6.6.6 Reset LRF module to default settings >LM,Rd*<CS><CR>
This command resets all LRF module’s configuration parameters to their default values.
An automatic restart of the LRF module is performed during the process.
Default parameters are:
Baud rate
57600
Range gate max
30000
Range gate min
00000
Timestamp
deactivated
Reset LRF module settings command and response
Command
Inputs
Description
>LM,Rd*<CS><CR>
>LM,Rd*7B
<0D>
Reset LRF module to default settings.
Example.
Response
Outputs
Description
No response expected.
Table 19: Reset LRF module settings command
Example of a reset LRF module to default settings command transaction:
Host
LRF Module
Command frame:
>LM,Rd*7B
<0D>
LRF Module
Host
Acknowledge frame:
>AC*84
<0D>
Prompt:
<