background image

MorphoSmart™ Fingerprint scanners Installation Guide 
Secure 

MorphoSmart™ getting started 

 

 

 

 

 

SSE-0000080361-05 
May 2015 

This  document  and  the  information  therein  are  the  property  of  Morpho.  They  must  not  be 
copied or communicated to a third party without the prior  authorization of Morpho 

38 

 

 

13. 

Secure MorphoSmart™ getting started 

13.1  Description 

In  addition  to  normal  installation  process,  the  secure  MorphoSmart™  device  must  be 
unlocked  and  personalized.  To  perform  this,  the  security information  provided  with the 
batch of secure MorphoSmart™ devices  is required: two transport files (usually send by 
email), and their corresponding password (usually send under secure cover). 

 

13.2  Installation 

 

 

 

 

 

 

 

Figure 18: MorphoSmart™ S unlocking with KMS application 

Insert the 

MKMS

 CD into your CDROM drive. If installation does not start automatically, 

run setup.exe from the root directory of the CD. 

After installation, start the DAO 3.6 driver installation from the PROGRAMS folders: 

START / PROGRAMS / MorphoSmartKeyManagementSystem / InstallDAO 3.6 /. 

After installation, start the 

MKMS application

 from the PROGRAMS folders: 

START / PROGRAMS / MorphoSmartKeyManagementSystem / Exe / 

Select  the  '

Root  key  generation

'  action  in  the  '

Initialization

'  menu,  to  create  your 

MorphoSmart™ Certification Authority. 

Click ‘

Insert Transport Files

’ button to import the two transport files and their passwords 

into the 

MKMS 

database (figure 1). 

Set  up  the  value  of  the 

security  configuration  parameters

  and  of  the 

key  parameters

 

('

Initialization

' menu). 

Then connect a new MorphoSmart™ device to the PC, and use the '

MSO Personalization

button to unlock it, and to put it in operational condition.  

Perform the previous action for each new secure MorphoSmart™ device of the batch.  

13.3  Reference 

For  more  information  about  the  secure  MorphoSmart™,  please  refer  to  the 

MorphoSmartKeyManagementSystem.pdf

 file from the PROGRAMS folders: 

START / PROGRAMS / MORPHOSMART

™KeyManagementSystem /Documentation / 

 

MorphoSmart™ Key 
Management System 
(MSO KMS) 

 

 

 

MSO # 1 

Transport 

file # 2 

 

Transport 

file # 1 

 

MSO # 2 

MSO # i 

MSO # n 

Key # 1 
 

Key # 2 
 

Содержание MorphoSmart MSO300

Страница 1: ...MorphoSmart Fingerprint scanners Installation Guide May 2015 SSE 0000080361 05 Version 2 17 MSO300 MSO301 MSO350 MSO351 MSO1300 MSO1350 MorphoSmart Fingerprint scanners Installation Guide ...

Страница 2: ...r any purpose without the express written permission of Morpho The software described in this document is supplied under a license agreement or nondisclosure agreement It is against the law to copy the software on any medium except as specifically allowed in the agreement This manual makes reference to names and products that are trademarks of their respective owners PROPRIETARY RIGHTS This docume...

Страница 3: ... 8 July 2004 Add MMI description for MSO350 Add IDENTLITE license reference 1 9 December 2004 Precisions with the LEDS states Add MSO CBM 2 0 April 2005 Update of hotline phone number 2 1 July 2005 Added the MSO xx1 products reference 2 2 September 2005 Add the SAGEM MorphoSmart Service Provider Usb Server installation in the USB driver installation for MSO3xx and CBM 2 3 January 2006 Added instal...

Страница 4: ...ty without the prior authorization of Morpho 4 2 11 July 2010 Update company name to Morpho 2 12 April 2011 Add MSO1200 device 2 13 May 2011 Font change 2 14 June 2012 Update hotline mail address New order in section Recommendations New recommendation Cable bend radius 2 15 March 2013 Update registered office address 2 16 October 2013 Update MSO1300 and MSO1350 pictures from 2014 2 17 May 2015 Upd...

