90
Unless stated otherwise all dimensions are in mm
Assembly
Zone 1
Zone 4
Zone 3
Zone 2
Temporary
support
used for
frame / unit
assembly.
Safescreen
unit outline
Workstation for
platform assembly &
plywood cut.
Storage area
6.2 Tools
Required tools for the assembly / disassembling of SAFESCREEN
®
units:
•
Spanners *;
•
Ratchet Spanners * (preferably with keyed ends for guidance when aligning holes);
•
Impact drivers * - compressor to suit (consider cordless drivers, however note a
number of battery packs will be required);
•
Sockets sets * (short to long);
•
* Spanner / socket sizes:
24 mm is required for M16 bolts;
19 mm is required for M12 bolts;
5.5 is required for self tapping screws
•
Hammer drill with a set of drill bits;
•
Hammer;
•
Hand saw;
•
Circular saw;
•
Wood sealant and brushes;
•
Measuring tapes
•
Level;
•
Waterproof marker pens;
• Buckets (colour coded for the different fixings to allow easy identification);
• Steel trestles (min. height:0.75 m, safe working load:750 kg each), 12no. approx.;
•
Timber bearers.