Operating instructions Concept PDG 2906 peristaltic dosing pump
31 / 44
Factory settings
Designation
Value/setting
Detergent
Delay predosing time
0 sec
Predosing time
0 sec
Conductivity input 0
12.0 mS/cm
Conductivity input 1
1.0 mS/cm
Conductivity input 2
1.0 mS/cm
1)
Dosing alarm time
Automatic
Dosing alarm time (manual mode)
1 min
Rinse-aid
1)
Rinse-aid dosing
Constant
Constant dosing
100 ml/h
Variable dosing
1 ml/litre (fresh water)
1)
Rinse-aid correction factor
1.00
Suction lance
1)
Empty signal delay
0 ml/litre
Code number
Code number 1
0000
1)
Code number 2
(Code number for
changing code numbers 1 and 2)
0000
Other
settings
1)
Language
German
1)
PC access
On
1)
Additive pump
Off
Time
Winter time (
)
1)
Can be set in the “Configuration” menu
Calculate correction factor
Due to the quantities involved, it is essential to use the dosing pump tube PS 138-1.6x1.6-Ri4.
Due to the tube tolerances, the quantity must be corrected with a correction factor. This can be
entered in the “Configuration” menu section.
Calibration is carried out as follows:
-
Set correction factor to 1.00 (“Configuration” menu section).
-
Measure rinse-aid pump volumetrically.
-
Divide the measured value in ml/h by the displayed value in ml/h.
-
Round the result to two decimal places and enter that value as the correction value.