Configuration
ZDUE-LTE-PLUS-VII
Page 33 of 62
7
Configuration
7.1 Parameter
In meter mode, the ZDUE-LTE-PLUS-VII works independently of an external
control, i.e. it independently establishes operational readiness and the
connection to the head end system after applying the supply voltage.
For this, it is necessary that function and communication parameters are
configured beforehand.
The configuration is done via configurable parameters, which are grouped in
several parameter classes.
Overview parameter
class
Before the ZDUE-LTE-PLUS-VII can be used, it must be parameterised.
This is done via the following parameter class:
Class 79 - General operating parameters
Parameter class for configuring identifiers (IDs) of the ZDUE, passwords for
the EN 62056-21 protocol, basic settings for the meter and mobile radio
interface and the automatic periodic reset (watchdog).
Classes 60/61 - Mains parameters
Parameter class for configuring the access data to the mobile network, e.g.
APN, username, password, etc.
Class 82 - IP server parameters
Parameter class for configuring the IP server mode, e.g. IP address, port,
access protection.
Attention:
In order for the ZDUE-LTE-PLUS-VII to work in IP server mode, the
parameter "String length IP destination address / host name" in parameter
class 70 must be set to "00".
When parameterising with parameterisation software that sets the string
length automatically (such as the
ZDUEParametrierTool
), this is achieved
by completely deleting the IP address of the primary IPT master.
Classes 70/76 - IPT parameters
Parameter classes to configure the IP telemetry mode, e.g. addresses and
port of the IPT master, login names, etc.
Attention:
In order for the ZDUE-LTE-PLUS-VII to work in IP telemetry mode, the
parameter "String length IP destination address / host name" in parameter
class 70 must
not
be set to "00".
When parameterising with a parameterisation software that sets the string
length automatically (such as the
ZDUEParametrierTool
), this is achieved
by writing the IP address of the primary IPT master into the ZDUE