MorphoAccess® SIGMA Series - Administrator Guide
Compatibility with an Access Control System
2017_2000025464-v03
This document and the information therein are the property of Morpho. They must not
be copied or communicated to a third party without the prior authorization of Morpho
468
July 17
Activation key
A specific configuration key enables this feature.
Parameter name
Value
Description
gpio.sdac_rte_mode
0, 1
The administrator can set an exit mode in SDAC,
by using this parameter. Following values can
be configured:
Parameter value “0” means None
Parameter value “1” means Push
Button. Push button exit mode is
selected when a push button is located
at exit gate and users are allowed to
push the exit button to open the exit
door.
Configuration key
Parameter name
Value
Description
gpio.sdac_rte_egress_timeout 1 to 300
Seconds
(25–
Default)
The administrator can define an egress
timeout, by using this parameter. The ‘egress
timeout’ is defined as the duration for which
terminal will not generate an alarm, if door is
opened by using a push button, manual or
forced method of opening. No user control is
performed within this duration. The door closes
automatically, once the ‘egress timeout’ period
elapses.
For this to work
gpio.sdac_rte_mode should be either set to 1
or 2
gpio.func_mode must be set to SDAC mode