Страница 5: ...MorphoSmart USB driver setup 15 3 2 Important Notice Administrator rights 15 3 3 Windows XP Embedded 15 3 4 Note for administrators 16 3 4 1 User profile 16 3 4 2 Driver installation files 16 3 4 3 Setup exe file 16 3 4 4 Sagem MorphoSmart USB Drivers msi 16 3 4 5 USB driver deployment through a LAN 16 3 4 6 USB driver installation within a higher level software installation 17 4 Finger Placement ...

Страница 6: ...0 11 1 4 USB connection All USB MorphoSmart devices 31 11 1 5 RS232 connection MSO20x and MSO1200 31 11 1 6 MorphoSmart terminals with Smart Card readers 31 11 1 7 Power Supply 31 11 2 Biometric characteristics 32 11 2 1 Database size 32 11 2 2 Database fulfill time 32 11 2 3 Verify performances 32 11 2 4 Identify performances 33 12 Man Machine Interface 34 12 1 MSO2xx MSO3xx Man Machine Interface...

Страница 7: ...without the prior authorization of Morpho 7 14 7 Cleaning precautions 40 15 FCC Standard 41 16 Bibliography 42 16 1 General information about MSO product family 42 16 2 Integration of MorphoSmart EOM modules 42 16 3 Installation of MorphoSmart desktop terminals 42 16 4 ILV Protocol description of low levels commands 42 16 5 MorphoSmart SDK 42 17 Contacts 43 17 1 Customer service 43 17 2 Hotline an...

Страница 8: ... 5 MorphoSmart MSO300 3D View 21 Figure 6 MorphoSmart MSO350 3D View 21 Figure 7 MorphoSmart MSO3xx Top View 22 Figure 8 MorphoSmart MSO3xx Bottom View 22 Figure 9 MorphoSmart MSO1300 from 2014 24 Figure 10 MorphoSmart MSO1300 3D view 24 Figure 11 MorphoSmart MSO1300 Bottom view 25 Figure 12 MorphoSmart MSO1200 26 Figure 13 MorphoSmart MSO1200 3D view 26 Figure 14 MorphoSmart MSO1200 Bottom view 2...

Страница 9: ...1 MorphoSmart devices weight and sizes 30 Table 2 MorphoSmart devices temperature and humidity range 30 Table 3 MorphoSmart devices IP rating 30 Table 4 Database size 32 Table 5 Database fulfill time 32 Table 6 Identify performances 33 Table 7 MSO20x MSO3xx status 34 Table 8 MSO20x MSO3xx biometric process status 35 Table 9 MSO35x smart card request status 35 Table 10 MSO13x0 system status 36 Tabl...

Страница 10: ...ral The MorphoSmart terminal offers the following advantages high quality optical scanner software development suite MorphoSmart SDK for all MorphoSmart devices Key Management System MorphoSmart KMS for Secure MorphoSmart terminal False Finger detection only available with MorphoSmart MSOxx1 PC SC Smart Card Reader only available with MorphoSmart MSO35x and MSO1350 compact size for easy installati...

Страница 11: ...t be placed on a flat clear surface where it will not be at risk of coming in contact with fluids 2 2 MorphoSmart Hardware Platform Compatibility The MorphoSmart USB devices are compatible with usual PC configurations but we therefore strongly advise you to perform a compatibility test with target PC hardware configuration The MorphoSmart USB devices are compatible with most of the self powered US...

Страница 12: ... supply to an outlet Then connect the RS232 connector to one of the RS232 port of the PC Then the device is ready for use for example with the sample applications delivered with MorphoSmart SDK please refer to MorphoSmart SDK section 2 3 3 MorphoSmart SDK The MorphoSmart Software Development Kit provides the required elements to enable you to develop your own applications for MorphoSmart devices I...

