Appendix C: Grounding and RF protection
TT-98-129218-A
Alternative grounding for steel hulls
61
Terminal grounded at a dedicated RF ground (alternative)
In this case the antenna is grounded with a separate ground cable. The ground cable must be
routed parallel and close to the shielded coax cable connecting the antenna to the terminal
grounding kit. A tinned heavy gauge wire (min. 6 mm2) can be used for this purpose - see
page 64.
Note
The antenna must be electrically isolated at its mounting bolts by means of shoulder
bushes and washers ensuring the isolated RF ground - see page 67.
Antenna grounded
with separate cable
Antenna
Mast
(electrically bonded
to the steel hull)
Base Plate
(Antenna isolated
from the the hull)
Antenna grounded
with mounting bolts
Antenna
Mast
(electrically bonded
to the steel hull)
Base Plate
(electrically bonded to
the hull though the mast)
Recommended
Alternative