MorphoAccess® SIGMA Series - Administrator Guide
Access Control by Authentication
2017_2000025464-v03
This document and the information therein are the property of Morpho. They must not
be copied or communicated to a third party without the prior authorization of Morpho
378
July 17
Authentication with local database: ID input from Wiegand
or Clock & Data
Description
This mode requires an external card reader that will send the User ID to authenticate to the
MorphoAccess® SIGMA Family terminal through Wiegand or Clock & Data input.
The default screen invites the user to pass his badge so the external reader sends the User ID to the
terminal’s Wiegand or Clock & Data input. If the ID exists in the database, the terminal performs an
authentication using the biometric templates associated to this ID.
If the authentication is successful, the terminal triggers the access or returns the User ID to the
Central Access Controller.
Once the user authentication is done, terminal automatically loops back and waits for a new
input ID. If the identifier sent by the reader is not present in the local database, authentication
is not launched.
Activation key
The activation of this mode is controlled by following parameter:
Parameter name
Value
Description
ucc.trigger_event
1 to 15
Use this parameter to enable finger,
contactless, keypad and external port
trigger. Only when external port trigger
is enabled, the terminal would receive
trigger from Wiegand or Clock & Data.
Set ‘8’ to enable External Port
Note: Set Trigger Event through
“Configure Trigger Events” through
Terminal.
wiegand.external_port_input_type
0 or 1
Storing current external port input type
as:
Set ‘0’ for Wiegand format input
(default)
Set ‘1’ for Clock & Data format
input
wiegand.external_port_output_status 0, 1 or 2
To enable/disable Wiegand output
functionality.