Страница 13: ...May 2015 This document and the information therein are the property of Morpho They must not be copied or communicated to a third party without the prior authorization of Morpho 13 For more information on the MorphoSmart Software Development Kit please refer to the MorphoSmart SDK Programmer Guide document ...

Страница 14: ...this protocol with C language source files is provided with the MorphoSmart SDK package MSO ILV_Sample project 2 4 2 USB connection A MorphoSmart USB device can be physically connected to other host than Windows PC but the MorphoSmart communication protocol over USB and a compatible USB driver must be developed for the host system The integrated USB driver of the MorphoSmart terminal emulates a RS...

Страница 15: ...hts MorphoSmart USB devices are currently compatible with Windows 2000 SP4 Windows XP Professional Edition SP3 and Windows Server 2003 Enterprise Administrator rights on your local computer are required when plugging the MorphoSmart USB device for the first time 3 3 Windows XP Embedded If you are using Windows XP Embedded the automatic installer based on MSI won t work since MSI is not installed o...

Страница 16: ...f the Setup exe file is to install if not already installed the required version of the Microsoft Installer engine MsiEngine Then the Setup exe file is useless if the latest version of the MSIEngine is already installed on the PC 3 4 4 Sagem MorphoSmart USB Drivers msi The msi file can be executed directly by the command line below MsiExec package Sagem MorpoSmart USB Drivers msi The MsiExec exe s...

Страница 17: ...lation within a higher level software installation When only individual installation is required it is possible to include the msi and the cab files in a higher level software installer The typical use of this kind of installer is to install one or several software applications documentation set and the USB driver The execution of the higher level installer should copy these two files msi and cab ...

Страница 18: ...imally positioned Common non optimal finger positioning is illustrated below followed by an illustration of best finger placement Fingerprint Placement Fingerprint Orientation Fingerprint Inclination Fingerprint Rotation Figure 1 Finger placement recommendations Other recommendations for acquiring a quality finger image Fingers should neither be too moist nor extremely dry Exert firm but not exces...

Страница 19: ...ugging your MSO20x into a power source check that the power source to which you intend to connect it complies with the voltage current and frequency specifications on the rating label of the power supply unit depending on model Only use the power supply unit provided with your MorphoSmart terminal Do not use any other power supply The device does not have an on off switch and can only be powered o...

Страница 20: ...o They must not be copied or communicated to a third party without the prior authorization of Morpho 20 5 3 General Description 5 3 1 Top view Figure 3 MorphoSmart MSO20x top view 5 3 2 Bottom view Figure 4 MorphoSmart MSO20x bottom view DB9 RS232 Connector Sensor Upper LED Lower LED Power connector Stand Product sticker Module process Metallic housing Void sticker ...

Страница 21: ...rpho They must not be copied or communicated to a third party without the prior authorization of Morpho 21 6 MorphoSmart MSO3xx 6 1 Physical Characteristics The MSO3xx is dedicated to be connected to an USB port which supplies the required power The MSO35x device includes a smart card reader Figure 5 MorphoSmart MSO300 3D View Figure 6 MorphoSmart MSO350 3D View ...

Страница 22: ...orpho They must not be copied or communicated to a third party without the prior authorization of Morpho 22 6 2 General description 6 2 1 Top view Figure 7 MorphoSmart MSO3xx Top View 6 2 2 Bottom view Figure 8 MorphoSmart MSO3xx Bottom View USB Connector Sensor Upper LED Lower LED Optional Smart Card slot Stand Product sticker Biometric Module Metallic housing ...

Страница 23: ...ant warning The MSOxx1 must be connected to the ground to avoid erratic behavior 7 2 2 MSO3x1 plugged though USB Hub The USB hub must provide a continuous ground between the input socket and the output socket 7 3 Specific Cleaning Precautions It is recommended to clean the sensor when it is dirty Dust lowers the MSOxx1 performances The cleaning material for sensor must be a soft material to preven...

