MorphoAccess® SIGMA Series - Administrator Guide
2017_2000025464-v03
This document and the information therein are the property of Morpho. They must not
be copied or communicated to a third party without the prior authorization of Morpho
416
July 17
Time and Attendance configuration through Webserver
Access Path
Webserver > Terminal Settings > Time and Attendance
Screens & Steps
Figure 343:
Normal Time and Attendance mode
1.
Click on Enable Time and Attendance, for enabling this mode
Click on Mandatory Use of Function Keys. On enabling this, terminal will pop up T&A screen
every time after user presents fingerprint. If mandatory is not selected, then user can select
T&A option before
Message Timeout: an administrator can define the duration for which access result is displayed
on the LCD screen of the terminal
Key Select Timeout: an administrator can define a duration for which F key selection option will
be displayed. If user does not input the key, then access is denied (in case T&A is mandatory).
Valid range of timeout is 1 to 60 seconds.
Active Key Timeout: within this duration the key should be pressed, if operation failed first time.
Valid range of timeout is 1 to 60 seconds.
Select User Control Mode as “TNA before user control”, it means user have to first select a T&A
action before user control; or “TNA after user control”, it means user have to select TNA action
after user control (such as entering biometric/pin data).
Select Displayed Mode as “Text mode” or “Icon Mode”. By default text is selected. If an
administrator select “Icon mode”, than instead of F key with text, icons are displayed, refer
“Time and Attendance UI in Normal mode with Icon”.