then carefully replace the new ones
without scratching the
surface of the bellow (P/N 2760 or 2760S) or housing (P/N 2748 or 2748G).
VI.3.6 – Replacing the manifold O.rings
Follow point VI.3.2 steps 3) and 4). Carefully replace the manifold O.rings (P/N 2464). Take care as
these parts are fragile,
especially the elbow connectors.
If your pump is marked with "
W
", change the manifold seals (P/N 2587) and retighten progressively
with a strap wrench.
NB
: This chapter does not concern PFD/S2…
G
pumps that have no manifold seals.
VI.3.7 – Replacing other parts
When dismantling the pump or control unit for service, components found damaged should
be replaced. Alternatively, the pump/control unit can be returned to your distributor or SGPPL
ASTI for examination, estimate, and repair.
Important
: Please indicate what chemical was handled, the frequency of use, and the reason for
returning the pump.
A receipt note "Conditions of use" is at your disposal. Do not hesitate to ask for it when needed.
An estimate for repair will be proposed to you and the pump will be returned to you within one week
from date of its acceptance.
VII – Warranty
SGPPL ASTI pumps and accessories are warranted for all parts and labor against faulty workmanship
(return to factory) for one year from delivery date (9000 hours of use).
SGPPL ASTI is not responsible for damage to its products through improper installation,
maintenance, use or attempts to operate them beyond their mechanical capacity, intentionally or
otherwise, or for unauthorized repair.
SGPPL ASTI shall not be liable for any indirect, special, incidental or consequential damages
resulting from the use, failure or malfunction of any product.
® Teflon and Kalrez Du Pont's registered trademarks
™ AstiPure Saint-Gobain Performance Plastics Asti trademark