Separate ground cable
98-136280-B
Appendix B: Grounding and RF protection
B-9
BBBB
Gr
ounding and RF
B.6
Separate ground cable
B.6.1
Ground cable - construction
When dealing with electrical installations in a marine environment, all wiring must be
done with double insulated, tinned strands, high quality and if exposed also UV
resistant cables. This shall also apply to the separate ground cable mentioned in the
previous paragraphs.
The ground cable is constructed using an appropriate cable with a cross section area of
at least 6 mm
2
(AWG10) and terminated with insulated ring crimp terminals – see
illustration below. The crimp terminals must be a marine approved type e.g. the
DuraSeal series from Raychem.
Figure B-6: Separate ground cable
$QWHQQD
0,QVXODWHG5LQJ7HUPLQDO
5D\FKHP'XUD6HDO6HULHV
7HUPLQDO
$SSURSULDWHVL]H
,QVXODWHG5LQJ7HUPLQDO
5D\FKHP'XUD6HDO6HULHV
SAILOR100IM.book Page 9 Friday, January 18, 2013 10:28 AM
Содержание 100
Страница 1: ...INSTALLATION MANUAL SAILOR 100 Satellite TV ...
Страница 2: ......
Страница 8: ...vi 98 136280 B SAILOR100IM book Page vi Friday January 18 2013 10 28 AM ...
Страница 140: ...Troubleshooting 8 14 Chapter 8 Service 98 136280 B SAILOR100IM book Page 14 Friday January 18 2013 10 28 AM ...
Страница 141: ...Appendices SAILOR100IM book Page 1 Friday January 18 2013 10 28 AM ...
Страница 142: ...SAILOR100IM book Page 2 Friday January 18 2013 10 28 AM ...
Страница 174: ...List of ACU events C 10 Appendix C System messages 98 136280 B SAILOR100IM book Page 10 Friday January 18 2013 10 28 AM ...
Страница 178: ...Glossary Glossary 4 98 136280 B SAILOR100IM book Page 4 Friday January 18 2013 10 28 AM ...
Страница 185: ......
Страница 186: ...info thrane com thrane com 98 136280 B ...