background image

 
Copyright© 2018 - Saflec Systems (Pty) Ltd. 

www.saflecsystems.co.za 

 

SSI-302-W 

Isolated Wiegand interface board 

Revision 1.0 - (April 13, 2018) 

 
 

Advanced settings guide

 

 
Introduction 

For basic installation and configuration of the Isolated Wiegand interface board, please refer to the Quickstart 
guide. 

 
 
 
 
 
 
 
 
 
Figure 1 

SSI-302-W with feature labels 

 

The status display and the config button are used together to configure various settings on the device. 
Long-pressing mentioned below is pressing and holding the config button in until something happens. 

 

RS-485 Address 

The address is a fairly straightforward setting. By default the address of the unit 
will be shown on the Wiegand board. To change this: 

1)  Long-press the button (2 seconds) until the address starts flashing. 
2)  Now every time you single press the button the address will cycle 

between 0 and F (0-15). 

Addresses A-F represent the hexadecimal value for 10 to 15, so A=10, 
B=11, C=12 etc. 

3)  When you long-press the button (2 seconds) again, the new address setting will be saved and the 

reader will reboot and use the new setting. Leaving for 15 seconds cancels the change. 

 

How to change advanced settings 

There are a few advanced settings that can be changed on the reader and these are a little more 
complicated to set. The basic steps are: 

1)  If you long-press the button, the LED display starts cycling clockwise, 

then after a while will start cycling ANTI-clockwise. This indicates that you 
are entering the advanced configuration section. Release the button. 

2)  When configuring the advanced settings the decimal point next to the 

number becomes important to pay attention to. The display toggles 
between setting index and value. When it is turned ON, then the number 
being shown is the index of the setting, when OFF, then the value of the 
setting is being shown. 

3)  Pressing the button will cycle through the various settings. 
4)  Long-pressing will start edit the current setting. 
5)  Pressing will now change the setting by cycling through the available values. 
6)  Long-pressing will save the changes to that setting. 
7)  When complete, long-press the button until it starts cycling again, then release. 

 
 
 
 
Figure 2 

The LED display 

‘cycling’ 

clockwise 

 
 
 
 
Figure 3 

The LED display 

‘cycling’ 

anti-clockwise 

Отзывы: