Alarms and notifications
If an alarm is reported from the SAILOR 6390 Navtex Receiver a flashing red triangle
appears in the bottom bar of the SAILOR 6004 Control Panel display:
• Flashing, bright red triangle: Unacknowledged alarm(s).
• Faded red triangle: Acknowledged alarm(s).
To acknowledge an alarm do as follows:
1. Tap the flashing, bright red triangle to display the list with active alarms.
2. Tap the alarm to acknowledge the alarm.
When all active alarms are acknowledged the bright red triangle turns into a faded red
triangle.
Alarms and notifications are either shown in the display of the SAILOR 6004 Control Panel
or output via NMEA sentences and displayed in other equipment.
5.2.1
Installation with SAILOR 6004 Control Panel
Figure 5-5: Viewing alarms
Flashing,
bright
red
Faded
red
Alarm Description
Remedy
001
Navigational Warning
Read associated message.
002
Meteorological Warning
Read associated message.
003
Search and Rescue
Information
Read associated message.
004
Receiver Malfunction
Contact your supplier.
005
Built-in Self Test Failure
Check antenna installation.
006
General Failure
Power cycle the unit. If this does
not help, contact your suplier.
067
GNSS position lost
Check the GPS input.
068
Automatic mode disabled
(no fix)
Check the GPS input. Without a
valid GPS input the automatic
mode does not work.
Table 5-1: Navtex alarms