Страница 24: ...t not be copied or communicated to a third party without the prior authorization of Morpho 24 8 MorphoSmart MSO1300 8 1 Physical Characteristics The MSO1300 device is dedicated to be connected to an USB port which supplies the required power Figure 9 MorphoSmart MSO1300 from 2014 8 2 General description 8 2 1 3D view Figure 10 MorphoSmart MSO1300 3D view Sensor USB connector ...

Страница 25: ...0361 05 May 2015 This document and the information therein are the property of Morpho They must not be copied or communicated to a third party without the prior authorization of Morpho 25 8 2 2 Bottom view Figure 11 MorphoSmart MSO1300 Bottom view Stand Plastic housing USB connector ...

Страница 26: ... device is dedicated to be connected to a RS232 port through an electrical interface which supplies the required power and electrical level conversion Figure 12 MorphoSmart MSO1200 Warning the MSO1200 electrical levels are TTL open collector and are not compliant with V 24 recommendation Electrical adapter is mandatory A sample of electric interface is provided in MorphoSmart CBM Module Integratio...

Страница 27: ...0361 05 May 2015 This document and the information therein are the property of Morpho They must not be copied or communicated to a third party without the prior authorization of Morpho 27 9 2 2 Bottom view Figure 14 MorphoSmart MSO1200 Bottom view Plastic housing RJ12 connector Stand ...

Страница 28: ...re the property of Morpho They must not be copied or communicated to a third party without the prior authorization of Morpho 28 10 MorphoSmart MSO1350 10 1 Physical Characteristics The MSO1350 includes a smart card reader and is dedicated to be connected to an USB port which supplies the required power Figure 15 MorphoSmart MSO1350 from 2014 ...

Страница 29: ...rpho They must not be copied or communicated to a third party without the prior authorization of Morpho 29 10 2 General description 10 2 1 Top view and Side view Figure 16 MorphoSmart MSO1350 top view and side view 10 2 2 Bottom view Figure 17 MorphoSmart MSO1350 bottom view USB connector Smart Card Slot Sensor Plastic casing USB cable Product sticker Rubber feet ...

Страница 30: ... pixels Table 1 MorphoSmart devices weight and sizes The weight doesn t include the cord 11 1 2 Temperature range and humidity Device Temperature range Humidity Operating Storage Operating Storage MSO1300 MSO1200 MSO1350 0 C to 50 C 20 C to 70 C 10 RH 85 RH 95 MSO20x MSO3xx 0 C to 50 C 20 C to 70 C 10 RH 80 non condensing RH 95 Table 2 MorphoSmart devices temperature and humidity range 11 1 3 IP r...

Страница 31: ...20x MSO1200 Electrical level V 24 compliant TTL open collector Data rate From 9 600 bps to 115 200 bps Data flow control Software handshake Pin connected Transmitted Data TxD Received Data RxD Common ground GND 11 1 6 MorphoSmart terminals with Smart Card readers MSO35x and MSO1350 devices are equipped with a smartcard reader which complies with ISO 7816 1 4 PC SC protocol CCID over USB protocol W...

Страница 32: ... Interface Specification documentation Number of records 100 500 1000 2000 3000 4000 5000 USB 1 5 s 7 s 15 s 30 s 45 s 60 s 80 s RS232 at 115200 Bd 20 s 1 mn 2 mn 4 mn 6 mn 8 mn 10 mn Table 5 Database fulfill time 11 2 3 Verify performances The verify process compare the search fingerprint to one or more reference fingerprints less than 1 second typical time Please not that the measure starts with...

Страница 33: ...f the user s record It also means that the time required to reject a fingerprint No Hit is higher than the time required to match with the 1st fingerprint of a record Number of records Hit fingerprint 1 Hit fingerprint 2 No Hit 100 1 s 1 5 s 1 5 s 500 1 1 s 1 5 s 1 5 s 2000 1 5 s 2 s 2 s 3000 2 s 2 5 s 2 5 s 5000 2 5 s 3 s 3 s Table 6 Identify performances Please not that The measure starts with f...

