MorphoAccess® SIGMA Series - Administrator Guide
2017_2000025464-v03
This document and the information therein are the property of Morpho. They must not
be copied or communicated to a third party without the prior authorization of Morpho
453
July 17
Presentation of Proxy (or slave) mode
Process
The administrator can configure the MorphoAccess® SIGMA Family terminal in the proxy mode.
This operating mode allows controlling the MorphoAccess® SIGMA Family terminal remotely via
IP link or RS422 (Applicable to MorphoAccess® SIGMA Series only). This is achieved by using a
set of biometric and databases management commands.
In Proxy mode the Host System plays the master. It performs access control remotely, while the
MorphoAccess® SIGMA Family terminal works as a slave waiting for external commands. These
commands are enlisted as follows.
user identification,
user verification,
relay activation,
read data on a contactless smart card,
Biometric database management,
terminal configuration changes,
read an entry from the keyboard,
display a message,
read a contactless smart card.
The MorphoAccess® SIGMA Family terminal is driven through an Ethernet (or Wi-Fi™) link using
TCP or SSL protocol.
The terminal acts as a server: it is either waiting for a command or executing a command.
Please refer to MorphoAccess® 5G Series – Host System Interface Specifications: this
document explains how to remotely manage a terminal.
For further details about SSL on the MorphoAccess® SIGMA Family terminal, please refer to the
SSL Solution for MorphoAccess® documentation.