Chapter 2: Installing the system
TT-98-129218-A
Placing the terminal
15
Placing the terminal
Where to place the terminal
Temperature conditions
The terminal must be placed in a ventilated area with free space around all sides of the unit,
except the bottom side.
Ambient temperature range is –25°C to +55°C.
If the terminal is installed in a location where the ambient temperature may exceed 50°C, we
recommend placing the terminal where unintentional contact is avoided. If the maximum ambient
temperature does not exceed 50°C, the terminal can be placed in a public area.
Grounding access
The terminal is designed with a cabinet for bulkhead or desktop installation.
The cabinet is equipped with mounting brackets, making it possible to secure the unit on a
bulkhead.
Important
The terminal must be placed in an area where access to the hull or equivalent
grounding can be reached within 0.5 m.