Страница 34: ...tables below describe the meaning of the light signals 12 1 2 Biometric terminal status Status Sensor Lower LED Upper LED Suspend low power mode Off Off Off Stand By wait for a request Off Flashing Green See Table Maintenance State such as firmware update in progress Off Blinking Red Blinking Red Personalization State secure MSO Off Blinking Red Blinking Red Unrecoverable Error or USB enumeration ...

Страница 35: ...erty of Morpho They must not be copied or communicated to a third party without the prior authorization of Morpho 35 Table 8 MSO20x MSO3xx biometric process status 12 1 4 Smart card reader status Status Upper LED Smart Card powered on Green Smart Card powered off Off Smart Card treatment in progress Blinking Green Table 9 MSO35x smart card request status ...

Страница 36: ...Machine Interface is reduced to the sensor light on off 12 2 2 Biometric terminal status Status Sensor Suspend low power mode Off Stand By wait for a request from host system Off Maintenance State such as firmware update in progress Blinking Personalization State secure MSO Blinking Unrecoverable Error or USB enumeration Error Off Table 10 MSO13x0 system status 12 2 3 Biometric request status Stat...

Страница 37: ...erein are the property of Morpho They must not be copied or communicated to a third party without the prior authorization of Morpho 37 12 2 4 Smart card reader status MSO1350 Status Sensor Smart Card powered on One blink Smart Card powered off No signal Smart Card treatment in progress No signal Table 12 MSO1350 smart card request status ...

Страница 38: ...ver installation from the PROGRAMS folders START PROGRAMS MorphoSmartKeyManagementSystem InstallDAO 3 6 After installation start the MKMS application from the PROGRAMS folders START PROGRAMS MorphoSmartKeyManagementSystem Exe Select the Root key generation action in the Initialization menu to create your MorphoSmart Certification Authority Click Insert Transport Files button to import the two tran...

Страница 39: ...n the cable need to be bended please to figure below it is recommends to have a bend radius value higher than 1 2 cm Figure 19 MorphoSmart cable radius recommendation 14 3 Areas containing combustibles It is strongly recommended that you do not install your MorphoSmart terminal in the vicinity of gas stations petroleum processing facilities or any other facility containing flammable or combustible...

Страница 40: ...ccessories will void your warranty 14 6 Environment conditions Do not use your MorphoSmart terminal in damp areas ex swimming pools etc It must be protected from water and other liquids Do not expose your MorphoSmart terminal to extreme temperatures Do not expose your terminal to direct sunlight Due to electrostatic discharge and depending on the environment synthetic carpet should be avoided in a...

Страница 41: ...has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interferenc...

Страница 42: ...eral information about MSO product family MorphoSmart Overview ref SSE 0000080368 16 2 Integration of MorphoSmart EOM modules MorphoSmart module Integration ref SSE 0000080364 MorphoSmart CBM module integration ref SSE 0000077475 16 3 Installation of MorphoSmart desktop terminals MorphoSmart Installation ref SSE 0000080361 16 4 ILV Protocol description of low levels commands MorphoSmart Host Syste...

Страница 43: ...ts 17 1 Customer service Morpho SAV Terminaux Biométriques Boulevard Lénine BP428 76805 Saint Etienne du Rouvray FRANCE Phone 33 2 35 64 53 52 17 2 Hotline and Customer assistance Morpho Support Terminaux Biométriques 18 Chaussée Jules César 95520 OSNY FRANCE hotline biometrics morpho com Phone 33 1 58 11 39 19 9H00am to 6H00pm French Time Monday to Friday http www biometric terminals com Login an...

Страница 44: ...Copyright 2015 Morpho Registered Office 11 boulevard Gallieni 92130 Issy les Moulineaux France www morpho com ...

Отзывы: