background image

SDC-650 Multiple door controller 

Step 7: Connecting the digital outputs 

 

 

Copyright© 2015 

– Saflec Systems (Pty) Ltd. 

http://www.saflecsystems.co.za 

 

Step 5b: (Optional) Connect the RS-232 Host interface 

As discussed in 5a this step is necessary if the controller is to be linked to the Host using the RS-
232. This step is unnecessary if the controller uses the RS-485 to another controller that is linked 
to the host or if the Ethernet interface is being used. 

 
 
 
 
 
 
 
 
 
 
 
Figure 9 

RS-232 wiring configuration for the PC host interface 

Step 6: Connecting the digital inputs 

Before wiring the digital inputs make sure that the power is switched off on the controller board. 
When looking at the controller board with the power connector on the top right of the board, the 
inputs are arranged in ascending order from left to right with a shared common between each 
input pair. See the diagram below on how to correctly wire them. 
 

 
 
 
 
 
 
 
Figure 10 

Example wiring of inputs 0 and 1 to a pushbutton and closed sensor 

Step 7: Connecting the digital outputs 

Before wiring the digital inputs make sure that the power is switched off on the controller board. 
When looking at the controller board with the power connector to the right, the outputs are 
arranged in ascending order from left to right. 

 

 

The outputs can provide 12Vdc power, or simply act as a potential free contact, allowing external 
DC or AC power to be switched through the relay.  
 
The configuration of this output mode can be accomplished using the jumpers J11 to J15. 
Possible output modes are listed below. 

Содержание SDC-650

Страница 1: ...nputs Up to 16 SDC controllers can be linked using a protected RS 485 network The PC can connect to it using either RS 232 or the built in Ethernet connector or through the RS 485 network from another...

Страница 2: ...SDC 650 Multiple door controller 2 Introduction Copyright 2015 Saflec Systems Pty Ltd http www saflecsystems co za Figure 2 Possible position for an SDC 650 in a SACS access control system...

Страница 3: ...wer the panel will be active If the screen is blank it will be in screen saving mode Tapping any button will awaken the screen and allow you to configure the device Figure 3 The configuration and diag...

Страница 4: ...ations network Each controller on this network requires a unique address for communications and identification Duplicate addresses will cause communication problems The address of the controller can b...

Страница 5: ...and last controller on the line by shorting J6 Controllers in the middle of the line must not have the termination jumper inserted as this can cause network problems In the diagram above you will see...

Страница 6: ...mmunicate with the host system This can be done through either the Ethernet connection or the RS 232 connection The Ethernet cable is a non power over Ethernet cable to an RJ 45 plug The typical wirin...

Страница 7: ...at the controller board with the power connector on the top right of the board the inputs are arranged in ascending order from left to right with a shared common between each input pair See the diagra...

Страница 8: ...for the output relays Figure 12 Example wiring for an externally powered magnetic lock Normally closed Output mode 2 Internally powered outputs To set the output to internally powered mode place two j...

Страница 9: ...loads such as strike locks care should be taken to prevent a back EMF voltage spike In order to do this a freewheeling diode also known as flyback diode should be connected across the load as seen in...

Страница 10: ...Figure 16 The Web interface front page It shows basic diagnostics information on the main page but the links at the bottom will require a username and password for authentication The default username...

Страница 11: ...contact Maximum voltage AC 250Vac Maximum voltage DC 220Vdc Internally powered Outputs Maximum combined current 3 7A Recommended maximums per relay 750mA at 12Vdc Externally powered Outputs Recommende...

Страница 12: ...SDC 650 Multiple door controller 12 Copyright 2015 Saflec Systems Pty Ltd http www saflecsystems co za Notes...

Отзывы: